ENTRY D0753 20141210 D096D075300000001 SUBENT D0753001 20141210 D096D075300100001 BIB 11 32 D075300100002 TITLE Accurate measurements of the 63Cu(d,p)64Cu and D075300100003 natCu(d,x)65Zn cross- sections in the 2.77-5.62 MeV D075300100004 energy range D075300100005 AUTHOR (L.Weissman, A.Kreisel, T.Hirsh, O.Aviv, D.Berkovits, D075300100006 O.Girshevitz, Y.Eisen) D075300100007 INSTITUTE (3ISLSOR) D075300100008 (3ISLISL) The Institute for Nanotechnology, Bar-Ilan D075300100009 University, Ramat-Gan 52900, Israel D075300100010 REFERENCE (J,NIM/B,342,7,2015) D075300100011 #doi:10.1016/j.nimb.2014.09.002 D075300100012 FACILITY (LINAC,3ISLSOR) Soreq Applied Research Accelerator D075300100013 Facility SARAF Phase I variable energy LINAC D075300100014 INC-SPECT The beam energy was monitored using two methods: D075300100015 1 Time-Of-Flight (TOF), using two phase probes at the D075300100016 SARAF diagnostic plate; D075300100017 2 Detection of deuterons Rutherford Backscattered D075300100018 from a thin gold foil D075300100019 SAMPLE Natural copper evaporated on a 12.5 um thick Mylar D075300100020 sheet. A typical thickness of the surface copper D075300100021 oxide and the copper layers was of 0.016 and 0.218 um, D075300100022 respectively D075300100023 METHOD (SITA) D075300100024 (BCINT) Typical beam currents used during the D075300100025 irradiations were in the range of 250-300 nA. D075300100026 REL-REF (R,,R.B.Firestone,B,FIRESTONE,,1996) Decay data. D075300100027 ERR-ANALYS (EN-ERR) Error on beam energy D075300100028 (ERR-T) The total uncertainties determined from the D075300100029 following partial uncertainties. D075300100030 (ERR-1) target thickness 1% D075300100031 (ERR-2) beam charge collection measurements 1% D075300100032 statistical errors of the gamma peaks integration D075300100033 HISTORY (20141210C) VS D075300100034 ENDBIB 32 0 D075300100035 COMMON 4 3 D075300100036 EN-RSL-FW EN-ERR ERR-1 ERR-2 D075300100037 KEV KEV PER-CENT PER-CENT D075300100038 25. 50. 1. 1. D075300100039 ENDCOMMON 3 0 D075300100040 ENDSUBENT 39 0 D075300199999 SUBENT D0753002 20141210 D096D075300200001 BIB 6 12 D075300200002 REACTION (29-CU-63(D,P)29-CU-64,,SIG) D075300200003 DECAY-DATA (29-CU-64,12.7HR,DG,1345.8,0.0047) D075300200004 METHOD (ACTIV) Measurement start 1-2 days after irradiation. D075300200005 The measurement time between 1 and 10 h. Dead time of D075300200006 the measurement was below 2.5%. D075300200007 DETECTOR (HPGE) 60% relative efficiency HPGe detector at Soreq D075300200008 NRC low-background measuring facility. The samples wereD075300200009 placed at distances 5 or 20 cm from the detector. D075300200010 The efficiencies for detection of the 1345.8 keV were D075300200011 0.83% and 0.11% for 5 and 20 cm distances. D075300200012 ERR-ANALYS (ERR-3) detector efficiency 2.15% D075300200013 STATUS (TABLE) Table 1 of Nucl. Instr. and Meth. B342 (2015) 7D075300200014 ENDBIB 12 0 D075300200015 COMMON 1 3 D075300200016 ERR-3 D075300200017 PER-CENT D075300200018 2.15 D075300200019 ENDCOMMON 3 0 D075300200020 DATA 3 10 D075300200021 EN DATA ERR-T D075300200022 MEV MB MB D075300200023 5.62 287. 19. D075300200024 5.08 254. 13. D075300200025 4.75 190. 11. D075300200026 4.49 161. 5. D075300200027 4.18 114. 4.5 D075300200028 3.83 77. 2. D075300200029 3.56 52. 1.5 D075300200030 3.33 23. 1. D075300200031 3.03 18. 0.5 D075300200032 2.77 6.5 0.2 D075300200033 ENDDATA 12 0 D075300200034 ENDSUBENT 33 0 D075300299999 SUBENT D0753003 20141211 D096D075300300001 BIB 6 12 D075300300002 REACTION (29-CU-0(D,X)30-ZN-65,,SIG) D075300300003 DECAY-DATA (30-ZN-65,244.26D,DG,1115.5,0.502) D075300300004 DETECTOR A special low-background system consisting of a 70% D075300300005 relative efficiency HPGe detector from ORTEC and a D075300300006 plastic scintillator from Saint-Gobain for cosmic ray D075300300007 veto suppression. The samples placed at 2 mm from the D075300300008 detector. The efficiency for detection of the 1115.5 D075300300009 keV gamma was 3.8% at this distance. D075300300010 METHOD (ACTIV) Measurement start 1-2 months after irradiation.D075300300011 The measurement time 102 days. D075300300012 STATUS (TABLE) Table 2 of Nucl. Instr. and Meth. B342 (2015) 7D075300300013 ERR-ANALYS (ERR-4) detector efficiency 3% D075300300014 ENDBIB 12 0 D075300300015 COMMON 1 3 D075300300016 ERR-4 D075300300017 PER-CENT D075300300018 3. D075300300019 ENDCOMMON 3 0 D075300300020 DATA 3 10 D075300300021 EN DATA ERR-T D075300300022 MEV MB MB D075300300023 5.62 31.4 2.2 D075300300024 5.08 7.2 0.25 D075300300025 4.75 1.3 0.05 D075300300026 4.49 0.135 0.02 D075300300027 4.18 0.12 0.01 D075300300028 3.83 0.069 0.007 D075300300029 3.56 0.042 0.006 D075300300030 3.33 0.033 0.004 D075300300031 3.03 0.016 0.003 D075300300032 2.77 0.009 0.002 D075300300033 ENDDATA 12 0 D075300300034 ENDSUBENT 33 0 D075300399999 ENDENTRY 3 0 D075399999999