ENTRY D0763 20150113 D097D076300000001 SUBENT D0763001 20150113 D097D076300100001 BIB 8 13 D076300100002 TITLE Application of PIXE in the determination of the D076300100003 production cross section of a radionuclide decaying D076300100004 by electron capture D076300100005 AUTHOR (J.R.Morales, M.A.Chesta, S.A.Cancino, P.A.Miranda, D076300100006 M.I.Dinator, M.J.Avila) D076300100007 INSTITUTE (3CHLSAN,3CHLCEC) D076300100008 REFERENCE (J,NIM/B,227,385,2005) D076300100009 FACILITY (VDG,3CHLSAN) Van de Graaff KN3750 HVE accelerator D076300100010 METHOD (BCINT) Proton flux determined by Faraday cup D076300100011 (ACTIV) Irradiated for 889.4 min to collect 47.1 mC. D076300100012 STATUS (TABLE) Table 1 of Nucl.Instrum.Meth.B227(2005)385 D076300100013 (APRVD) Approved by Jose Roberto Morales (2015-01-22) D076300100014 HISTORY (20150113C) On D076300100015 ENDBIB 13 0 D076300100016 NOCOMMON 0 0 D076300100017 ENDSUBENT 16 0 D076300199999 SUBENT D0763002 20150113 D097D076300200001 BIB 6 21 D076300200002 REACTION 1(29-CU-63(D,P)29-CU-64,,SIG) D076300200003 2(29-CU-63(D,P)29-CU-64,,SIG) D076300200004 SAMPLE (29-CU-63,NAT=0.6917) D076300200005 Thin Cu (2.4 um thick, atomic surface density of D076300200006 1.416E+19 atoms/cm2 for 63Cu) D076300200007 DECAY-DATA1(29-CU-64,12.7HR,EC,,0.431, D076300200008 XR,7.477) D076300200009 EC branching ratios to 2+ (0.471%) and to 0+ (42.63%) D076300200010 in article was summed by the compiler. D076300200011 2(29-CU-64,12.7HR,DG,1346.,0.00471) D076300200012 METHOD 1(XSPEC) Cooled for 26 min, and measured for 120 min D076300200013 2(GSPEC) Cooled for 198 min, and measured for 6.5*T1/2. D076300200014 DETECTOR 1(SILI) 220 eV (FWHM) resolution at 5.9 keV D076300200015 2(HPGE) D076300200016 ERR-ANALYS (DATA-ERR) The following sources are considered: D076300200017 1.Experimental parameters, e.g., beam energy, D076300200018 irradiation time, ion flux, counting statistics, D076300200019 time lag between EOB and start counting (2%)D076300200020 2.Target thickness, proton ionization cross section, D076300200021 decay constant, branching ratio, HPGe detector D076300200022 efficiency (7%)D076300200023 ENDBIB 21 0 D076300200024 NOCOMMON 0 0 D076300200025 DATA 5 1 D076300200026 EN DATA 1DATA-ERR 1DATA 2DATA-ERR 2 D076300200027 MEV MB PER-CENT MB PER-CENT D076300200028 2.4 1.39 9.8 1.38 8.8 D076300200029 ENDDATA 3 0 D076300200030 ENDSUBENT 29 0 D076300299999 ENDENTRY 2 0 D076399999999