ENTRY D0895 20180306 D115D089500000001 SUBENT D0895001 20180306 D115D089500100001 BIB 10 16 D089500100002 TITLE Energy and mass distributions of induced-fission of D089500100003 Au-197 nucleus by 29 MeV protons D089500100004 AUTHOR (S.Soheyli) D089500100005 INSTITUTE (3IRNIRN) Bu-Ali Sina University, Hamadan D089500100006 REFERENCE (J,CPL,24,1525,2007) D089500100007 #doi:10.1088/0256-307X/24/6/026 D089500100008 FACILITY (CYCLO,3IRNKRJ) cyclone 30. D089500100009 INC-SOURCE Beam current was kept below 50 nA. D089500100010 DETECTOR (SIBAR) Two collimated surface barrier detectors with D089500100011 registration areas 100 mm2 and 300 mm2 respectively D089500100012 were used. D089500100013 SAMPLE Self-supporting 340 mu-g/cm2 thick Au-197 target was D089500100014 used. D089500100015 METHOD (BCINT) D089500100016 (COINC) Two coincident fission fragments were measured.D089500100017 HISTORY (20180306C) SS+On D089500100018 ENDBIB 16 0 D089500100019 COMMON 2 3 D089500100020 EN EN-ERR D089500100021 MEV MEV D089500100022 29.0 0.5 D089500100023 ENDCOMMON 3 0 D089500100024 ENDSUBENT 23 0 D089500199999 SUBENT D0895002 20180306 D115D089500200001 BIB 3 3 D089500200002 REACTION (79-AU-197(P,F)MASS,SEC,FY) D089500200003 ERR-ANALYS (DATA-ERR) No source of uncertainty is given. D089500200004 STATUS (CURVE) Figure 2. D089500200005 ENDBIB 3 0 D089500200006 COMMON 1 3 D089500200007 ERR-DIG D089500200008 PC/FIS D089500200009 0.062 D089500200010 ENDCOMMON 3 0 D089500200011 DATA 3 9 D089500200012 MASS DATA DATA-ERR D089500200013 NO-DIM PC/FIS PC/FIS D089500200014 79. 5.339 0.800 D089500200015 84. 16.409 0.800 D089500200016 89. 21.079 0.933 D089500200017 94. 31.216 1.600 D089500200018 99. 39.353 2.000 D089500200019 104. 34.023 1.733 D089500200020 109. 28.826 1.467 D089500200021 114. 17.630 0.933 D089500200022 119. 5.900 0.800 D089500200023 ENDDATA 11 0 D089500200024 ENDSUBENT 23 0 D089500299999 SUBENT D0895003 20180306 D115D089500300001 BIB 4 9 D089500300002 REACTION (79-AU-197(P,F),,SIG) D089500300003 ANALYSIS (INTAD) The number of fission fragments were measured D089500300004 at 30, 60, 90 degr and fitted to Legendre polynomials. D089500300005 ERR-ANALYS (ERR-1) Integrated beam uncertainty. D089500300006 (ERR-2) Target thickness uncertainty. D089500300007 (ERR-3) Detector solid angle uncertainty. D089500300008 (ERR-S) Uncertainty in number of fission events D089500300009 (DATA-ERR) No source of uncertainty is given. D089500300010 STATUS (TABLE) Table 1. D089500300011 ENDBIB 9 0 D089500300012 NOCOMMON 0 0 D089500300013 DATA 6 1 D089500300014 DATA DATA-ERR ERR-1 ERR-2 ERR-3 ERR-S D089500300015 MICRO-B MICRO-B PER-CENT PER-CENT PER-CENT PER-CENT D089500300016 25. 1.8 6. 6. 3. 9.D089500300017 ENDDATA 3 0 D089500300018 ENDSUBENT 17 0 D089500399999 SUBENT D0895004 20180306 D115D089500400001 BIB 4 5 D089500400002 REACTION (79-AU-197(P,F),,AKE,LF+HF) D089500400003 Average total kinetic energy. D089500400004 MISC-COL (MISC) Dispersion of the energy distribution. D089500400005 ERR-ANALYS (MISC-ERR) Error of dispersion of energy distribution. D089500400006 STATUS (TABLE) Table 1. D089500400007 ENDBIB 5 0 D089500400008 NOCOMMON 0 0 D089500400009 DATA 3 1 D089500400010 DATA MISC MISC-ERR D089500400011 MEV MEV-SQ MEV-SQ D089500400012 136.7 57.7 4.0 D089500400013 ENDDATA 3 0 D089500400014 ENDSUBENT 13 0 D089500499999 ENDENTRY 4 0 D089599999999