ENTRY D4330 20160921 D106D433000000001 SUBENT D4330001 20160921 D106D433000100001 BIB 9 24 D433000100002 TITLE Three New Low-Energy Resonances in the 22Ne(p,g)23Na D433000100003 Reaction D433000100004 AUTHOR (F.Cavanna,R.Depalo,M.Aliotta,M.Anders,D.Bemmerer, D433000100005 A.Best,A.Boeltzig,C.Broggini,C.G.Bruno,A.Caciolli, D433000100006 P.Corvisiero,T.Davinson,A.di Leva,Z.Elekes,F.Ferraro, D433000100007 A.Formicola,Zs.Fulop,G.Gervino,A.Guglielmetti, D433000100008 C.Gustavino,Gy.Gyurky,G.Imbriani,M.Junker,R.Menegazzo, D433000100009 V.Mossa,F.R.Pantaleo,P.Prati,D.A.Scott,E.Somorjai, D433000100010 O.Straniero,F.Strieder,T.Szucs,M.P.Takacs,D.Trezzi) D433000100011 The LUNA Collaboration D433000100012 INSTITUTE (2ITYGVA,2ITYPAD,2UK EDG,2GERZFK,2GERDRE,2ITYLGS, D433000100013 2ITYNAP,3HUNDEB,2ITYTUR,2ITYMIL,2ITYBAU,2GERBOC) D433000100014 (2ITYITY) INFN Sezione di Roma La Sapienza, Roma D433000100015 REFERENCE (J,PRL,115,252501,2015) D433000100016 #doi:10.1103/PhysRevLett.115.252501 D433000100017 FACILITY (CCW,2ITYLGS) at LUNA II facility, located at the D433000100018 Gran Sasso National Laboratory using a high-current D433000100019 400-kV, Cockroft-Walton type accelerator D433000100020 SAMPLE (10-NE-22,ENR=0.999) Ne-22 gas, isotopic composition D433000100021 99.9%, 1.5 mbar in a windowless gas chamber was used. D433000100022 METHOD (SITA) D433000100023 DETECTOR (HPGE) low background, Pb-Cu shielding, at 55 and 90 D433000100024 degree. D433000100025 HISTORY (20160921C) MPT D433000100026 ENDBIB 24 0 D433000100027 NOCOMMON 0 0 D433000100028 ENDSUBENT 27 0 D433000199999 SUBENT D4330002 20160921 D106D433000200001 BIB 3 13 D433000200002 REACTION (10-NE-22(P,G),,WID/STR) Measured the 440 keV D433000200003 gamma ray deexcitation of the first excited state D433000200004 in 23Na. D433000200005 ERR-ANALYS (EN-RES-ERR) Includes 1.7% uncertainty on the proton D433000200006 energy loss in the gas target. Initial uncertainty D433000200007 0.3KeV. D433000200008 (ERR-T).The following systematic and statistical D433000200009 uncertainties were considered: D433000200010 (ERR-1).The error in detector efficiency D433000200011 (ERR-2).Gas density D433000200012 (ERR-3).The error in beam current D433000200013 (ERR-S,3.,14.).Statistical error D433000200014 STATUS (TABLE) Table I of Phys.Rev.Lett.115(2015)252501 D433000200015 ENDBIB 13 0 D433000200016 COMMON 3 3 D433000200017 ERR-1 ERR-2 ERR-3 D433000200018 PER-CENT PER-CENT PER-CENT D433000200019 3.0 1.1 1. D433000200020 ENDCOMMON 3 0 D433000200021 DATA 5 6 D433000200022 EN-RES EN-RES-ERR DATA ERR-T DATA-MAX D433000200023 KEV KEV EV EV EV D433000200024 71. 1.5E-9 D433000200025 105. 7.6E-9 D433000200026 156.2 0.7 1.48E-7 0.1E-7 D433000200027 189.5 0.7 1.87E-6 0.06E-6 D433000200028 215. 2.8E-8 D433000200029 259.7 0.6 6.89E-6 0.16E-6 D433000200030 ENDDATA 8 0 D433000200031 ENDSUBENT 30 0 D433000299999 ENDENTRY 2 0 D433099999999