ENTRY D6088 20100222 D072D608800000001 SUBENT D6088001 20100222 D072D608800100001 BIB 11 37 D608800100002 TITLE Spin and excitation energy dependence of fission D608800100003 survival for the 19F+175Lu system D608800100004 AUTHOR (S.K.Hui,C.R.Bhuinya,A.K.Ganguly,N.Madhavan,J.J.Das, D608800100005 P.Sugathan,D.O.Kataria,S.Murlithar,Lagy T.Baby, D608800100006 Vandana Tripathi,Akhil Jhingan,A.K.Sinha, D608800100007 P.V.Madhusudhana Rao,N.V.S.V.Prasad,A.M.Vinodkumar, D608800100008 R.Singh,M.Thoennessen,G.Gervais) D608800100009 INSTITUTE (3INDNSD,3INDCAU,3INDDLH,1USAMSU) D608800100010 REFERENCE (J,PR/C,62,054604,2000) D608800100011 FACILITY (VDG,3INDNSD)15UD Pelletron at the IUAC,New Delhi D608800100012 SAMPLE 200 mu-g/cm2 natLu target on 250 mu-g/cm2 Al backing D608800100013 DETECTOR (HPGE,BGO)The Gamma-ray ER coincidences were mea- D608800100014 sured using first a high resolution HPGe detector and D608800100015 subsequently with an array of 14 BGO detectors. The D608800100016 HPGe data were used to determine the absolute ER D608800100017 detection efficiencies of HIRA which were in D608800100018 agreement with those extracted from the measured D608800100019 charge, energy, and angular distributions of ER. D608800100020 The BGO array was used to measure Gamma-ray fold D608800100021 distribution in coincidence with the ER at the D608800100022 focal plane. D608800100023 METHOD (GSPEC,ASEP)-All the measurements utilized the D608800100024 sliding seal target chamber of the recoil mass D608800100025 separator HIRA (Heavy Ion Recoil Analyser) with the D608800100026 chamber modified with special bucket structures from D608800100027 top and bottom plates to accommodate Gamma detectors D608800100028 in close geometry. A thin carbon foil was used for D608800100029 charge-state reequilibration before the recoiling D608800100030 ER enter HIRA. D608800100031 ERR-ANALYS (EN-ERR-DIG) Digitized error D608800100032 (ERR-DIG) Digitized error D608800100033 (DATA-ERR) Nothing said about uncertainties D608800100034 STATUS (UNOBT) request was sent to corresponding author D608800100035 HISTORY (20091105C) Arif Patel,Hemang P.Jani,Nikit D608800100036 N.Deshmukh, Paresh M.Prajapati-The M.S.University D608800100037 of Baroda,Vadodara,Gujarat,India.-nikitdesh@yahoo.com D608800100038 (20100222A) On. 002 corrected. D608800100039 ENDBIB 37 0 D608800100040 NOCOMMON 0 0 D608800100041 ENDSUBENT 40 0 D608800199999 SUBENT D6088002 20100222 D072D608800200001 BIB 4 9 D608800200002 REACTION 1(71-LU-175(9-F-19,FUS),,SIG) D608800200003 2(71-LU-175(9-F-19,FUS),,SIG,ER) D608800200004 Fusion cross sections are obtained by adding the D608800200005 fission and measured evaporation residue cross sectionsD608800200006 REL-REF (R,,A.Chatterjee+,C,96PANTNG,,170,1996) D608800200007 Proceedings of the Department of Atomic Energy D608800200008 Symposium on Nuclear Physics, 1996, Vol. 39B, p.170. D608800200009 STATUS (CURVE)Data has been digitized from Fig.1 D608800200010 HISTORY (20100222A) On. SF7: ER moved from SF8 D608800200011 ENDBIB 9 0 D608800200012 COMMON 2 3 D608800200013 EN-ERR-DIG ERR-DIG D608800200014 MEV PER-CENT D608800200015 0.05 0.2 D608800200016 ENDCOMMON 3 0 D608800200017 DATA 5 13 D608800200018 EN DATA 1DATA-ERR 1DATA 2DATA-ERR 2 D608800200019 MEV MB MB MB MB D608800200020 90.00 228.48 21.759 198.73 7.3647 D608800200021 97.992 413.98 15.341 D608800200022 100.00 518.12 52.795 511.90 22.199 D608800200023 110.00 768.51 78.309 511.90 22.199 D608800200024 115.00 905.26 86.212 543.91 30.513 D608800200025 117.43 515.03 22.335 D608800200026 120.00 961.88 94.227 487.68 18.072 D608800200027 122.43 426.77 15.815 D608800200028 125.00 1009.7 104.42 406.56 17.631 D608800200029 129.96 450.72 25.285 D608800200030 132.50 362.32 22.653 D608800200031 135.00 1105.9 108.34 336.90 23.647 D608800200032 139.00 1066.4 110.28 232.72 11.569 D608800200033 ENDDATA 15 0 D608800200034 ENDSUBENT 33 0 D608800299999 ENDENTRY 2 0 D608899999999