ENTRY D6117 20120208 D082D611700000001 SUBENT D6117001 20120208 D082D611700100001 BIB 11 32 D611700100002 TITLE Evaporation residue excitation function measurement forD611700100003 the 16O + 194Pt reaction D611700100004 AUTHOR (E.Prasad, K.M.Varier, N.Madhavan, S.Nath, D611700100005 J.Gehlot, Sunil Kalkal, Jhilam Sadhukhan, G.Mohanto, D611700100006 P.Sugathan, A.Jhingan, B.R.S.Babu, T.Varughese, D611700100007 K.S.Golda, B.P.Ajith Kumar, B.Satheesh, D611700100008 Santanu Pal, R.Singh, A.K.Sinha, S.Kailas) D611700100009 REFERENCE (J,PR/C,84,064606,2011) D611700100010 #doi:10.1103/PhysRevC.84.064606 D611700100011 INSTITUTE (3INDDLH,3INDNSD,3INDVEC,3INDTRM) D611700100012 (3INDIND) Univ. of Calicut, UGC-DAE CSR Kalkata Centre D611700100013 FACILITY (VDGT,3INDNSD) 15 UD pelletron facility at IUAC D611700100014 SAMPLE (78-PT-194,ENR=0.965) D611700100015 Isotopically enriched (96.5%) 194Pt target of thicknessD611700100016 300 ug/cm2 on a 20 ug/cm2 thick carbon backing D611700100017 METHOD (ASEP) Experiment carried using Hybrid Recoil Mass D611700100018 Analyser (HYRA) set-up; a dual-mode, dual-stage D611700100019 recoil mass separator and spectrometer. D611700100020 ERs produced separated from the intense beam D611700100021 background and collected at the focal plane detector.D611700100022 DETECTOR (MWPC,SOLST) Focal plane detectors: MWPC with an activeD611700100023 area of 57x57 mm2 (operated with isobutane gas of D611700100024 about 2 mbar pressure) followed by a two-dimensional D611700100025 position-sensitive silicon detector with an active D611700100026 area of 50x50 mm2 D611700100027 MONITOR (78-PT-194(8-O-16,EL)78-PT-194,,DA,,RTH) D611700100028 ERR-ANALYS (DATA-ERR) The overall errors in the estimated D611700100029 cross sections are <=20%, output which the D611700100030 transmission efficiency of HYRA contributes the D611700100031 maximum. D611700100032 HISTORY (20120202C) Maninder Kaur, Panjab Univ., Chandigarh D611700100033 (20120208U) On. Finalized D611700100034 ENDBIB 32 0 D611700100035 COMMON 1 3 D611700100036 ANG-NRM D611700100037 ADEG D611700100038 22. D611700100039 ENDCOMMON 3 0 D611700100040 ENDSUBENT 39 0 D611700199999 SUBENT D6117002 20120208 D082D611700200001 BIB 3 5 D611700200002 REACTION (78-PT-194(8-O-16,FUS),,SIG,ER) D611700200003 STATUS (TABLE)Table III of Phys.Rev.C84(2011)064606 D611700200004 MISC-COL (MISC) the percentage transmission efficiency of HYRA, D611700200005 for the focal plane detector at different beam D611700200006 energies and the corresponding uncertainties D611700200007 ENDBIB 5 0 D611700200008 NOCOMMON 0 0 D611700200009 DATA 5 8 D611700200010 EN-CM DATA DATA-ERR MISC MISC-ERR D611700200011 MEV MB MB SEE TEXT SEE TEXT D611700200012 69.7 5.5 0.9 D611700200013 73.5 54.0 9.0 1.53 0.21 D611700200014 77.3 168.1 29.0 1.54 0.23 D611700200015 81.1 214.0 38.1 1.56 0.23 D611700200016 84.9 218.0 33.0 1.58 0.24 D611700200017 88.7 241.0 39.0 1.60 0.24 D611700200018 93.4 218.0 33.2 1.64 0.25 D611700200019 95.2 175.0 31.0 1.65 0.25 D611700200020 ENDDATA 10 0 D611700200021 ENDSUBENT 20 0 D611700299999 ENDENTRY 2 0 D611799999999