ENTRY E1118 20080131 E049E111800000001 SUBENT E1118001 20080131 E049E111800100001 BIB 13 24 E111800100002 TITLE Analyzing power as a probe for clarifying nuclear E111800100003 reaction mechanisms: Study of the two-step unbound E111800100004 channel contribution E111800100005 AUTHOR (K.Yagi, Y.Aoki, K.Hashimoto, H.Iida, H.Sakamoto, E111800100006 Y.Tagishi, M.Matoba, M.Igarashi, K.-I.Kubo) E111800100007 INSTITUTE (2JPNTSU) Institute for Physics and Tandem Accelerator E111800100008 Center E111800100009 (2JPNKYU) Department of Energy Conversion Engineering E111800100010 (2JPNJPN) Tokyo Medical College, Tokyo E111800100011 (2JPNTMU) Department of Physics E111800100012 REFERENCE (J,PR/C,31,(2),676,198502) E111800100013 PART-DET (T) E111800100014 EN-SEC (E-LVL,82-PB-206) E111800100015 LEVEL-PROP (82-PB-206,E-LVL=1.34,SPIN=3.,PARITY=+1.) E111800100016 SAMPLE - Target enrichment is 99.1%. E111800100017 - Chemical-form of target is element. E111800100018 - Physical-form of target is solid. E111800100019 - Target is self supported. E111800100020 FACILITY (CYCLO,2JPNOSA) Research Center for Nuclear Physics E111800100021 DETECTOR (MAGSP) To detect emitted tritons (RAIDEN) E111800100022 ADD-RES (COMP) DWBA (Distorted wave Born approximation) (Code E111800100023 TWOFNR/PTFF) E111800100024 STATUS (CURVE) Scanned from Fig.1, p677 in reference E111800100025 HISTORY (20070509T) On. Converted from NRDF D1118 E111800100026 ENDBIB 24 0 E111800100027 COMMON 1 3 E111800100028 E-LVL E111800100029 MEV E111800100030 1.34 E111800100031 ENDCOMMON 3 0 E111800100032 ENDSUBENT 31 0 E111800199999 SUBENT E1118002 20080131 E049E111800200001 BIB 6 8 E111800200002 REACTION (82-PB-208(P,T)82-PB-206,PAR,POL/DA,,ANA) E111800200003 EN-SEC ANG is polar angle between beam and triton in E111800200004 laboratory system E111800200005 INC-SOURCE Beam intensity is 15 nA. E111800200006 (POLIS) E111800200007 SAMPLE Target-thickness is 2.6 mg/cm**2. E111800200008 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E111800200009 HISTORY (20070619A) At. Re-digitized E111800200010 ENDBIB 8 0 E111800200011 COMMON 2 3 E111800200012 EN POL-BM E111800200013 MEV NO-DIM E111800200014 34.8 0.78 E111800200015 ENDCOMMON 3 0 E111800200016 DATA 3 10 E111800200017 ANG DATA DATA-ERR E111800200018 ADEG NO-DIM NO-DIM E111800200019 5.066E+00 2.301E-01 5.588E-02 E111800200020 7.910E+00 2.578E-01 7.547E-02 E111800200021 1.037E+01 3.247E-01 4.757E-02 E111800200022 1.512E+01 1.706E-01 6.149E-02 E111800200023 2.052E+01 6.113E-02 6.155E-02 E111800200024 2.529E+01 1.882E-02 5.031E-02 E111800200025 3.032E+01 4.444E-03 4.754E-02 E111800200026 3.546E+01 -1.134E-01 6.149E-02 E111800200027 4.034E+01 -2.479E-01 6.710E-02 E111800200028 4.548E+01 -3.657E-01 7.547E-02 E111800200029 ENDDATA 12 0 E111800200030 ENDSUBENT 29 0 E111800299999 SUBENT E1118003 20080131 E049E111800300001 BIB 5 7 E111800300002 REACTION (82-PB-208(P,T)82-PB-206,PAR,DA) E111800300003 EN-SEC ANG is polar angle between beam and triton in E111800300004 laboratory system E111800300005 INC-SOURCE Beam intensity is 15 nA. E111800300006 (POLIS) E111800300007 SAMPLE Target-thickness is 2.6 mg/cm**2. E111800300008 HISTORY (20070619A) At. Re-digitized E111800300009 ENDBIB 7 0 E111800300010 COMMON 2 3 E111800300011 EN POL-BM E111800300012 MEV NO-DIM E111800300013 34.8 0.78 E111800300014 ENDCOMMON 3 0 E111800300015 DATA 2 9 E111800300016 ANG DATA E111800300017 ADEG MU-B/SR E111800300018 7.531E+00 1.017E+01 E111800300019 9.849E+00 9.660E+00 E111800300020 1.461E+01 8.276E+00 E111800300021 2.000E+01 4.340E+00 E111800300022 2.513E+01 2.600E+00 E111800300023 3.002E+01 2.116E+00 E111800300024 3.504E+01 1.758E+00 E111800300025 4.031E+01 1.227E+00 E111800300026 4.544E+01 7.058E-01 E111800300027 ENDDATA 11 0 E111800300028 ENDSUBENT 27 0 E111800399999 SUBENT E1118004 20080131 E049E111800400001 BIB 6 8 E111800400002 REACTION (82-PB-208(P,T)82-PB-206,PAR,POL/DA,,ANA) E111800400003 EN-SEC ANG is polar angle between beam and triton in E111800400004 laboratory system E111800400005 INC-SOURCE Beam intensity is 80 nA. E111800400006 (POLIS) E111800400007 SAMPLE Target-thickness is 4.0 mg/cm**2. E111800400008 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E111800400009 HISTORY (20070619A) At. Re-digitized E111800400010 ENDBIB 8 0 E111800400011 COMMON 2 3 E111800400012 EN POL-BM E111800400013 MEV NO-DIM E111800400014 50.2 0.83 E111800400015 ENDCOMMON 3 0 E111800400016 DATA 3 7 E111800400017 ANG DATA DATA-ERR E111800400018 ADEG NO-DIM NO-DIM E111800400019 5.204E+00 1.728E-01 5.277E-02 E111800400020 9.975E+00 2.372E-01 5.279E-02 E111800400021 1.480E+01 6.268E-02 4.724E-02 E111800400022 2.041E+01 -1.645E-01 5.002E-02 E111800400023 2.532E+01 -1.640E-01 5.002E-02 E111800400024 3.049E+01 -1.413E-01 4.725E-02 E111800400025 3.551E+01 -1.018E-02 5.000E-02 E111800400026 ENDDATA 9 0 E111800400027 ENDSUBENT 26 0 E111800499999 SUBENT E1118005 20080131 E049E111800500001 BIB 5 7 E111800500002 REACTION (82-PB-208(P,T)82-PB-206,PAR,DA) E111800500003 EN-SEC ANG is polar angle between beam and triton in E111800500004 laboratory system E111800500005 INC-SOURCE Beam intensity is 80 nA. E111800500006 (POLIS) E111800500007 SAMPLE Target-thickness is 4.0 mg/cm**2. E111800500008 HISTORY (20070619A) At. Re-digitized E111800500009 ENDBIB 7 0 E111800500010 COMMON 2 3 E111800500011 EN POL-BM E111800500012 MEV NO-DIM E111800500013 50.2 0.83 E111800500014 ENDCOMMON 3 0 E111800500015 DATA 2 7 E111800500016 ANG DATA E111800500017 ADEG MU-B/SR E111800500018 5.278E+00 3.742E+00 E111800500019 1.048E+01 3.269E+00 E111800500020 1.526E+01 1.899E+00 E111800500021 2.044E+01 1.272E+00 E111800500022 2.587E+01 7.542E-01 E111800500023 3.091E+01 4.471E-01 E111800500024 3.585E+01 3.987E-01 E111800500025 ENDDATA 9 0 E111800500026 ENDSUBENT 25 0 E111800599999 ENDENTRY 5 0 E111899999999