ENTRY E1368 20080131 E051E136800000001 SUBENT E1368001 20080131 E051E136800100001 BIB 10 58 E136800100002 TITLE Tensor interaction in elastic scattering of polarized E136800100003 deuterons from medium-weight nuclei near Ed=22 MeV E136800100004 AUTHOR (M.Takei, Y.Aoki, Y.Tagishi, K.Yagi) E136800100005 INSTITUTE (2JPNTSU) Institute of Physics and Tandem Accelerator E136800100006 Center E136800100007 REFERENCE (J,NP/A,472,(1),41,198709) E136800100008 Main reference. See also TITLE and AUTHOR. E136800100009 (T,TAKEI,198702) M.Takei, Numerical data E136800100010 PART-DET (D) E136800100011 INC-SOURCE Beam intensity is 50 nA. E136800100012 (LAMB) E136800100013 (POLIS) E136800100014 SAMPLE - Chemical-form of target is element. E136800100015 - Physical-form of target is solid. E136800100016 FACILITY (VDGT,2JPNTSU) 12 UD Pelletron at Tandem Accelerator E136800100017 Center E136800100018 ADD-RES E1368.062:20-CA-40(D,EL)20-CA-40 E136800100019 Optical potential parameter E136800100020 See NRDF D1368 DATA,61 for detail. E136800100021 E1368.063:28-NI-58(D,EL)28-NI-58 E136800100022 Optical potential parameter E136800100023 See NRDF D1368 DATA,62 for detail. E136800100024 E1368.064:28-NI-60(D,EL)28-NI-60 E136800100025 Optical potential parameter E136800100026 See NRDF D1368 DATA,63 for detail. E136800100027 E1368.065:28-NI-62(D,EL)28-NI-62 E136800100028 Optical potential parameter E136800100029 See NRDF D1368 DATA,64 for detail. E136800100030 E1368.066:28-NI-64(D,EL)28-NI-64 E136800100031 Optical potential parameter E136800100032 See NRDF D1368 DATA,65 for detail. E136800100033 E1368.067:40-ZR-90(D,EL)40-ZR-90 E136800100034 Optical potential parameter E136800100035 See NRDF D1368 DATA,66 for detail. E136800100036 E1368.068:42-MO-92(D,EL)42-MO-92 E136800100037 Optical potential parameter E136800100038 See NRDF D1368 DATA,67 for detail. E136800100039 E1368.069:42-MO-100(D,EL)42-MO-100 E136800100040 Optical potential parameter E136800100041 See NRDF D1368 DATA,68 for detail. E136800100042 E1368.070:46-PD-104(D,EL)46-PD-104 E136800100043 Optical potential parameter E136800100044 See NRDF D1368 DATA,69 for detail. E136800100045 E1368.071:46-PD-106(D,EL)46-PD-106 E136800100046 Optical potential parameter E136800100047 See NRDF D1368 DATA,70 for detail. E136800100048 E1368.072:46-PD-108(D,EL)46-PD-108 E136800100049 Optical potential parameter E136800100050 See NRDF D1368 DATA,71 for detail. E136800100051 E1368.073:46-PD-110(D,EL)46-PD-110 E136800100052 Optical potential parameter E136800100053 See NRDF D1368 DATA,72 for detail. E136800100054 (COMP) Optical model (Tr-type tensor potential [G.R. E136800100055 Satchler, Nucl. Phys. 21(1960)116]) E136800100056 HISTORY (20060523T) On. Converted from NRDF D1368 E136800100057 (20060731A) Is. Re-digitized E136800100058 (20070317A) On. Data replaced by tabulated data in E136800100059 thesis E136800100060 ENDBIB 58 0 E136800100061 COMMON 1 3 E136800100062 POL-BM E136800100063 NO-DIM E136800100064 0.8 E136800100065 ENDCOMMON 3 0 E136800100066 ENDSUBENT 65 0 E136800199999 SUBENT E1368002 20080131 E051E136800200001 BIB 7 13 E136800200002 REACTION (20-CA-40(D,EL)20-CA-40,,DA,,RTH) E136800200003 EN-SEC ANG is polar angle between beam and deuteron in E136800200004 laboratory system E136800200005 SAMPLE - Target is natural. E136800200006 - Target-thickness is 0.51 mg/cm**2. E136800200007 - Backing is mylar film. E136800200008 - Backing-thickness: 1-micro meter E136800200009 METHOD (EDE) E136800200010 DETECTOR Solid angle of detector is 1.83 msr. E136800200011 (TELES) To detect scattered deuteron E136800200012 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E136800200013 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136800200014 doctor thesis of M.Takei E136800200015 ENDBIB 13 0 E136800200016 COMMON 3 3 E136800200017 EN E-RSL ANG-ERR E136800200018 MEV KEV ADEG E136800200019 22. 90. 1.3 E136800200020 ENDCOMMON 3 0 E136800200021 DATA 3 27 E136800200022 ANG-CM DATA DATA-ERR E136800200023 ADEG NO-DIM NO-DIM E136800200024 41.84 8.330E+00 8.330E-02 E136800200025 47.03 8.110E+00 8.110E-02 E136800200026 52.20 2.190E+01 2.190E-01 E136800200027 57.35 2.080E+01 2.080E-01 E136800200028 62.48 1.030E+01 1.030E-01 E136800200029 67.60 3.060E+00 3.060E-02 E136800200030 72.69 1.140E+00 1.140E-02 E136800200031 77.77 1.750E+00 1.750E-02 E136800200032 82.82 2.320E+00 2.320E-02 E136800200033 87.86 2.350E+00 2.350E-02 E136800200034 92.87 1.980E+00 1.980E-02 E136800200035 97.86 1.470E+00 1.470E-02 E136800200036 102.82 1.120E+00 1.120E-02 E136800200037 107.77 9.500E-01 9.500E-03 E136800200038 112.69 9.390E-01 9.390E-03 E136800200039 117.60 1.010E+00 1.010E-02 E136800200040 122.48 1.020E+00 1.020E-02 E136800200041 127.35 9.530E-01 9.530E-03 E136800200042 132.20 8.550E-01 8.550E-03 E136800200043 137.03 6.960E-01 6.960E-03 E136800200044 141.84 5.520E-01 5.520E-03 E136800200045 146.64 4.450E-01 4.450E-03 E136800200046 151.43 4.270E-01 4.270E-03 E136800200047 156.21 5.370E-01 5.370E-03 E136800200048 160.98 7.100E-01 7.100E-03 E136800200049 165.74 7.650E-01 7.650E-03 E136800200050 170.50 7.460E-01 7.460E-03 E136800200051 ENDDATA 29 0 E136800200052 ENDSUBENT 51 0 E136800299999 SUBENT E1368003 20080131 E051E136800300001 BIB 7 11 E136800300002 REACTION (28-NI-58(D,EL)28-NI-58,,DA,,RTH) E136800300003 EN-SEC ANG is polar angle between beam and deuteron in E136800300004 laboratory system E136800300005 SAMPLE - Target enrichment is 99.89%. E136800300006 - Target-thickness is 0.98 mg/cm**2. E136800300007 METHOD (EDE) E136800300008 DETECTOR Solid angle of detector is 1.83 msr. E136800300009 (TELES) To detect scattered deuteron E136800300010 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E136800300011 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136800300012 doctor thesis of M.Takei E136800300013 ENDBIB 11 0 E136800300014 COMMON 3 3 E136800300015 EN E-RSL ANG-ERR E136800300016 MEV KEV ADEG E136800300017 22. 90. 1.3 E136800300018 ENDCOMMON 3 0 E136800300019 DATA 3 29 E136800300020 ANG-CM DATA DATA-ERR E136800300021 ADEG NO-DIM NO-DIM E136800300022 30.99 1.350E+02 1.910E-01 E136800300023 36.13 6.450E+01 1.330E-01 E136800300024 41.27 2.520E+01 8.300E-02 E136800300025 46.40 2.170E+01 5.460E-02 E136800300026 51.51 1.610E+01 4.720E-02 E136800300027 56.62 6.100E+00 2.050E-02 E136800300028 61.71 1.010E+00 6.870E-03 E136800300029 66.79 2.370E+00 1.050E-02 E136800300030 71.86 3.530E+00 1.080E-02 E136800300031 76.91 2.630E+00 9.370E-03 E136800300032 81.95 9.460E-01 4.370E-03 E136800300033 86.97 1.750E-01 1.880E-03 E136800300034 91.98 2.860E-01 2.410E-03 E136800300035 96.97 5.570E-01 3.380E-03 E136800300036 101.95 5.450E-01 3.350E-03 E136800300037 106.91 3.580E-01 2.720E-03 E136800300038 111.86 1.680E-01 1.870E-03 E136800300039 116.79 8.660E-02 1.610E-03 E136800300040 121.71 8.260E-02 1.570E-03 E136800300041 126.62 1.120E-01 1.830E-03 E136800300042 131.51 1.350E-01 2.010E-03 E136800300043 136.40 1.330E-01 2.000E-03 E136800300044 141.27 1.060E-01 1.270E-03 E136800300045 146.13 6.760E-02 1.020E-03 E136800300046 150.99 4.470E-02 8.280E-04 E136800300047 155.84 4.070E-02 7.910E-04 E136800300048 160.68 6.360E-02 9.890E-04 E136800300049 165.51 9.800E-02 1.230E-03 E136800300050 170.34 1.120E-01 1.320E-03 E136800300051 ENDDATA 31 0 E136800300052 ENDSUBENT 51 0 E136800399999 SUBENT E1368004 20080131 E051E136800400001 BIB 7 11 E136800400002 REACTION (28-NI-60(D,EL)28-NI-60,,DA,,RTH) E136800400003 EN-SEC ANG is polar angle between beam and deuteron in E136800400004 laboratory system E136800400005 SAMPLE - Target enrichment is 99.79%. E136800400006 - Target-thickness is 0.95 mg/cm**2. E136800400007 METHOD (EDE) E136800400008 DETECTOR Solid angle of detector is 1.83 msr. E136800400009 (TELES) To detect scattered deuteron E136800400010 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E136800400011 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136800400012 doctor thesis of M.Takei E136800400013 ENDBIB 11 0 E136800400014 COMMON 3 3 E136800400015 EN E-RSL ANG-ERR E136800400016 MEV KEV ADEG E136800400017 22. 90. 1.3 E136800400018 ENDCOMMON 3 0 E136800400019 DATA 3 28 E136800400020 ANG-CM DATA DATA-ERR E136800400021 ADEG NO-DIM NO-DIM E136800400022 36.10 8.700E+01 5.310E-01 E136800400023 41.23 3.320E+01 2.040E-01 E136800400024 46.35 2.590E+01 1.590E-01 E136800400025 51.46 1.800E+01 1.200E-01 E136800400026 56.56 5.970E+00 4.820E-02 E136800400027 61.65 1.780E+00 1.460E-02 E136800400028 66.73 4.350E+00 3.070E-02 E136800400029 71.79 4.550E+00 2.890E-02 E136800400030 76.85 2.740E+00 1.810E-02 E136800400031 81.88 7.640E-01 6.220E-03 E136800400032 86.90 2.030E-01 2.540E-03 E136800400033 91.91 5.480E-01 5.020E-03 E136800400034 96.90 8.090E-01 6.830E-03 E136800400035 101.88 6.600E-01 5.790E-03 E136800400036 106.85 3.550E-01 3.680E-03 E136800400037 111.80 1.300E-01 2.430E-03 E136800400038 116.73 9.950E-02 1.980E-03 E136800400039 121.65 1.340E-01 2.370E-03 E136800400040 126.56 1.660E-01 2.810E-03 E136800400041 131.46 1.750E-01 2.920E-03 E136800400042 136.35 1.440E-01 1.960E-03 E136800400043 141.23 1.060E-01 1.540E-03 E136800400044 146.10 7.050E-02 1.210E-03 E136800400045 150.96 4.680E-02 9.540E-04 E136800400046 155.81 5.910E-02 1.130E-03 E136800400047 160.65 9.140E-02 1.480E-03 E136800400048 165.49 1.310E-01 1.790E-03 E136800400049 170.33 1.360E-01 1.800E-03 E136800400050 ENDDATA 30 0 E136800400051 ENDSUBENT 50 0 E136800499999 SUBENT E1368005 20080131 E051E136800500001 BIB 7 11 E136800500002 REACTION (28-NI-62(D,EL)28-NI-62,,DA,,RTH) E136800500003 EN-SEC ANG is polar angle between beam and deuteron in E136800500004 laboratory system E136800500005 SAMPLE - Target enrichment is 98.70%. E136800500006 - Target-thickness is 1.12 mg/cm**2. E136800500007 METHOD (EDE) E136800500008 DETECTOR Solid angle of detector is 1.83 msr. E136800500009 (TELES) To detect scattered deuteron E136800500010 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E136800500011 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136800500012 doctor thesis of M.Takei E136800500013 ENDBIB 11 0 E136800500014 COMMON 3 3 E136800500015 EN E-RSL ANG-ERR E136800500016 MEV KEV ADEG E136800500017 22. 90. 1.3 E136800500018 ENDCOMMON 3 0 E136800500019 DATA 3 29 E136800500020 ANG-CM DATA DATA-ERR E136800500021 ADEG NO-DIM NO-DIM E136800500022 30.92 1.510E+02 1.670E-01 E136800500023 36.06 6.860E+01 8.030E-02 E136800500024 41.19 2.560E+01 3.480E-02 E136800500025 46.31 1.930E+01 3.010E-02 E136800500026 51.42 1.260E+01 4.890E-02 E136800500027 56.51 3.600E+00 1.850E-02 E136800500028 61.60 2.030E+00 9.860E-03 E136800500029 66.68 4.160E+00 1.410E-02 E136800500030 71.74 3.980E+00 1.170E-02 E136800500031 76.79 1.940E+00 6.670E-03 E136800500032 81.82 4.220E-01 3.120E-03 E136800500033 86.84 2.790E-01 2.540E-03 E136800500034 91.85 6.750E-01 4.860E-03 E136800500035 96.84 7.670E-01 4.230E-03 E136800500036 101.82 5.330E-01 3.540E-03 E136800500037 106.79 2.490E-01 2.430E-03 E136800500038 111.74 1.100E-01 1.260E-03 E136800500039 116.68 1.060E-01 1.470E-03 E136800500040 121.60 1.410E-01 1.690E-03 E136800500041 126.51 1.550E-01 1.780E-03 E136800500042 131.42 1.330E-01 1.650E-03 E136800500043 136.31 9.730E-02 1.000E-03 E136800500044 141.19 7.280E-02 8.710E-04 E136800500045 146.06 5.320E-02 7.460E-04 E136800500046 150.92 3.890E-02 6.380E-04 E136800500047 155.78 5.140E-02 7.320E-04 E136800500048 160.63 8.030E-02 9.170E-04 E136800500049 165.48 1.080E-01 1.060E-03 E136800500050 170.32 1.050E-01 1.050E-03 E136800500051 ENDDATA 31 0 E136800500052 ENDSUBENT 51 0 E136800599999 SUBENT E1368006 20080131 E051E136800600001 BIB 7 11 E136800600002 REACTION (28-NI-64(D,EL)28-NI-64,,DA,,RTH) E136800600003 EN-SEC ANG is polar angle between beam and deuteron in E136800600004 laboratory system E136800600005 SAMPLE - Target enrichment is 96.48%. E136800600006 - Target-thickness is 0.82 mg/cm**2. E136800600007 METHOD (EDE) E136800600008 DETECTOR Solid angle of detector is 1.83 msr. E136800600009 (TELES) To detect scattered deuteron E136800600010 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E136800600011 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136800600012 doctor thesis of M.Takei E136800600013 ENDBIB 11 0 E136800600014 COMMON 3 3 E136800600015 EN E-RSL ANG-ERR E136800600016 MEV KEV ADEG E136800600017 22. 90. 1.3 E136800600018 ENDCOMMON 3 0 E136800600019 DATA 3 29 E136800600020 ANG-CM DATA DATA-ERR E136800600021 ADEG NO-DIM NO-DIM E136800600022 30.90 1.670E+02 2.070E-01 E136800600023 36.03 7.740E+01 9.980E-02 E136800600024 41.15 2.910E+01 4.330E-02 E136800600025 46.27 1.960E+01 3.560E-02 E136800600026 51.37 1.150E+01 5.480E-02 E136800600027 56.47 3.510E+00 2.140E-02 E136800600028 61.55 3.130E+00 1.430E-02 E136800600029 66.62 5.440E+00 1.890E-02 E136800600030 71.68 3.780E+00 8.420E-03 E136800600031 76.73 1.620E+00 7.140E-03 E136800600032 81.76 3.430E-01 3.300E-03 E136800600033 86.78 5.120E-01 3.120E-03 E136800600034 91.79 9.280E-01 4.210E-03 E136800600035 96.78 9.000E-01 5.370E-03 E136800600036 101.76 5.340E-01 4.150E-03 E136800600037 106.73 2.250E-01 2.090E-03 E136800600038 111.68 1.220E-01 1.550E-03 E136800600039 116.62 1.510E-01 2.050E-03 E136800600040 121.55 2.040E-01 2.390E-03 E136800600041 126.47 1.970E-01 2.350E-03 E136800600042 131.37 1.540E-01 2.090E-03 E136800600043 136.27 1.140E-01 1.270E-03 E136800600044 141.15 8.320E-02 1.090E-03 E136800600045 146.03 6.420E-02 9.580E-04 E136800600046 150.90 5.680E-02 9.000E-04 E136800600047 155.76 6.820E-02 9.860E-04 E136800600048 160.61 1.060E-01 1.230E-03 E136800600049 165.46 1.290E-01 1.360E-03 E136800600050 170.31 1.330E-01 1.390E-03 E136800600051 ENDDATA 31 0 E136800600052 ENDSUBENT 51 0 E136800699999 SUBENT E1368007 20080131 E051E136800700001 BIB 7 11 E136800700002 REACTION (40-ZR-90(D,EL)40-ZR-90,,DA,,RTH) E136800700003 EN-SEC ANG is polar angle between beam and deuteron in E136800700004 laboratory system E136800700005 SAMPLE - Target enrichment is 97.62%. E136800700006 - Target-thickness is 1.00 mg/cm**2. E136800700007 METHOD (EDE) E136800700008 DETECTOR Solid angle of detector is 1.83 msr. E136800700009 (TELES) To detect scattered deuteron E136800700010 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E136800700011 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136800700012 doctor thesis of M.Takei E136800700013 ENDBIB 11 0 E136800700014 COMMON 3 3 E136800700015 EN E-RSL ANG-ERR E136800700016 MEV KEV ADEG E136800700017 22. 90. 1.3 E136800700018 ENDCOMMON 3 0 E136800700019 DATA 3 30 E136800700020 ANG-CM DATA DATA-ERR E136800700021 ADEG NO-DIM NO-DIM E136800700022 35.73 8.540E+01 6.000E-01 E136800700023 40.82 2.420E+01 1.900E-01 E136800700024 45.90 2.500E+01 2.100E-01 E136800700025 50.98 2.470E+01 1.500E-01 E136800700026 56.04 1.360E+01 1.200E-01 E136800700027 61.10 6.340E+00 6.000E-02 E136800700028 63.63 0.000E+00 0.000E+00 E136800700029 66.15 2.940E+00 3.000E-02 E136800700030 71.20 1.940E+00 2.000E-02 E136800700031 73.31 0.000E+00 0.000E+00 E136800700032 76.23 2.310E+00 2.000E-02 E136800700033 81.25 2.530E+00 2.000E-02 E136800700034 86.27 1.750E+00 2.000E-02 E136800700035 91.27 8.550E-01 9.000E-03 E136800700036 96.27 3.020E-01 3.000E-03 E136800700037 101.25 5.370E-01 5.000E-03 E136800700038 106.23 7.240E-01 6.000E-03 E136800700039 111.20 5.860E-01 5.000E-03 E136800700040 116.15 2.800E-01 3.000E-03 E136800700041 121.10 1.340E-01 1.000E-03 E136800700042 126.04 1.160E-01 1.000E-03 E136800700043 130.98 1.840E-01 2.000E-03 E136800700044 135.90 2.020E-01 2.000E-03 E136800700045 140.82 1.640E-01 2.000E-03 E136800700046 145.73 1.190E-01 1.000E-03 E136800700047 150.64 6.160E-02 7.000E-04 E136800700048 155.54 3.550E-02 5.000E-04 E136800700049 160.44 8.230E-02 1.100E-03 E136800700050 165.33 1.320E-01 1.000E-03 E136800700051 170.22 1.630E-01 2.000E-03 E136800700052 ENDDATA 32 0 E136800700053 ENDSUBENT 52 0 E136800799999 SUBENT E1368008 20080131 E051E136800800001 BIB 7 11 E136800800002 REACTION (42-MO-92(D,EL)42-MO-92,,DA,,RTH) E136800800003 EN-SEC ANG is polar angle between beam and deuteron in E136800800004 laboratory system E136800800005 SAMPLE - Target enrichment is 95.13%. E136800800006 - Target-thickness is 1.62 mg/cm**2. E136800800007 METHOD (EDE) E136800800008 DETECTOR Solid angle of detector is 1.83 msr. E136800800009 (TELES) To detect scattered deuteron E136800800010 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E136800800011 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136800800012 doctor thesis of M.Takei E136800800013 ENDBIB 11 0 E136800800014 COMMON 3 3 E136800800015 EN E-RSL ANG-ERR E136800800016 MEV KEV ADEG E136800800017 22. 90. 1.3 E136800800018 ENDCOMMON 3 0 E136800800019 DATA 3 29 E136800800020 ANG-CM DATA DATA-ERR E136800800021 ADEG NO-DIM NO-DIM E136800800022 30.62 3.920E+02 2.570E+00 E136800800023 35.71 1.290E+02 8.420E-01 E136800800024 40.80 3.460E+01 2.330E-01 E136800800025 45.88 3.430E+01 2.310E-01 E136800800026 50.95 2.910E+01 2.020E-01 E136800800027 56.02 1.580E+01 1.200E-01 E136800800028 61.08 7.210E+00 5.670E-02 E136800800029 66.13 3.000E+00 2.790E-02 E136800800030 71.17 2.340E+00 1.850E-02 E136800800031 76.20 2.670E+00 2.130E-02 E136800800032 81.23 2.760E+00 2.180E-02 E136800800033 86.24 1.860E+00 1.330E-02 E136800800034 91.25 7.470E-01 6.140E-03 E136800800035 96.24 2.940E-01 4.310E-03 E136800800036 101.23 4.600E-01 5.820E-03 E136800800037 106.20 6.450E-01 5.600E-03 E136800800038 111.17 5.930E-01 4.960E-03 E136800800039 116.13 2.520E-01 2.960E-03 E136800800040 121.08 1.120E-01 1.760E-03 E136800800041 126.02 1.040E-01 1.730E-03 E136800800042 130.95 1.710E-01 1.920E-03 E136800800043 135.88 2.090E-01 2.400E-03 E136800800044 140.80 1.610E-01 1.960E-03 E136800800045 145.71 1.110E-01 1.460E-03 E136800800046 150.62 6.510E-02 1.120E-03 E136800800047 155.53 4.700E-02 9.350E-04 E136800800048 160.43 6.460E-02 1.160E-03 E136800800049 165.32 1.030E-01 1.480E-03 E136800800050 170.22 1.190E-01 1.560E-03 E136800800051 ENDDATA 31 0 E136800800052 ENDSUBENT 51 0 E136800899999 SUBENT E1368009 20080131 E051E136800900001 BIB 7 11 E136800900002 REACTION (42-MO-100(D,EL)42-MO-100,,DA,,RTH) E136800900003 EN-SEC ANG is polar angle between beam and deuteron in E136800900004 laboratory system E136800900005 SAMPLE - Target enrichment is 97.27%. E136800900006 - Target-thickness is 1.52 mg/cm**2. E136800900007 METHOD (EDE) E136800900008 DETECTOR Solid angle of detector is 1.83 msr. E136800900009 (TELES) To detect scattered deuteron E136800900010 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E136800900011 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136800900012 doctor thesis of M.Takei E136800900013 ENDBIB 11 0 E136800900014 COMMON 3 3 E136800900015 EN E-RSL ANG-ERR E136800900016 MEV KEV ADEG E136800900017 22. 90. 1.3 E136800900018 ENDCOMMON 3 0 E136800900019 DATA 3 29 E136800900020 ANG-CM DATA DATA-ERR E136800900021 ADEG NO-DIM NO-DIM E136800900022 30.57 3.620E+02 2.900E-01 E136800900023 35.66 1.090E+02 1.120E-01 E136800900024 40.74 5.290E+01 7.830E-02 E136800900025 45.81 4.720E+01 5.230E-02 E136800900026 50.88 2.740E+01 7.970E-02 E136800900027 55.94 1.080E+01 3.550E-02 E136800900028 60.99 5.980E+00 2.640E-02 E136800900029 66.04 4.410E+00 1.600E-02 E136800900030 71.08 3.120E+00 1.140E-02 E136800900031 76.11 2.460E+00 1.010E-02 E136800900032 81.13 1.750E+00 8.540E-03 E136800900033 86.14 8.440E-01 5.950E-03 E136800900034 91.15 3.800E-01 4.000E-03 E136800900035 96.14 4.350E-01 4.280E-03 E136800900036 101.13 5.360E-01 4.760E-03 E136800900037 106.11 4.270E-01 4.260E-03 E136800900038 111.08 1.930E-01 2.870E-03 E136800900039 116.04 7.830E-02 1.780E-03 E136800900040 120.99 7.520E-02 1.510E-03 E136800900041 125.94 1.110E-01 2.120E-03 E136800900042 130.88 1.190E-01 2.200E-03 E136800900043 135.81 7.940E-02 1.100E-03 E136800900044 140.74 4.710E-02 8.500E-04 E136800900045 145.66 2.790E-02 5.860E-04 E136800900046 150.57 2.810E-02 5.870E-04 E136800900047 155.48 3.470E-02 7.310E-04 E136800900048 160.39 3.840E-02 7.690E-04 E136800900049 165.30 3.930E-02 6.970E-04 E136800900050 170.20 3.260E-02 6.350E-04 E136800900051 ENDDATA 31 0 E136800900052 ENDSUBENT 51 0 E136800999999 SUBENT E1368010 20080131 E051E136801000001 BIB 7 12 E136801000002 REACTION (46-PD-104(D,EL)46-PD-104,,DA,,RTH) E136801000003 EN-SEC ANG is polar angle between beam and deuteron in E136801000004 laboratory system E136801000005 SAMPLE - Target enrichment is 95.25%. E136801000006 - Target-thickness is 3.25 mg/cm**2. E136801000007 METHOD (EDE) E136801000008 DETECTOR Solid angle of detector is 2 msr. E136801000009 (MAGSP,SWPC) To momentum analyze and detect scattered E136801000010 deuteron E136801000011 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E136801000012 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136801000013 doctor thesis of M.Takei E136801000014 ENDBIB 12 0 E136801000015 COMMON 2 3 E136801000016 EN ANG-ERR E136801000017 MEV ADEG E136801000018 21. 1.5 E136801000019 ENDCOMMON 3 0 E136801000020 DATA 3 34 E136801000021 ANG-CM DATA DATA-ERR E136801000022 ADEG NO-DIM NO-DIM E136801000023 20.38 4.590E+03 1.230E+01 E136801000024 25.47 1.570E+03 3.210E+00 E136801000025 30.55 7.000E+02 1.180E+00 E136801000026 35.63 2.460E+02 6.990E-01 E136801000027 40.71 1.080E+02 3.280E-01 E136801000028 45.78 8.850E+01 2.970E-01 E136801000029 50.84 5.550E+01 7.430E-02 E136801000030 55.90 2.290E+01 4.780E-02 E136801000031 60.95 1.030E+01 2.270E-02 E136801000032 66.00 8.700E+00 2.100E-02 E136801000033 68.52 8.210E+00 2.040E-02 E136801000034 71.04 7.460E+00 1.940E-02 E136801000035 76.06 5.090E+00 1.310E-02 E136801000036 81.09 3.040E+00 1.020E-02 E136801000037 86.10 1.680E+00 7.560E-03 E136801000038 91.10 1.020E+00 5.910E-03 E136801000039 93.60 9.250E-01 4.410E-03 E136801000040 96.10 9.190E-01 4.410E-03 E136801000041 101.09 9.220E-01 4.420E-03 E136801000042 106.06 7.460E-01 3.980E-03 E136801000043 108.55 6.050E-01 3.580E-03 E136801000044 111.04 4.430E-01 3.070E-03 E136801000045 116.00 2.170E-01 1.970E-03 E136801000046 120.95 1.660E-01 1.730E-03 E136801000047 125.90 2.170E-01 2.120E-03 E136801000048 130.84 2.420E-01 2.240E-03 E136801000049 135.78 1.880E-01 1.970E-03 E136801000050 140.71 1.220E-01 1.590E-03 E136801000051 145.63 7.370E-02 1.240E-03 E136801000052 150.55 5.840E-02 1.100E-03 E136801000053 155.47 6.920E-02 1.210E-03 E136801000054 160.38 8.190E-02 2.880E-03 E136801000055 165.29 8.760E-02 3.060E-03 E136801000056 170.19 8.200E-02 2.890E-03 E136801000057 ENDDATA 36 0 E136801000058 ENDSUBENT 57 0 E136801099999 SUBENT E1368011 20080131 E051E136801100001 BIB 7 12 E136801100002 REACTION (46-PD-106(D,EL)46-PD-106,,DA,,RTH) E136801100003 EN-SEC ANG is polar angle between beam and deuteron in E136801100004 laboratory system E136801100005 SAMPLE - Target enrichment is 96.66%. E136801100006 - Target-thickness is 3.42 mg/cm**2. E136801100007 METHOD (EDE) E136801100008 DETECTOR Solid angle of detector is 2 msr. E136801100009 (MAGSP,SWPC) To momentum analyze and detect scattered E136801100010 deuteron E136801100011 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E136801100012 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136801100013 doctor thesis of M.Takei E136801100014 ENDBIB 12 0 E136801100015 COMMON 2 3 E136801100016 EN ANG-ERR E136801100017 MEV ADEG E136801100018 21. 1.5 E136801100019 ENDCOMMON 3 0 E136801100020 DATA 3 31 E136801100021 ANG-CM DATA DATA-ERR E136801100022 ADEG NO-DIM NO-DIM E136801100023 20.37 5.430E+03 1.320E+01 E136801100024 25.46 1.820E+03 5.390E+00 E136801100025 30.54 8.030E+02 1.610E+00 E136801100026 35.62 2.810E+02 9.510E-01 E136801100027 40.69 1.290E+02 4.550E-01 E136801100028 45.76 9.820E+01 1.030E-01 E136801100029 50.83 5.770E+01 7.910E-02 E136801100030 55.89 2.360E+01 4.790E-02 E136801100031 60.94 1.200E+01 2.420E-02 E136801100032 65.98 1.070E+01 2.290E-02 E136801100033 71.02 8.590E+00 2.050E-02 E136801100034 76.04 5.500E+00 1.340E-02 E136801100035 81.06 3.190E+00 1.020E-02 E136801100036 86.08 1.830E+00 7.760E-03 E136801100037 91.08 1.230E+00 6.390E-03 E136801100038 96.08 1.100E+00 5.410E-03 E136801100039 101.06 1.040E+00 4.700E-03 E136801100040 106.04 7.850E-01 4.090E-03 E136801100041 111.02 4.400E-01 3.060E-03 E136801100042 115.98 2.310E-01 2.030E-03 E136801100043 120.94 2.080E-01 1.930E-03 E136801100044 125.89 2.490E-01 2.310E-03 E136801100045 130.83 2.500E-01 2.310E-03 E136801100046 135.76 1.890E-01 2.000E-03 E136801100047 140.69 1.220E-01 1.620E-03 E136801100048 145.62 7.770E-02 1.290E-03 E136801100049 150.54 7.320E-02 1.260E-03 E136801100050 155.46 8.740E-02 1.370E-03 E136801100051 160.37 9.770E-02 1.120E-03 E136801100052 165.28 9.270E-02 1.070E-03 E136801100053 170.19 7.560E-02 9.340E-04 E136801100054 ENDDATA 33 0 E136801100055 ENDSUBENT 54 0 E136801199999 SUBENT E1368012 20080131 E051E136801200001 BIB 7 12 E136801200002 REACTION (46-PD-108(D,EL)46-PD-108,,DA,,RTH) E136801200003 EN-SEC ANG is polar angle between beam and deuteron in E136801200004 laboratory system E136801200005 SAMPLE - Target enrichment is 98.11%. E136801200006 - Target-thickness is 3.26 mg/cm**2. E136801200007 METHOD (EDE) E136801200008 DETECTOR Solid angle of detector is 2 msr. E136801200009 (MAGSP,SWPC) To momentum analyze and detect scattered E136801200010 deuteron E136801200011 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E136801200012 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136801200013 doctor thesis of M.Takei E136801200014 ENDBIB 12 0 E136801200015 COMMON 2 3 E136801200016 EN ANG-ERR E136801200017 MEV ADEG E136801200018 21. 1.5 E136801200019 ENDCOMMON 3 0 E136801200020 DATA 3 30 E136801200021 ANG-CM DATA DATA-ERR E136801200022 ADEG NO-DIM NO-DIM E136801200023 30.53 6.910E+02 4.070E-01 E136801200024 35.61 2.410E+02 1.950E-01 E136801200025 40.68 1.160E+02 1.300E-01 E136801200026 45.75 9.060E+01 1.140E-01 E136801200027 50.81 5.170E+01 5.010E-02 E136801200028 55.87 2.090E+01 5.490E-02 E136801200029 60.92 1.160E+01 2.910E-02 E136801200030 65.96 1.040E+01 2.770E-02 E136801200031 71.00 7.690E+00 2.380E-02 E136801200032 76.02 4.670E+00 1.510E-02 E136801200033 81.04 2.690E+00 1.140E-02 E136801200034 86.06 1.670E+00 9.070E-03 E136801200035 91.06 1.190E+00 7.710E-03 E136801200036 96.06 1.030E+00 7.690E-03 E136801200037 101.04 8.910E-01 6.150E-03 E136801200038 106.02 6.320E-01 4.210E-03 E136801200039 111.00 3.590E-01 3.170E-03 E136801200040 115.96 2.190E-01 2.180E-03 E136801200041 120.92 2.090E-01 2.150E-03 E136801200042 123.39 0.000E+00 0.000E+00 E136801200043 125.87 2.080E-01 1.920E-03 E136801200044 130.81 1.920E-01 1.670E-03 E136801200045 135.75 1.380E-01 1.410E-03 E136801200046 140.68 8.760E-02 1.010E-03 E136801200047 145.61 6.440E-02 8.820E-04 E136801200048 150.53 6.090E-02 8.640E-04 E136801200049 155.45 6.850E-02 9.070E-04 E136801200050 160.36 7.140E-02 6.620E-04 E136801200051 165.27 6.500E-02 5.230E-04 E136801200052 170.18 5.040E-02 4.620E-04 E136801200053 ENDDATA 32 0 E136801200054 ENDSUBENT 53 0 E136801299999 SUBENT E1368013 20080131 E051E136801300001 BIB 7 12 E136801300002 REACTION (46-PD-110(D,EL)46-PD-110,,DA,,RTH) E136801300003 EN-SEC ANG is polar angle between beam and deuteron in E136801300004 laboratory system E136801300005 SAMPLE - Target enrichment is 97.73%. E136801300006 - Target-thickness is 2.26 mg/cm**2. E136801300007 METHOD (EDE) E136801300008 DETECTOR Solid angle of detector is 2 msr. E136801300009 (MAGSP,SWPC) To momentum analyze and detect scattered E136801300010 deuteron E136801300011 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E136801300012 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136801300013 doctor thesis of M.Takei E136801300014 ENDBIB 12 0 E136801300015 COMMON 2 3 E136801300016 EN ANG-ERR E136801300017 MEV ADEG E136801300018 21. 1.5 E136801300019 ENDCOMMON 3 0 E136801300020 DATA 3 25 E136801300021 ANG-CM DATA DATA-ERR E136801300022 ADEG NO-DIM NO-DIM E136801300023 50.80 4.100E+01 1.230E+00 E136801300024 55.85 1.620E+01 4.970E-01 E136801300025 60.90 1.040E+01 3.180E-01 E136801300026 65.94 9.020E+00 2.770E-01 E136801300027 70.98 6.000E+00 1.840E-01 E136801300028 76.01 3.450E+00 1.080E-01 E136801300029 81.03 2.090E+00 6.650E-02 E136801300030 86.04 1.400E+00 4.490E-02 E136801300031 91.04 9.390E-01 3.080E-02 E136801300032 96.04 7.930E-01 2.640E-02 E136801300033 101.03 6.590E-01 2.210E-02 E136801300034 106.01 4.550E-01 1.590E-02 E136801300035 110.98 2.540E-01 9.080E-03 E136801300036 115.94 1.650E-01 5.780E-03 E136801300037 120.90 1.650E-01 5.890E-03 E136801300038 125.85 1.760E-01 6.240E-03 E136801300039 130.80 1.530E-01 5.580E-03 E136801300040 135.74 1.000E-01 3.720E-03 E136801300041 140.67 6.370E-02 2.280E-03 E136801300042 145.60 5.170E-02 1.920E-03 E136801300043 150.52 5.470E-02 2.020E-03 E136801300044 155.44 6.210E-02 2.250E-03 E136801300045 160.36 5.970E-02 2.200E-03 E136801300046 165.27 5.220E-02 1.950E-03 E136801300047 170.18 3.690E-02 1.470E-03 E136801300048 ENDDATA 27 0 E136801300049 ENDSUBENT 48 0 E136801399999 SUBENT E1368014 20080131 E051E136801400001 BIB 7 14 E136801400002 REACTION (20-CA-40(D,EL)20-CA-40,,POL/DA,,VAP) E136801400003 EN-SEC ANG is polar angle between beam and deuteron in E136801400004 laboratory system E136801400005 SAMPLE - Target is natural. E136801400006 - Target-thickness is 0.51 mg/cm**2. E136801400007 - Backing is mylar film. E136801400008 - Backing-thickness: 1-micro meter E136801400009 METHOD (EDE) E136801400010 DETECTOR Solid angle of detector is 1.83 msr. E136801400011 (TELES) To detect scattered deuteron E136801400012 ERR-ANALYS (ERR-T) Total uncertainty E136801400013 (ERR-1) Uncertainty due to measured beam polarizations E136801400014 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136801400015 doctor thesis of M.Takei E136801400016 ENDBIB 14 0 E136801400017 COMMON 4 3 E136801400018 EN E-RSL ANG-ERR ERR-1 E136801400019 MEV KEV ADEG PER-CENT E136801400020 22. 90. 1.3 2. E136801400021 ENDCOMMON 3 0 E136801400022 DATA 3 27 E136801400023 ANG-CM DATA ERR-T E136801400024 ADEG NO-DIM NO-DIM E136801400025 41.84 -0.2317 0.0004 E136801400026 47.03 0.3420 0.0005 E136801400027 52.20 0.0451 0.0013 E136801400028 57.35 -0.0877 0.0016 E136801400029 62.48 -0.2538 0.0037 E136801400030 67.60 -0.5610 0.0082 E136801400031 72.69 -0.1842 0.0046 E136801400032 77.77 0.4788 0.0072 E136801400033 82.82 0.3794 0.0116 E136801400034 87.86 0.1792 0.0031 E136801400035 92.87 -0.1616 0.0030 E136801400036 97.86 -0.5018 0.0074 E136801400037 102.82 -0.6020 0.0089 E136801400038 107.77 -0.3363 0.0057 E136801400039 112.69 -0.0101 0.0044 E136801400040 117.60 0.0285 0.0042 E136801400041 122.48 -0.1346 0.0040 E136801400042 127.35 -0.3241 0.0039 E136801400043 132.20 -0.4303 0.0039 E136801400044 137.03 -0.4449 0.0119 E136801400045 141.84 -0.4756 0.0132 E136801400046 146.64 -0.4675 0.0133 E136801400047 151.43 -0.3221 0.0134 E136801400048 156.21 0.0167 0.0041 E136801400049 160.98 0.1754 0.0060 E136801400050 165.74 0.2275 0.0071 E136801400051 170.50 0.1858 0.0099 E136801400052 ENDDATA 29 0 E136801400053 ENDSUBENT 52 0 E136801499999 SUBENT E1368015 20080131 E051E136801500001 BIB 7 12 E136801500002 REACTION (28-NI-58(D,EL)28-NI-58,,POL/DA,,VAP) E136801500003 EN-SEC ANG is polar angle between beam and deuteron in E136801500004 laboratory system E136801500005 SAMPLE - Target enrichment is 99.89%. E136801500006 - Target-thickness is 0.98 mg/cm**2. E136801500007 METHOD (EDE) E136801500008 DETECTOR Solid angle of detector is 1.83 msr. E136801500009 (TELES) To detect scattered deuteron E136801500010 ERR-ANALYS (ERR-T) Total uncertainty E136801500011 (ERR-1) Uncertainty due to measured beam polarizations E136801500012 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136801500013 doctor thesis of M.Takei E136801500014 ENDBIB 12 0 E136801500015 COMMON 4 3 E136801500016 EN E-RSL ANG-ERR ERR-1 E136801500017 MEV KEV ADEG PER-CENT E136801500018 22. 90. 1.3 2. E136801500019 ENDCOMMON 3 0 E136801500020 DATA 3 29 E136801500021 ANG-CM DATA ERR-T E136801500022 ADEG NO-DIM NO-DIM E136801500023 30.99 -0.0354 0.0091 E136801500024 36.13 0.0362 0.0098 E136801500025 41.27 0.0954 0.0109 E136801500026 46.40 -0.0740 0.0083 E136801500027 51.51 -0.2079 0.0077 E136801500028 56.62 -0.2932 0.0072 E136801500029 61.71 0.2341 0.0151 E136801500030 66.79 0.2517 0.0128 E136801500031 71.86 -0.0105 0.0100 E136801500032 76.91 -0.1880 0.0105 E136801500033 81.95 -0.4555 0.0089 E136801500034 86.97 -0.5485 0.0167 E136801500035 91.98 0.5238 0.0217 E136801500036 96.97 0.3544 0.0166 E136801500037 101.95 0.1313 0.0134 E136801500038 106.91 -0.1513 0.0114 E136801500039 111.86 -0.5228 0.0138 E136801500040 116.79 -0.5803 0.0240 E136801500041 121.71 0.1792 0.0242 E136801500042 126.62 0.4076 0.0218 E136801500043 131.51 0.2366 0.0176 E136801500044 136.40 -0.0187 0.0155 E136801500045 141.27 -0.3087 0.0139 E136801500046 146.13 -0.6034 0.0198 E136801500047 150.99 -0.7705 0.0263 E136801500048 155.84 -0.1888 0.0222 E136801500049 160.68 0.4071 0.0237 E136801500050 165.51 0.5851 0.0254 E136801500051 170.34 0.5468 0.0234 E136801500052 ENDDATA 31 0 E136801500053 ENDSUBENT 52 0 E136801599999 SUBENT E1368016 20080131 E051E136801600001 BIB 7 12 E136801600002 REACTION (28-NI-60(D,EL)28-NI-60,,POL/DA,,VAP) E136801600003 EN-SEC ANG is polar angle between beam and deuteron in E136801600004 laboratory system E136801600005 SAMPLE - Target enrichment is 99.79%. E136801600006 - Target-thickness is 0.95 mg/cm**2. E136801600007 METHOD (EDE) E136801600008 DETECTOR Solid angle of detector is 1.83 msr. E136801600009 (TELES) To detect scattered deuteron E136801600010 ERR-ANALYS (ERR-T) Total uncertainty E136801600011 (ERR-1) Uncertainty due to measured beam polarizations E136801600012 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136801600013 doctor thesis of M.Takei E136801600014 ENDBIB 12 0 E136801600015 COMMON 4 3 E136801600016 EN E-RSL ANG-ERR ERR-1 E136801600017 MEV KEV ADEG PER-CENT E136801600018 22. 90. 1.3 2. E136801600019 ENDCOMMON 3 0 E136801600020 DATA 3 28 E136801600021 ANG-CM DATA ERR-T E136801600022 ADEG NO-DIM NO-DIM E136801600023 36.10 0.0525 0.0027 E136801600024 41.23 0.0502 0.0030 E136801600025 46.35 -0.1221 0.0044 E136801600026 51.46 -0.2052 0.0065 E136801600027 56.56 -0.2267 0.0087 E136801600028 61.65 0.4081 0.0157 E136801600029 66.73 0.0941 0.0078 E136801600030 71.79 -0.0966 0.0079 E136801600031 76.85 -0.2657 0.0127 E136801600032 81.88 -0.5855 0.0201 E136801600033 86.90 0.1661 0.0176 E136801600034 91.91 0.4012 0.0154 E136801600035 96.90 0.1904 0.0100 E136801600036 101.88 -0.0592 0.0089 E136801600037 106.85 -0.3675 0.0175 E136801600038 111.80 -0.7320 0.0280 E136801600039 116.73 -0.0997 0.0192 E136801600040 121.65 0.3882 0.0234 E136801600041 126.56 0.3394 0.0203 E136801600042 131.46 0.0104 0.0128 E136801600043 136.35 -0.3328 0.0182 E136801600044 141.23 -0.5069 0.0289 E136801600045 146.10 -0.6865 0.0326 E136801600046 150.96 -0.5317 0.0337 E136801600047 155.81 0.0115 0.0257 E136801600048 160.65 0.3194 0.0209 E136801600049 165.49 0.3843 0.0196 E136801600050 170.33 0.3795 0.0201 E136801600051 ENDDATA 30 0 E136801600052 ENDSUBENT 51 0 E136801699999 SUBENT E1368017 20080131 E051E136801700001 BIB 7 12 E136801700002 REACTION (28-NI-62(D,EL)28-NI-62,,POL/DA,,VAP) E136801700003 EN-SEC ANG is polar angle between beam and deuteron in E136801700004 laboratory system E136801700005 SAMPLE - Target enrichment is 98.70%. E136801700006 - Target-thickness is 1.12 mg/cm**2. E136801700007 METHOD (EDE) E136801700008 DETECTOR Solid angle of detector is 1.83 msr. E136801700009 (TELES) To detect scattered deuteron E136801700010 ERR-ANALYS (ERR-T) Total uncertainty E136801700011 (ERR-1) Uncertainty due to measured beam polarizations E136801700012 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136801700013 doctor thesis of M.Takei E136801700014 ENDBIB 12 0 E136801700015 COMMON 4 3 E136801700016 EN E-RSL ANG-ERR ERR-1 E136801700017 MEV KEV ADEG PER-CENT E136801700018 22. 90. 1.3 2. E136801700019 ENDCOMMON 3 0 E136801700020 DATA 3 29 E136801700021 ANG-CM DATA ERR-T E136801700022 ADEG NO-DIM NO-DIM E136801700023 30.92 -0.0025 0.0105 E136801700024 36.06 0.0288 0.0109 E136801700025 41.19 0.0135 0.0106 E136801700026 46.31 -0.1471 0.0088 E136801700027 51.42 -0.2127 0.0093 E136801700028 56.51 -0.0695 0.0120 E136801700029 61.60 0.3861 0.0165 E136801700030 66.68 0.0140 0.0111 E136801700031 71.74 -0.1806 0.0087 E136801700032 76.79 -0.4005 0.0067 E136801700033 81.82 -0.6910 0.0100 E136801700034 86.84 0.4521 0.0195 E136801700035 91.85 0.3064 0.0153 E136801700036 96.84 0.0528 0.0118 E136801700037 101.82 -0.2244 0.0100 E136801700038 106.79 -0.5781 0.0127 E136801700039 111.74 -0.5929 0.0159 E136801700040 116.68 0.2537 0.0205 E136801700041 121.60 0.3897 0.0190 E136801700042 126.51 0.1630 0.0153 E136801700043 131.42 -0.1971 0.0132 E136801700044 136.31 -0.5276 0.0121 E136801700045 141.19 -0.6131 0.0154 E136801700046 146.06 -0.4708 0.0183 E136801700047 150.92 -0.1749 0.0177 E136801700048 155.78 0.0686 0.0129 E136801700049 160.63 0.1940 0.0146 E136801700050 165.48 0.1608 0.0159 E136801700051 170.32 0.1055 0.0165 E136801700052 ENDDATA 31 0 E136801700053 ENDSUBENT 52 0 E136801799999 SUBENT E1368018 20080131 E051E136801800001 BIB 7 12 E136801800002 REACTION (28-NI-64(D,EL)28-NI-64,,POL/DA,,VAP) E136801800003 EN-SEC ANG is polar angle between beam and deuteron in E136801800004 laboratory system E136801800005 SAMPLE - Target enrichment is 96.48%. E136801800006 - Target-thickness is 0.82 mg/cm**2. E136801800007 METHOD (EDE) E136801800008 DETECTOR Solid angle of detector is 1.83 msr. E136801800009 (TELES) To detect scattered deuteron E136801800010 ERR-ANALYS (ERR-T) Total uncertainty E136801800011 (ERR-1) Uncertainty due to measured beam polarizations E136801800012 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136801800013 doctor thesis of M.Takei E136801800014 ENDBIB 12 0 E136801800015 COMMON 4 3 E136801800016 EN E-RSL ANG-ERR ERR-1 E136801800017 MEV KEV ADEG PER-CENT E136801800018 22. 90. 1.3 2. E136801800019 ENDCOMMON 3 0 E136801800020 DATA 3 29 E136801800021 ANG-CM DATA ERR-T E136801800022 ADEG NO-DIM NO-DIM E136801800023 30.90 0.0113 0.0120 E136801800024 36.03 0.0354 0.0122 E136801800025 41.15 -0.0215 0.0115 E136801800026 46.27 -0.1784 0.0096 E136801800027 51.37 -0.2055 0.0113 E136801800028 56.47 0.0512 0.0141 E136801800029 61.55 0.2985 0.0149 E136801800030 66.62 -0.0448 0.0110 E136801800031 71.68 -0.2532 0.0076 E136801800032 76.73 -0.4973 0.0079 E136801800033 81.76 -0.4598 0.0148 E136801800034 86.78 0.4439 0.0173 E136801800035 91.79 0.1694 0.0132 E136801800036 96.78 -0.0959 0.0106 E136801800037 101.76 -0.4020 0.0104 E136801800038 106.73 -0.6931 0.0128 E136801800039 111.68 -0.2021 0.0179 E136801800040 116.62 0.3829 0.0203 E136801800041 121.55 0.3206 0.0173 E136801800042 126.47 -0.0046 0.0147 E136801800043 131.37 -0.4050 0.0158 E136801800044 136.27 -0.6882 0.0146 E136801800045 141.15 -0.4434 0.0173 E136801800046 146.03 -0.0648 0.0201 E136801800047 150.90 0.1066 0.0182 E136801800048 155.76 -0.0080 0.0122 E136801800049 160.61 -0.0252 0.0124 E136801800050 165.46 -0.0594 0.0141 E136801800051 170.31 -0.0854 0.0157 E136801800052 ENDDATA 31 0 E136801800053 ENDSUBENT 52 0 E136801899999 SUBENT E1368019 20080131 E051E136801900001 BIB 7 12 E136801900002 REACTION (40-ZR-90(D,EL)40-ZR-90,,POL/DA,,VAP) E136801900003 EN-SEC ANG is polar angle between beam and deuteron in E136801900004 laboratory system E136801900005 SAMPLE - Target enrichment is 97.62%. E136801900006 - Target-thickness is 1.00 mg/cm**2. E136801900007 METHOD (EDE) E136801900008 DETECTOR Solid angle of detector is 1.83 msr. E136801900009 (TELES) To detect scattered deuteron E136801900010 ERR-ANALYS (ERR-T) Total uncertainty E136801900011 (ERR-1) Uncertainty due to measured beam polarizations E136801900012 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136801900013 doctor thesis of M.Takei E136801900014 ENDBIB 12 0 E136801900015 COMMON 4 3 E136801900016 EN E-RSL ANG-ERR ERR-1 E136801900017 MEV KEV ADEG PER-CENT E136801900018 22. 90. 1.3 2. E136801900019 ENDCOMMON 3 0 E136801900020 DATA 3 29 E136801900021 ANG-CM DATA ERR-T E136801900022 ADEG NO-DIM NO-DIM E136801900023 35.73 -0.0601 0.0018 E136801900024 40.82 -0.0089 0.0019 E136801900025 45.90 0.0815 0.0027 E136801900026 50.98 0.0692 0.0025 E136801900027 56.04 -0.0547 0.0029 E136801900028 61.10 -0.2798 0.0083 E136801900029 63.63 -0.3658 0.0141 E136801900030 66.15 -0.2387 0.0086 E136801900031 71.20 0.3601 0.0113 E136801900032 73.31 0.4429 0.0154 E136801900033 76.23 0.2174 0.0078 E136801900034 81.25 -0.1444 0.0064 E136801900035 86.27 -0.4438 0.0144 E136801900036 91.27 -0.6056 0.0189 E136801900037 96.27 0.1148 0.0104 E136801900038 101.25 0.2707 0.0105 E136801900039 106.23 -0.0489 0.0059 E136801900040 111.20 -0.3935 0.0128 E136801900041 116.15 -0.6997 0.0233 E136801900042 121.10 -0.5485 0.0254 E136801900043 126.04 0.3353 0.0170 E136801900044 130.98 0.2373 0.0125 E136801900045 135.90 -0.1455 0.0109 E136801900046 140.82 -0.4816 0.0181 E136801900047 145.73 -0.7052 0.0266 E136801900048 150.64 -0.6357 0.0271 E136801900049 160.44 0.2689 0.0128 E136801900050 165.33 0.2804 0.0118 E136801900051 170.22 0.2317 0.0114 E136801900052 ENDDATA 31 0 E136801900053 ENDSUBENT 52 0 E136801999999 SUBENT E1368020 20080131 E051E136802000001 BIB 7 12 E136802000002 REACTION (42-MO-92(D,EL)42-MO-92,,POL/DA,,VAP) E136802000003 EN-SEC ANG is polar angle between beam and deuteron in E136802000004 laboratory system E136802000005 SAMPLE - Target enrichment is 95.13%. E136802000006 - Target-thickness is 1.62 mg/cm**2. E136802000007 METHOD (EDE) E136802000008 DETECTOR Solid angle of detector is 1.83 msr. E136802000009 (TELES) To detect scattered deuteron E136802000010 ERR-ANALYS (ERR-T) Total uncertainty E136802000011 (ERR-1) Uncertainty due to measured beam polarizations E136802000012 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136802000013 doctor thesis of M.Takei E136802000014 ENDBIB 12 0 E136802000015 COMMON 4 3 E136802000016 EN E-RSL ANG-ERR ERR-1 E136802000017 MEV KEV ADEG PER-CENT E136802000018 22. 90. 1.3 2. E136802000019 ENDCOMMON 3 0 E136802000020 DATA 3 28 E136802000021 ANG-CM DATA ERR-T E136802000022 ADEG NO-DIM NO-DIM E136802000023 35.71 -0.0731 0.0026 E136802000024 40.80 -0.0237 0.0025 E136802000025 45.88 0.0908 0.0033 E136802000026 50.95 0.0591 0.0029 E136802000027 56.02 -0.0729 0.0052 E136802000028 61.08 -0.2865 0.0094 E136802000029 66.13 -0.1267 0.0086 E136802000030 71.17 0.3406 0.0174 E136802000031 76.20 0.2183 0.0137 E136802000032 81.23 -0.1480 0.0097 E136802000033 86.24 -0.4454 0.0076 E136802000034 91.25 -0.5245 0.0182 E136802000035 96.24 0.2708 0.0193 E136802000036 101.23 0.3070 0.0160 E136802000037 106.20 -0.0956 0.0111 E136802000038 111.17 -0.4380 0.0081 E136802000039 116.13 -0.6739 0.0115 E136802000040 121.08 -0.4009 0.0152 E136802000041 126.02 0.4057 0.0192 E136802000042 130.95 0.2007 0.0148 E136802000043 135.88 -0.2017 0.0100 E136802000044 140.80 -0.5636 0.0110 E136802000045 145.71 -0.7405 0.0129 E136802000046 150.62 -0.5669 0.0165 E136802000047 155.53 0.0056 0.0162 E136802000048 160.43 0.2427 0.0156 E136802000049 165.32 0.2205 0.0160 E136802000050 170.22 0.1622 0.0152 E136802000051 ENDDATA 30 0 E136802000052 ENDSUBENT 51 0 E136802099999 SUBENT E1368021 20080131 E051E136802100001 BIB 7 12 E136802100002 REACTION (42-MO-100(D,EL)42-MO-100,,POL/DA,,VAP) E136802100003 EN-SEC ANG is polar angle between beam and deuteron in E136802100004 laboratory system E136802100005 SAMPLE - Target enrichment is 97.27%. E136802100006 - Target-thickness is 1.52 mg/cm**2. E136802100007 METHOD (EDE) E136802100008 DETECTOR Solid angle of detector is 1.83 msr. E136802100009 (TELES) To detect scattered deuteron E136802100010 ERR-ANALYS (ERR-T) Total uncertainty E136802100011 (ERR-1) Uncertainty due to measured beam polarizations E136802100012 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136802100013 doctor thesis of M.Takei E136802100014 ENDBIB 12 0 E136802100015 COMMON 4 3 E136802100016 EN E-RSL ANG-ERR ERR-1 E136802100017 MEV KEV ADEG PER-CENT E136802100018 22. 90. 1.3 2. E136802100019 ENDCOMMON 3 0 E136802100020 DATA 3 29 E136802100021 ANG-CM DATA ERR-T E136802100022 ADEG NO-DIM NO-DIM E136802100023 30.57 -0.0374 0.0133 E136802100024 35.66 -0.0265 0.0134 E136802100025 40.74 0.0208 0.0132 E136802100026 45.81 0.0083 0.0139 E136802100027 50.88 -0.0428 0.0135 E136802100028 55.94 -0.1022 0.0122 E136802100029 60.99 -0.0909 0.0129 E136802100030 66.04 0.0956 0.0157 E136802100031 71.08 0.1254 0.0140 E136802100032 76.11 -0.0898 0.0125 E136802100033 81.13 -0.2768 0.0115 E136802100034 86.14 -0.2407 0.0140 E136802100035 91.15 0.2235 0.0205 E136802100036 96.14 0.2305 0.0187 E136802100037 101.13 -0.1297 0.0145 E136802100038 106.11 -0.3525 0.0144 E136802100039 111.08 -0.4182 0.0203 E136802100040 116.04 -0.0201 0.0295 E136802100041 120.99 -0.3249 0.0260 E136802100042 125.94 0.0237 0.0234 E136802100043 130.88 -0.2356 0.0230 E136802100044 135.81 -0.4144 0.0179 E136802100045 140.74 -0.3934 0.0223 E136802100046 145.66 0.0900 0.0271 E136802100047 150.57 0.3372 0.0271 E136802100048 155.48 0.1083 0.0241 E136802100049 160.39 -0.2331 0.0216 E136802100050 165.30 -0.4384 0.0216 E136802100051 170.20 -0.4871 0.0236 E136802100052 ENDDATA 31 0 E136802100053 ENDSUBENT 52 0 E136802199999 SUBENT E1368022 20080131 E051E136802200001 BIB 7 13 E136802200002 REACTION (46-PD-104(D,EL)46-PD-104,,POL/DA,,VAP) E136802200003 EN-SEC ANG is polar angle between beam and deuteron in E136802200004 laboratory system E136802200005 SAMPLE - Target enrichment is 95.25%. E136802200006 - Target-thickness is 3.25 mg/cm**2. E136802200007 METHOD (EDE) E136802200008 DETECTOR Solid angle of detector is 2 msr. E136802200009 (MAGSP,SWPC) To momentum analyze and detect scattered E136802200010 deuteron E136802200011 ERR-ANALYS (ERR-T) Total uncertainty E136802200012 (ERR-1) Uncertainty due to measured beam polarizations E136802200013 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136802200014 doctor thesis of M.Takei E136802200015 ENDBIB 13 0 E136802200016 COMMON 3 3 E136802200017 EN ANG-ERR ERR-1 E136802200018 MEV ADEG PER-CENT E136802200019 21. 1.5 2. E136802200020 ENDCOMMON 3 0 E136802200021 DATA 3 34 E136802200022 ANG-CM DATA ERR-T E136802200023 ADEG NO-DIM NO-DIM E136802200024 20.38 -0.0104 0.0024 E136802200025 25.47 -0.0104 0.0019 E136802200026 30.55 -0.0295 0.0016 E136802200027 35.63 -0.0177 0.0025 E136802200028 40.71 0.0268 0.0027 E136802200029 45.78 0.0034 0.0027 E136802200030 50.84 -0.0449 0.0016 E136802200031 55.90 -0.1010 0.0031 E136802200032 60.95 -0.0446 0.0022 E136802200033 66.00 0.0847 0.0030 E136802200034 68.52 0.0941 0.0031 E136802200035 71.04 0.0752 0.0029 E136802200036 76.06 -0.0647 0.0027 E136802200037 81.09 -0.2235 0.0063 E136802200038 86.10 -0.1799 0.0060 E136802200039 91.10 0.1572 0.0064 E136802200040 93.60 0.2592 0.0074 E136802200041 96.10 0.2193 0.0066 E136802200042 101.09 -0.0584 0.0042 E136802200043 106.06 -0.2753 0.0081 E136802200044 108.55 -0.3273 0.0092 E136802200045 111.04 -0.3328 0.0102 E136802200046 116.00 -0.0366 0.0079 E136802200047 120.95 0.3227 0.0111 E136802200048 125.90 0.0857 0.0084 E136802200049 130.84 -0.1559 0.0091 E136802200050 135.78 -0.3072 0.0125 E136802200051 140.71 -0.2899 0.0144 E136802200052 145.63 -0.0336 0.0154 E136802200053 150.55 0.2869 0.0141 E136802200054 155.47 0.1533 0.0149 E136802200055 160.38 -0.1144 0.0113 E136802200056 165.29 -0.3000 0.0127 E136802200057 170.19 -0.3416 0.0135 E136802200058 ENDDATA 36 0 E136802200059 ENDSUBENT 58 0 E136802299999 SUBENT E1368023 20080131 E051E136802300001 BIB 7 13 E136802300002 REACTION (46-PD-106(D,EL)46-PD-106,,POL/DA,,VAP) E136802300003 EN-SEC ANG is polar angle between beam and deuteron in E136802300004 laboratory system E136802300005 SAMPLE - Target enrichment is 96.66%. E136802300006 - Target-thickness is 3.42 mg/cm**2. E136802300007 METHOD (EDE) E136802300008 DETECTOR Solid angle of detector is 2 msr. E136802300009 (MAGSP,SWPC) To momentum analyze and detect scattered E136802300010 deuteron E136802300011 ERR-ANALYS (ERR-T) Total uncertainty E136802300012 (ERR-1) Uncertainty due to measured beam polarizations E136802300013 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136802300014 doctor thesis of M.Takei E136802300015 ENDBIB 13 0 E136802300016 COMMON 3 3 E136802300017 EN ANG-ERR ERR-1 E136802300018 MEV ADEG PER-CENT E136802300019 21. 1.5 2. E136802300020 ENDCOMMON 3 0 E136802300021 DATA 3 28 E136802300022 ANG-CM DATA ERR-T E136802300023 ADEG NO-DIM NO-DIM E136802300024 20.37 0.0027 0.0021 E136802300025 25.46 -0.0125 0.0025 E136802300026 30.54 -0.0315 0.0018 E136802300027 35.62 -0.0159 0.0027 E136802300028 40.69 0.0159 0.0029 E136802300029 45.76 -0.0098 0.0009 E136802300030 50.83 -0.0516 0.0017 E136802300031 55.89 -0.0886 0.0027 E136802300032 60.94 -0.0078 0.0017 E136802300033 65.98 0.0730 0.0025 E136802300034 71.02 0.0365 0.0022 E136802300035 76.04 -0.0963 0.0031 E136802300036 81.06 -0.2122 0.0059 E136802300037 86.08 -0.0956 0.0044 E136802300038 91.08 0.1838 0.0063 E136802300039 96.08 0.1310 0.0052 E136802300040 101.06 -0.1228 0.0048 E136802300041 106.04 -0.2802 0.0081 E136802300042 111.02 -0.2440 0.0086 E136802300043 115.98 0.1248 0.0081 E136802300044 120.94 0.2567 0.0098 E136802300045 125.89 -0.0292 0.0081 E136802300046 130.83 -0.2469 0.0104 E136802300047 135.76 -0.3126 0.0125 E136802300048 140.69 -0.1822 0.0131 E136802300049 145.62 0.1347 0.0150 E136802300050 150.54 0.2529 0.0153 E136802300051 155.46 0.0790 0.0135 E136802300052 ENDDATA 30 0 E136802300053 ENDSUBENT 52 0 E136802399999 SUBENT E1368024 20080131 E051E136802400001 BIB 7 13 E136802400002 REACTION (46-PD-108(D,EL)46-PD-108,,POL/DA,,VAP) E136802400003 EN-SEC ANG is polar angle between beam and deuteron in E136802400004 laboratory system E136802400005 SAMPLE - Target enrichment is 98.11%. E136802400006 - Target-thickness is 3.26 mg/cm**2. E136802400007 METHOD (EDE) E136802400008 DETECTOR Solid angle of detector is 2 msr. E136802400009 (MAGSP,SWPC) To momentum analyze and detect scattered E136802400010 deuteron E136802400011 ERR-ANALYS (ERR-T) Total uncertainty E136802400012 (ERR-1) Uncertainty due to measured beam polarizations E136802400013 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136802400014 doctor thesis of M.Takei E136802400015 ENDBIB 13 0 E136802400016 COMMON 3 3 E136802400017 EN ANG-ERR ERR-1 E136802400018 MEV ADEG PER-CENT E136802400019 21. 1.5 2. E136802400020 ENDCOMMON 3 0 E136802400021 DATA 3 26 E136802400022 ANG-CM DATA ERR-T E136802400023 ADEG NO-DIM NO-DIM E136802400024 30.53 -0.0320 0.0009 E136802400025 35.61 -0.0102 0.0006 E136802400026 40.68 0.0106 0.0009 E136802400027 45.75 -0.0177 0.0011 E136802400028 50.81 -0.0495 0.0015 E136802400029 55.87 -0.0711 0.0027 E136802400030 60.92 0.0040 0.0020 E136802400031 65.96 0.0541 0.0025 E136802400032 71.00 0.0127 0.0024 E136802400033 76.02 -0.1002 0.0036 E136802400034 81.04 -0.1740 0.0057 E136802400035 86.06 -0.0466 0.0044 E136802400036 91.06 0.1382 0.0061 E136802400037 96.06 0.0525 0.0058 E136802400038 101.04 -0.1446 0.0067 E136802400039 106.02 -0.2592 0.0087 E136802400040 111.00 -0.1480 0.0083 E136802400041 115.96 0.1743 0.0088 E136802400042 120.92 0.1706 0.0091 E136802400043 125.87 -0.0813 0.0071 E136802400044 130.81 -0.2327 0.0089 E136802400045 135.75 -0.2537 0.0104 E136802400046 140.68 -0.0857 0.0094 E136802400047 145.61 0.1945 0.0111 E136802400048 150.53 0.1796 0.0108 E136802400049 155.45 -0.0027 0.0102 E136802400050 ENDDATA 28 0 E136802400051 ENDSUBENT 50 0 E136802499999 SUBENT E1368025 20080131 E051E136802500001 BIB 7 13 E136802500002 REACTION (46-PD-110(D,EL)46-PD-110,,POL/DA,,VAP) E136802500003 EN-SEC ANG is polar angle between beam and deuteron in E136802500004 laboratory system E136802500005 SAMPLE - Target enrichment is 97.73%. E136802500006 - Target-thickness is 2.26 mg/cm**2. E136802500007 METHOD (EDE) E136802500008 DETECTOR Solid angle of detector is 2 msr. E136802500009 (MAGSP,SWPC) To momentum analyze and detect scattered E136802500010 deuteron E136802500011 ERR-ANALYS (ERR-T) Total uncertainty E136802500012 (ERR-1) Uncertainty due to measured beam polarizations E136802500013 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136802500014 doctor thesis of M.Takei E136802500015 ENDBIB 13 0 E136802500016 COMMON 3 3 E136802500017 EN ANG-ERR ERR-1 E136802500018 MEV ADEG PER-CENT E136802500019 21. 1.5 2. E136802500020 ENDCOMMON 3 0 E136802500021 DATA 3 25 E136802500022 ANG-CM DATA ERR-T E136802500023 ADEG NO-DIM NO-DIM E136802500024 50.80 -0.0545 0.0030 E136802500025 55.85 -0.0617 0.0046 E136802500026 60.90 0.0036 0.0039 E136802500027 65.94 0.0348 0.0042 E136802500028 70.98 0.0001 0.0042 E136802500029 76.01 -0.1079 0.0062 E136802500030 81.03 -0.1461 0.0063 E136802500031 86.04 -0.0059 0.0064 E136802500032 91.04 0.1242 0.0077 E136802500033 96.04 0.0071 0.0078 E136802500034 101.03 -0.1675 0.0094 E136802500035 106.01 -0.2281 0.0116 E136802500036 110.98 -0.0694 0.0114 E136802500037 115.94 0.2160 0.0118 E136802500038 120.90 0.0987 0.0118 E136802500039 125.85 -0.1433 0.0117 E136802500040 130.80 -0.2167 0.0131 E136802500041 135.74 -0.1793 0.0136 E136802500042 140.67 -0.0040 0.0115 E136802500043 145.60 0.1914 0.0136 E136802500044 150.52 0.1024 0.0128 E136802500045 155.44 -0.0374 0.0119 E136802500046 160.36 -0.1296 0.0126 E136802500047 165.27 -0.1526 0.0135 E136802500048 170.18 -0.1343 0.0159 E136802500049 ENDDATA 27 0 E136802500050 ENDSUBENT 49 0 E136802599999 SUBENT E1368026 20080131 E051E136802600001 BIB 7 14 E136802600002 REACTION (20-CA-40(D,EL)20-CA-40,20,POL/DA,,TAP) E136802600003 EN-SEC ANG is polar angle between beam and deuteron in E136802600004 laboratory system E136802600005 SAMPLE - Target is natural. E136802600006 - Target-thickness is 0.51 mg/cm**2. E136802600007 - Backing is mylar film. E136802600008 - Backing-thickness: 1-micro meter E136802600009 METHOD (EDE) E136802600010 DETECTOR Solid angle of detector is 1.83 msr. E136802600011 (TELES) To detect scattered deuteron E136802600012 ERR-ANALYS (ERR-T) Total uncertainty E136802600013 (ERR-1) Uncertainty due to measured beam polarizations E136802600014 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136802600015 doctor thesis of M.Takei E136802600016 ENDBIB 14 0 E136802600017 COMMON 4 3 E136802600018 EN E-RSL ANG-ERR ERR-1 E136802600019 MEV KEV ADEG PER-CENT E136802600020 22. 90. 1.3 2. E136802600021 ENDCOMMON 3 0 E136802600022 DATA 3 24 E136802600023 ANG-CM DATA ERR-T E136802600024 ADEG NO-DIM NO-DIM E136802600025 57.35 0.0465 0.0178 E136802600026 62.48 0.0366 0.0240 E136802600027 67.60 -0.1196 0.0290 E136802600028 72.69 -0.4861 0.0324 E136802600029 77.77 -0.0596 0.0242 E136802600030 82.82 0.1298 0.0335 E136802600031 87.86 0.1279 0.0158 E136802600032 92.87 0.0140 0.0164 E136802600033 97.86 -0.1832 0.0253 E136802600034 102.82 -0.3551 0.0310 E136802600035 107.77 -0.2898 0.0255 E136802600036 112.69 -0.2041 0.0257 E136802600037 117.60 -0.0404 0.0283 E136802600038 122.48 0.0440 0.0285 E136802600039 127.35 0.0985 0.0303 E136802600040 132.20 0.0564 0.0331 E136802600041 137.03 -0.1834 0.0344 E136802600042 141.84 -0.4452 0.0374 E136802600043 146.64 -0.5701 0.0442 E136802600044 151.43 -0.4326 0.0547 E136802600045 156.21 0.1351 0.0403 E136802600046 160.98 -0.0475 0.0353 E136802600047 165.74 -0.2197 0.0326 E136802600048 170.50 -0.3007 0.0402 E136802600049 ENDDATA 26 0 E136802600050 ENDSUBENT 49 0 E136802699999 SUBENT E1368027 20080131 E051E136802700001 BIB 7 12 E136802700002 REACTION (28-NI-58(D,EL)28-NI-58,20,POL/DA,,TAP) E136802700003 EN-SEC ANG is polar angle between beam and deuteron in E136802700004 laboratory system E136802700005 SAMPLE - Target enrichment is 99.89%. E136802700006 - Target-thickness is 0.98 mg/cm**2. E136802700007 METHOD (EDE) E136802700008 DETECTOR Solid angle of detector is 1.83 msr. E136802700009 (TELES) To detect scattered deuteron E136802700010 ERR-ANALYS (ERR-T) Total uncertainty E136802700011 (ERR-1) Uncertainty due to measured beam polarizations E136802700012 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136802700013 doctor thesis of M.Takei E136802700014 ENDBIB 12 0 E136802700015 COMMON 4 3 E136802700016 EN E-RSL ANG-ERR ERR-1 E136802700017 MEV KEV ADEG PER-CENT E136802700018 22. 90. 1.3 2. E136802700019 ENDCOMMON 3 0 E136802700020 DATA 3 29 E136802700021 ANG-CM DATA ERR-T E136802700022 ADEG NO-DIM NO-DIM E136802700023 30.99 -0.0143 0.0080 E136802700024 36.13 -0.0177 0.0095 E136802700025 41.27 -0.0381 0.0131 E136802700026 46.40 -0.0171 0.0109 E136802700027 51.51 -0.0553 0.0200 E136802700028 56.62 -0.0438 0.0236 E136802700029 61.71 -0.0005 0.0375 E136802700030 66.79 0.0175 0.0250 E136802700031 71.86 0.0124 0.0150 E136802700032 76.91 -0.0718 0.0186 E136802700033 81.95 -0.2240 0.0285 E136802700034 86.97 -0.4915 0.0649 E136802700035 91.98 0.0107 0.0497 E136802700036 96.97 0.0867 0.0369 E136802700037 101.95 0.0635 0.0359 E136802700038 106.91 -0.0701 0.0417 E136802700039 111.86 -0.3528 0.0640 E136802700040 116.79 -0.6602 0.0924 E136802700041 121.71 0.2057 0.0992 E136802700042 126.62 0.3594 0.0987 E136802700043 131.51 0.1761 0.0897 E136802700044 136.40 0.2774 0.0881 E136802700045 141.27 -0.2174 0.0683 E136802700046 146.13 -0.4515 0.0787 E136802700047 150.99 -0.6145 0.0957 E136802700048 155.84 0.0244 0.1113 E136802700049 160.68 0.2472 0.0875 E136802700050 165.51 -0.0397 0.0682 E136802700051 170.34 -0.0242 0.0681 E136802700052 ENDDATA 31 0 E136802700053 ENDSUBENT 52 0 E136802799999 SUBENT E1368028 20080131 E051E136802800001 BIB 7 12 E136802800002 REACTION (28-NI-60(D,EL)28-NI-60,20,POL/DA,,TAP) E136802800003 EN-SEC ANG is polar angle between beam and deuteron in E136802800004 laboratory system E136802800005 SAMPLE - Target enrichment is 99.79%. E136802800006 - Target-thickness is 0.95 mg/cm**2. E136802800007 METHOD (EDE) E136802800008 DETECTOR Solid angle of detector is 1.83 msr. E136802800009 (TELES) To detect scattered deuteron E136802800010 ERR-ANALYS (ERR-T) Total uncertainty E136802800011 (ERR-1) Uncertainty due to measured beam polarizations E136802800012 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136802800013 doctor thesis of M.Takei E136802800014 ENDBIB 12 0 E136802800015 COMMON 4 3 E136802800016 EN E-RSL ANG-ERR ERR-1 E136802800017 MEV KEV ADEG PER-CENT E136802800018 22. 90. 1.3 2. E136802800019 ENDCOMMON 3 0 E136802800020 DATA 3 27 E136802800021 ANG-CM DATA ERR-T E136802800022 ADEG NO-DIM NO-DIM E136802800023 41.23 0.0062 0.0098 E136802800024 46.35 -0.0190 0.0116 E136802800025 51.46 -0.0107 0.0137 E136802800026 56.56 0.0035 0.0234 E136802800027 61.65 0.0811 0.0424 E136802800028 66.73 0.0213 0.0287 E136802800029 71.79 -0.0099 0.0223 E136802800030 76.85 -0.0965 0.0304 E136802800031 81.88 -0.2255 0.0359 E136802800032 86.90 -0.1603 0.0507 E136802800033 91.91 0.1421 0.0303 E136802800034 96.90 0.0937 0.0249 E136802800035 101.88 0.0008 0.0258 E136802800036 106.85 -0.1761 0.0414 E136802800037 111.80 -0.4513 0.0662 E136802800038 116.73 -0.3325 0.0670 E136802800039 121.65 0.1009 0.0541 E136802800040 126.56 0.2542 0.0529 E136802800041 131.46 0.1900 0.0424 E136802800042 136.35 0.0543 0.0424 E136802800043 141.23 -0.2498 0.0738 E136802800044 146.10 -0.5361 0.0935 E136802800045 150.96 -0.2486 0.0827 E136802800046 155.81 0.2376 0.0609 E136802800047 160.65 0.2736 0.0569 E136802800048 165.49 0.0500 0.0454 E136802800049 170.33 -0.0562 0.0447 E136802800050 ENDDATA 29 0 E136802800051 ENDSUBENT 50 0 E136802899999 SUBENT E1368029 20080131 E051E136802900001 BIB 7 12 E136802900002 REACTION (28-NI-62(D,EL)28-NI-62,20,POL/DA,,TAP) E136802900003 EN-SEC ANG is polar angle between beam and deuteron in E136802900004 laboratory system E136802900005 SAMPLE - Target enrichment is 98.70%. E136802900006 - Target-thickness is 1.12 mg/cm**2. E136802900007 METHOD (EDE) E136802900008 DETECTOR Solid angle of detector is 1.83 msr. E136802900009 (TELES) To detect scattered deuteron E136802900010 ERR-ANALYS (ERR-T) Total uncertainty E136802900011 (ERR-1) Uncertainty due to measured beam polarizations E136802900012 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136802900013 doctor thesis of M.Takei E136802900014 ENDBIB 12 0 E136802900015 COMMON 4 3 E136802900016 EN E-RSL ANG-ERR ERR-1 E136802900017 MEV KEV ADEG PER-CENT E136802900018 22. 90. 1.3 2. E136802900019 ENDCOMMON 3 0 E136802900020 DATA 3 28 E136802900021 ANG-CM DATA ERR-T E136802900022 ADEG NO-DIM NO-DIM E136802900023 36.06 0.0123 0.0073 E136802900024 41.19 -0.0122 0.0075 E136802900025 46.31 0.0011 0.0088 E136802900026 51.42 0.0574 0.0208 E136802900027 56.51 0.0183 0.0322 E136802900028 61.60 0.0711 0.0271 E136802900029 66.68 0.0169 0.0188 E136802900030 71.74 -0.0119 0.0150 E136802900031 76.79 -0.1220 0.0209 E136802900032 81.82 -0.2173 0.0488 E136802900033 86.84 -0.0517 0.0493 E136802900034 91.85 0.0848 0.0401 E136802900035 96.84 0.0843 0.0325 E136802900036 101.82 -0.0337 0.0362 E136802900037 106.79 -0.2127 0.0523 E136802900038 111.74 -0.3056 0.0993 E136802900039 116.68 -0.1425 0.0832 E136802900040 121.60 0.1789 0.0804 E136802900041 126.51 0.0996 0.0785 E136802900042 131.42 -0.0083 0.0819 E136802900043 136.31 -0.1010 0.0628 E136802900044 141.19 -0.3463 0.0736 E136802900045 146.06 -0.4396 0.0894 E136802900046 150.92 -0.1186 0.1007 E136802900047 155.78 0.3268 0.1135 E136802900048 160.63 0.2329 0.0842 E136802900049 165.48 -0.1101 0.0607 E136802900050 170.32 -0.3573 0.0581 E136802900051 ENDDATA 30 0 E136802900052 ENDSUBENT 51 0 E136802999999 SUBENT E1368030 20080131 E051E136803000001 BIB 7 12 E136803000002 REACTION (28-NI-64(D,EL)28-NI-64,20,POL/DA,,TAP) E136803000003 EN-SEC ANG is polar angle between beam and deuteron in E136803000004 laboratory system E136803000005 SAMPLE - Target enrichment is 96.48%. E136803000006 - Target-thickness is 0.82 mg/cm**2. E136803000007 METHOD (EDE) E136803000008 DETECTOR Solid angle of detector is 1.83 msr. E136803000009 (TELES) To detect scattered deuteron E136803000010 ERR-ANALYS (ERR-T) Total uncertainty E136803000011 (ERR-1) Uncertainty due to measured beam polarizations E136803000012 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136803000013 doctor thesis of M.Takei E136803000014 ENDBIB 12 0 E136803000015 COMMON 4 3 E136803000016 EN E-RSL ANG-ERR ERR-1 E136803000017 MEV KEV ADEG PER-CENT E136803000018 22. 90. 1.3 2. E136803000019 ENDCOMMON 3 0 E136803000020 DATA 3 29 E136803000021 ANG-CM DATA ERR-T E136803000022 ADEG NO-DIM NO-DIM E136803000023 30.90 0.0159 0.0078 E136803000024 36.03 -0.0083 0.0080 E136803000025 41.15 0.0091 0.0091 E136803000026 46.27 -0.0405 0.0114 E136803000027 51.37 -0.0597 0.0291 E136803000028 56.47 -0.0253 0.0381 E136803000029 61.55 0.0824 0.0292 E136803000030 66.62 0.0147 0.0219 E136803000031 71.68 -0.0112 0.0163 E136803000032 76.73 -0.1267 0.0313 E136803000033 81.76 -0.3300 0.0653 E136803000034 86.78 0.0939 0.0389 E136803000035 91.79 0.0784 0.0307 E136803000036 96.78 -0.0102 0.0383 E136803000037 101.76 -0.1050 0.0483 E136803000038 106.73 -0.3208 0.0588 E136803000039 111.68 -0.3629 0.0748 E136803000040 116.62 0.0460 0.0875 E136803000041 121.55 0.1834 0.0802 E136803000042 126.47 0.1429 0.0772 E136803000043 131.37 -0.0711 0.0876 E136803000044 136.27 -0.4253 0.0674 E136803000045 141.15 -0.5963 0.0972 E136803000046 146.03 -0.4782 0.0869 E136803000047 150.90 0.3424 0.1085 E136803000048 155.76 0.6003 0.1207 E136803000049 160.61 0.3073 0.0873 E136803000050 165.46 -0.0525 0.0663 E136803000051 170.31 -0.5290 0.0630 E136803000052 ENDDATA 31 0 E136803000053 ENDSUBENT 52 0 E136803099999 SUBENT E1368031 20080131 E051E136803100001 BIB 7 12 E136803100002 REACTION (40-ZR-90(D,EL)40-ZR-90,20,POL/DA,,TAP) E136803100003 EN-SEC ANG is polar angle between beam and deuteron in E136803100004 laboratory system E136803100005 SAMPLE - Target enrichment is 97.62%. E136803100006 - Target-thickness is 1.00 mg/cm**2. E136803100007 METHOD (EDE) E136803100008 DETECTOR Solid angle of detector is 1.83 msr. E136803100009 (TELES) To detect scattered deuteron E136803100010 ERR-ANALYS (ERR-T) Total uncertainty E136803100011 (ERR-1) Uncertainty due to measured beam polarizations E136803100012 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136803100013 doctor thesis of M.Takei E136803100014 ENDBIB 12 0 E136803100015 COMMON 4 3 E136803100016 EN E-RSL ANG-ERR ERR-1 E136803100017 MEV KEV ADEG PER-CENT E136803100018 22. 90. 1.3 2. E136803100019 ENDCOMMON 3 0 E136803100020 DATA 3 26 E136803100021 ANG-CM DATA ERR-T E136803100022 ADEG NO-DIM NO-DIM E136803100023 40.82 0.0207 0.0054 E136803100024 50.98 0.0241 0.0050 E136803100025 56.04 -0.0002 0.0047 E136803100026 61.10 -0.0267 0.0078 E136803100027 66.15 -0.0984 0.0120 E136803100028 71.20 0.0473 0.0116 E136803100029 76.23 0.0430 0.0104 E136803100030 81.25 -0.0147 0.0103 E136803100031 86.27 -0.1393 0.0133 E136803100032 91.27 -0.3293 0.0172 E136803100033 96.27 -0.0909 0.0144 E136803100034 101.25 0.1842 0.0108 E136803100035 106.23 0.0163 0.0088 E136803100036 111.20 -0.1082 0.0105 E136803100037 116.15 -0.3966 0.0171 E136803100038 121.10 -0.3317 0.0205 E136803100039 126.04 0.1057 0.0154 E136803100040 130.98 0.2233 0.0126 E136803100041 135.90 0.1002 0.0110 E136803100042 140.82 -0.1616 0.0140 E136803100043 145.73 -0.4372 0.0207 E136803100044 150.64 -0.5165 0.0278 E136803100045 155.54 -0.0036 0.0173 E136803100046 160.44 0.3212 0.0177 E136803100047 165.33 0.0083 0.0097 E136803100048 170.22 -0.2382 0.0154 E136803100049 ENDDATA 28 0 E136803100050 ENDSUBENT 49 0 E136803199999 SUBENT E1368032 20080131 E051E136803200001 BIB 7 12 E136803200002 REACTION (42-MO-92(D,EL)42-MO-92,20,POL/DA,,TAP) E136803200003 EN-SEC ANG is polar angle between beam and deuteron in E136803200004 laboratory system E136803200005 SAMPLE - Target enrichment is 95.13%. E136803200006 - Target-thickness is 1.62 mg/cm**2. E136803200007 METHOD (EDE) E136803200008 DETECTOR Solid angle of detector is 1.83 msr. E136803200009 (TELES) To detect scattered deuteron E136803200010 ERR-ANALYS (ERR-T) Total uncertainty E136803200011 (ERR-1) Uncertainty due to measured beam polarizations E136803200012 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136803200013 doctor thesis of M.Takei E136803200014 ENDBIB 12 0 E136803200015 COMMON 4 3 E136803200016 EN E-RSL ANG-ERR ERR-1 E136803200017 MEV KEV ADEG PER-CENT E136803200018 22. 90. 1.3 2. E136803200019 ENDCOMMON 3 0 E136803200020 DATA 3 27 E136803200021 ANG-CM DATA ERR-T E136803200022 ADEG NO-DIM NO-DIM E136803200023 40.80 -0.0292 0.0130 E136803200024 45.88 0.0111 0.0127 E136803200025 50.95 0.0118 0.0165 E136803200026 56.02 0.0005 0.0266 E136803200027 61.08 -0.0570 0.0274 E136803200028 66.13 -0.0275 0.0418 E136803200029 71.17 0.0470 0.0347 E136803200030 76.20 0.0436 0.0234 E136803200031 81.23 -0.0351 0.0220 E136803200032 86.24 -0.1338 0.0231 E136803200033 91.25 -0.2451 0.0543 E136803200034 96.24 0.0117 0.0685 E136803200035 101.23 0.1911 0.0581 E136803200036 106.20 0.0460 0.0390 E136803200037 111.17 -0.1398 0.0285 E136803200038 116.13 -0.4594 0.0607 E136803200039 121.08 -0.2731 0.0883 E136803200040 126.02 0.1195 0.0930 E136803200041 130.95 0.1507 0.0610 E136803200042 135.88 0.1234 0.0451 E136803200043 140.80 -0.0864 0.0506 E136803200044 145.71 -0.3980 0.0658 E136803200045 150.62 -0.4742 0.0787 E136803200046 155.53 0.1379 0.1033 E136803200047 160.43 0.4254 0.1003 E136803200048 165.32 0.0411 0.0697 E136803200049 170.22 -0.0854 0.0592 E136803200050 ENDDATA 29 0 E136803200051 ENDSUBENT 50 0 E136803299999 SUBENT E1368033 20080131 E051E136803300001 BIB 7 12 E136803300002 REACTION (42-MO-100(D,EL)42-MO-100,20,POL/DA,,TAP) E136803300003 EN-SEC ANG is polar angle between beam and deuteron in E136803300004 laboratory system E136803300005 SAMPLE - Target enrichment is 97.27%. E136803300006 - Target-thickness is 1.52 mg/cm**2. E136803300007 METHOD (EDE) E136803300008 DETECTOR Solid angle of detector is 1.83 msr. E136803300009 (TELES) To detect scattered deuteron E136803300010 ERR-ANALYS (ERR-T) Total uncertainty E136803300011 (ERR-1) Uncertainty due to measured beam polarizations E136803300012 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136803300013 doctor thesis of M.Takei E136803300014 ENDBIB 12 0 E136803300015 COMMON 4 3 E136803300016 EN E-RSL ANG-ERR ERR-1 E136803300017 MEV KEV ADEG PER-CENT E136803300018 22. 90. 1.3 2. E136803300019 ENDCOMMON 3 0 E136803300020 DATA 3 29 E136803300021 ANG-CM DATA ERR-T E136803300022 ADEG NO-DIM NO-DIM E136803300023 30.57 0.0015 0.0055 E136803300024 35.66 0.0652 0.0091 E136803300025 40.74 0.0136 0.0100 E136803300026 45.81 0.0356 0.0097 E136803300027 50.88 0.0073 0.0199 E136803300028 55.94 0.0092 0.0277 E136803300029 60.99 0.0053 0.0319 E136803300030 66.04 0.0493 0.0330 E136803300031 71.08 0.0132 0.0223 E136803300032 76.11 0.0208 0.0256 E136803300033 81.13 -0.0776 0.0302 E136803300034 86.14 -0.1003 0.0389 E136803300035 91.15 0.0465 0.0566 E136803300036 96.14 0.0393 0.0672 E136803300037 101.13 -0.0413 0.0586 E136803300038 106.11 -0.0890 0.0562 E136803300039 111.08 -0.0906 0.0790 E136803300040 116.04 -0.2695 0.1273 E136803300041 120.99 0.1839 0.1372 E136803300042 125.94 0.0175 0.1209 E136803300043 130.88 -0.0637 0.0944 E136803300044 135.81 -0.1603 0.0845 E136803300045 140.74 -0.3874 0.1072 E136803300046 145.66 -0.2123 0.1409 E136803300047 150.57 -0.0173 0.1574 E136803300048 155.48 0.3676 0.1468 E136803300049 160.39 0.1066 0.1307 E136803300050 165.30 0.0884 0.1302 E136803300051 170.20 -0.1110 0.1318 E136803300052 ENDDATA 31 0 E136803300053 ENDSUBENT 52 0 E136803399999 SUBENT E1368034 20080131 E051E136803400001 BIB 7 13 E136803400002 REACTION (46-PD-104(D,EL)46-PD-104,20,POL/DA,,TAP) E136803400003 EN-SEC ANG is polar angle between beam and deuteron in E136803400004 laboratory system E136803400005 SAMPLE - Target enrichment is 95.25%. E136803400006 - Target-thickness is 3.25 mg/cm**2. E136803400007 METHOD (EDE) E136803400008 DETECTOR Solid angle of detector is 2 msr. E136803400009 (MAGSP,SWPC) To momentum analyze and detect scattered E136803400010 deuteron E136803400011 ERR-ANALYS (ERR-T) Total uncertainty E136803400012 (ERR-1) Uncertainty due to measured beam polarizations E136803400013 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136803400014 doctor thesis of M.Takei E136803400015 ENDBIB 13 0 E136803400016 COMMON 3 3 E136803400017 EN ANG-ERR ERR-1 E136803400018 MEV ADEG PER-CENT E136803400019 21. 1.5 2. E136803400020 ENDCOMMON 3 0 E136803400021 DATA 3 27 E136803400022 ANG-CM DATA ERR-T E136803400023 ADEG NO-DIM NO-DIM E136803400024 45.78 0.0018 0.0016 E136803400025 50.84 0.0026 0.0020 E136803400026 55.90 0.0045 0.0031 E136803400027 60.95 0.0065 0.0046 E136803400028 66.00 0.0096 0.0051 E136803400029 68.52 0.0045 0.0052 E136803400030 71.04 0.0035 0.0054 E136803400031 76.06 -0.0079 0.0067 E136803400032 81.09 -0.0333 0.0087 E136803400033 86.10 -0.0401 0.0089 E136803400034 91.10 0.0041 0.0115 E136803400035 96.10 0.1004 0.0133 E136803400036 101.09 -0.0229 0.0117 E136803400037 106.06 -0.0942 0.0115 E136803400038 111.04 -0.1338 0.0183 E136803400039 116.00 -0.0862 0.0183 E136803400040 120.95 0.1455 0.0189 E136803400041 125.90 0.1431 0.0140 E136803400042 130.84 0.0048 0.0137 E136803400043 135.78 -0.1355 0.0164 E136803400044 140.71 -0.1636 0.0206 E136803400045 145.63 -0.0517 0.0248 E136803400046 150.55 0.1500 0.0261 E136803400047 155.47 0.2579 0.0172 E136803400048 160.38 0.1176 0.0133 E136803400049 165.29 0.0077 0.0131 E136803400050 170.19 -0.1413 0.0149 E136803400051 ENDDATA 29 0 E136803400052 ENDSUBENT 51 0 E136803499999 SUBENT E1368035 20080131 E051E136803500001 BIB 7 13 E136803500002 REACTION (46-PD-106(D,EL)46-PD-106,20,POL/DA,,TAP) E136803500003 EN-SEC ANG is polar angle between beam and deuteron in E136803500004 laboratory system E136803500005 SAMPLE - Target enrichment is 96.66%. E136803500006 - Target-thickness is 3.42 mg/cm**2. E136803500007 METHOD (EDE) E136803500008 DETECTOR Solid angle of detector is 2 msr. E136803500009 (MAGSP,SWPC) To momentum analyze and detect scattered E136803500010 deuteron E136803500011 ERR-ANALYS (ERR-T) Total uncertainty E136803500012 (ERR-1) Uncertainty due to measured beam polarizations E136803500013 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136803500014 doctor thesis of M.Takei E136803500015 ENDBIB 13 0 E136803500016 COMMON 3 3 E136803500017 EN ANG-ERR ERR-1 E136803500018 MEV ADEG PER-CENT E136803500019 21. 1.5 2. E136803500020 ENDCOMMON 3 0 E136803500021 DATA 3 24 E136803500022 ANG-CM DATA ERR-T E136803500023 ADEG NO-DIM NO-DIM E136803500024 40.69 0.0100 0.0025 E136803500025 45.76 0.0012 0.0016 E136803500026 50.83 0.0004 0.0021 E136803500027 55.89 0.0049 0.0033 E136803500028 60.94 0.0105 0.0046 E136803500029 65.98 0.0142 0.0049 E136803500030 71.02 -0.0018 0.0051 E136803500031 76.04 -0.0250 0.0066 E136803500032 81.06 -0.0469 0.0087 E136803500033 86.08 -0.0067 0.0083 E136803500034 91.08 0.0477 0.0095 E136803500035 96.08 0.0541 0.0086 E136803500036 101.06 -0.0249 0.0091 E136803500037 106.04 -0.0952 0.0091 E136803500038 111.02 -0.1380 0.0127 E136803500039 115.98 0.0331 0.0145 E136803500040 120.94 0.1372 0.0147 E136803500041 125.89 0.0724 0.0139 E136803500042 130.83 -0.0344 0.0144 E136803500043 135.76 -0.1233 0.0171 E136803500044 140.69 -0.1484 0.0221 E136803500045 145.62 -0.0180 0.0244 E136803500046 150.54 0.1954 0.0241 E136803500047 155.46 0.1522 0.0234 E136803500048 ENDDATA 26 0 E136803500049 ENDSUBENT 48 0 E136803599999 SUBENT E1368036 20080131 E051E136803600001 BIB 7 13 E136803600002 REACTION (46-PD-108(D,EL)46-PD-108,20,POL/DA,,TAP) E136803600003 EN-SEC ANG is polar angle between beam and deuteron in E136803600004 laboratory system E136803600005 SAMPLE - Target enrichment is 98.11%. E136803600006 - Target-thickness is 3.26 mg/cm**2. E136803600007 METHOD (EDE) E136803600008 DETECTOR Solid angle of detector is 2 msr. E136803600009 (MAGSP,SWPC) To momentum analyze and detect scattered E136803600010 deuteron E136803600011 ERR-ANALYS (ERR-T) Total uncertainty E136803600012 (ERR-1) Uncertainty due to measured beam polarizations E136803600013 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136803600014 doctor thesis of M.Takei E136803600015 ENDBIB 13 0 E136803600016 COMMON 3 3 E136803600017 EN ANG-ERR ERR-1 E136803600018 MEV ADEG PER-CENT E136803600019 21. 1.5 2. E136803600020 ENDCOMMON 3 0 E136803600021 DATA 3 27 E136803600022 ANG-CM DATA ERR-T E136803600023 ADEG NO-DIM NO-DIM E136803600024 40.68 0.0036 0.0015 E136803600025 45.75 0.0003 0.0017 E136803600026 50.81 0.0008 0.0023 E136803600027 55.87 0.0058 0.0036 E136803600028 60.92 0.0063 0.0046 E136803600029 65.96 0.0038 0.0041 E136803600030 71.00 0.0039 0.0048 E136803600031 76.02 -0.0133 0.0044 E136803600032 81.04 -0.0245 0.0058 E136803600033 86.06 -0.0221 0.0074 E136803600034 91.06 0.0268 0.0086 E136803600035 96.06 -0.0020 0.0100 E136803600036 101.04 -0.0351 0.0094 E136803600037 106.02 -0.0935 0.0096 E136803600038 111.00 -0.0998 0.0111 E136803600039 115.96 0.0219 0.0135 E136803600040 120.92 0.0664 0.0122 E136803600041 125.87 0.0084 0.0110 E136803600042 130.81 -0.0636 0.0105 E136803600043 135.75 -0.1053 0.0124 E136803600044 140.68 -0.0437 0.0151 E136803600045 145.61 0.1181 0.0170 E136803600046 150.53 0.1218 0.0128 E136803600047 155.45 0.0774 0.0121 E136803600048 160.36 0.0218 0.0120 E136803600049 165.27 -0.0379 0.0104 E136803600050 170.18 -0.0501 0.0117 E136803600051 ENDDATA 29 0 E136803600052 ENDSUBENT 51 0 E136803699999 SUBENT E1368037 20080131 E051E136803700001 BIB 7 13 E136803700002 REACTION (46-PD-110(D,EL)46-PD-110,20,POL/DA,,TAP) E136803700003 EN-SEC ANG is polar angle between beam and deuteron in E136803700004 laboratory system E136803700005 SAMPLE - Target enrichment is 97.73%. E136803700006 - Target-thickness is 2.26 mg/cm**2. E136803700007 METHOD (EDE) E136803700008 DETECTOR Solid angle of detector is 2 msr. E136803700009 (MAGSP,SWPC) To momentum analyze and detect scattered E136803700010 deuteron E136803700011 ERR-ANALYS (ERR-T) Total uncertainty E136803700012 (ERR-1) Uncertainty due to measured beam polarizations E136803700013 STATUS (TABLE) Data (Fig.1, p45 in main reference) taken from E136803700014 doctor thesis of M.Takei E136803700015 ENDBIB 13 0 E136803700016 COMMON 3 3 E136803700017 EN ANG-ERR ERR-1 E136803700018 MEV ADEG PER-CENT E136803700019 21. 1.5 2. E136803700020 ENDCOMMON 3 0 E136803700021 DATA 3 23 E136803700022 ANG-CM DATA ERR-T E136803700023 ADEG NO-DIM NO-DIM E136803700024 60.90 0.0064 0.0050 E136803700025 65.94 0.0101 0.0053 E136803700026 70.98 0.0041 0.0044 E136803700027 76.01 -0.0012 0.0055 E136803700028 81.03 -0.0120 0.0052 E136803700029 86.04 -0.0279 0.0068 E136803700030 91.04 -0.0071 0.0065 E136803700031 96.04 0.0332 0.0076 E136803700032 101.03 0.0081 0.0084 E136803700033 106.01 -0.0332 0.0093 E136803700034 110.98 -0.0621 0.0128 E136803700035 115.94 -0.0819 0.0135 E136803700036 120.90 0.0189 0.0136 E136803700037 125.85 0.0442 0.0142 E136803700038 130.80 -0.0065 0.0137 E136803700039 135.74 -0.0808 0.0150 E136803700040 140.67 -0.1103 0.0161 E136803700041 145.60 -0.0102 0.0157 E136803700042 150.52 0.0831 0.0144 E136803700043 155.44 0.1030 0.0138 E136803700044 160.36 0.0335 0.0131 E136803700045 165.27 0.0031 0.0134 E136803700046 170.18 -0.0527 0.0126 E136803700047 ENDDATA 25 0 E136803700048 ENDSUBENT 47 0 E136803799999 SUBENT E1368038 20080131 E051E136803800001 BIB 7 14 E136803800002 REACTION (20-CA-40(D,EL)20-CA-40,21,POL/DA,,TAP) E136803800003 EN-SEC ANG is polar angle between beam and deuteron in E136803800004 laboratory system E136803800005 SAMPLE - Target is natural. E136803800006 - Target-thickness is 0.51 mg/cm**2. E136803800007 - Backing is mylar film. E136803800008 - Backing-thickness: 1-micro meter E136803800009 METHOD (EDE) E136803800010 DETECTOR Solid angle of detector is 1.83 msr. E136803800011 (TELES) To detect scattered deuteron E136803800012 ERR-ANALYS (ERR-T) Total uncertainty E136803800013 (ERR-1) Uncertainty due to measured beam polarizations E136803800014 STATUS (TABLE) Data (Fig.1, p46 in main reference) taken from E136803800015 doctor thesis of M.Takei E136803800016 ENDBIB 14 0 E136803800017 COMMON 4 3 E136803800018 EN E-RSL ANG-ERR ERR-1 E136803800019 MEV KEV ADEG PER-CENT E136803800020 22. 90. 1.3 2. E136803800021 ENDCOMMON 3 0 E136803800022 DATA 3 24 E136803800023 ANG-CM DATA ERR-T E136803800024 ADEG NO-DIM NO-DIM E136803800025 57.35 -0.0049 0.0057 E136803800026 62.48 -0.0496 0.0081 E136803800027 67.60 -0.0794 0.0095 E136803800028 72.69 -0.0405 0.0107 E136803800029 77.77 0.0114 0.0074 E136803800030 82.82 -0.0092 0.0060 E136803800031 87.86 -0.0258 0.0044 E136803800032 92.87 -0.0223 0.0049 E136803800033 97.86 0.0222 0.0080 E136803800034 102.82 0.0405 0.0092 E136803800035 107.77 0.0360 0.0071 E136803800036 112.69 0.0127 0.0072 E136803800037 117.60 0.0116 0.0085 E136803800038 122.48 0.0134 0.0085 E136803800039 127.35 0.0162 0.0087 E136803800040 132.20 0.0534 0.0092 E136803800041 137.03 0.0927 0.0100 E136803800042 141.84 0.1313 0.0111 E136803800043 146.64 0.0881 0.0132 E136803800044 151.43 0.1023 0.0116 E136803800045 156.21 0.0565 0.0118 E136803800046 160.98 0.1147 0.0104 E136803800047 165.74 0.1984 0.0103 E136803800048 170.50 0.2542 0.0111 E136803800049 ENDDATA 26 0 E136803800050 ENDSUBENT 49 0 E136803899999 SUBENT E1368039 20080131 E051E136803900001 BIB 7 12 E136803900002 REACTION (28-NI-58(D,EL)28-NI-58,21,POL/DA,,TAP) E136803900003 EN-SEC ANG is polar angle between beam and deuteron in E136803900004 laboratory system E136803900005 SAMPLE - Target enrichment is 99.89%. E136803900006 - Target-thickness is 0.98 mg/cm**2. E136803900007 METHOD (EDE) E136803900008 DETECTOR Solid angle of detector is 1.83 msr. E136803900009 (TELES) To detect scattered deuteron E136803900010 ERR-ANALYS (ERR-T) Total uncertainty E136803900011 (ERR-1) Uncertainty due to measured beam polarizations E136803900012 STATUS (TABLE) Data (Fig.1, p46 in main reference) taken from E136803900013 doctor thesis of M.Takei E136803900014 ENDBIB 12 0 E136803900015 COMMON 4 3 E136803900016 EN E-RSL ANG-ERR ERR-1 E136803900017 MEV KEV ADEG PER-CENT E136803900018 22. 90. 1.3 2. E136803900019 ENDCOMMON 3 0 E136803900020 DATA 3 29 E136803900021 ANG-CM DATA ERR-T E136803900022 ADEG NO-DIM NO-DIM E136803900023 30.99 -0.0004 0.0020 E136803900024 36.13 -0.0017 0.0020 E136803900025 41.27 -0.0018 0.0019 E136803900026 46.40 0.0004 0.0021 E136803900027 51.51 -0.0152 0.0057 E136803900028 56.62 -0.0361 0.0064 E136803900029 61.71 -0.0274 0.0089 E136803900030 66.79 0.0298 0.0062 E136803900031 71.86 0.0111 0.0032 E136803900032 76.91 -0.0130 0.0038 E136803900033 81.95 -0.0389 0.0062 E136803900034 86.97 -0.0386 0.0135 E136803900035 91.98 0.0340 0.0116 E136803900036 96.97 0.0079 0.0087 E136803900037 101.95 -0.0229 0.0084 E136803900038 106.91 -0.0277 0.0102 E136803900039 111.86 0.0092 0.0168 E136803900040 116.79 0.0761 0.0236 E136803900041 121.71 0.0238 0.0237 E136803900042 126.62 0.0293 0.0217 E136803900043 131.51 0.0034 0.0149 E136803900044 136.40 -0.0038 0.0152 E136803900045 141.27 0.0582 0.0164 E136803900046 146.13 0.1533 0.0183 E136803900047 150.99 0.1228 0.0230 E136803900048 155.84 0.1053 0.0258 E136803900049 160.68 0.0933 0.0195 E136803900050 165.51 0.1042 0.0156 E136803900051 170.34 0.1253 0.0165 E136803900052 ENDDATA 31 0 E136803900053 ENDSUBENT 52 0 E136803999999 SUBENT E1368040 20080131 E051E136804000001 BIB 7 12 E136804000002 REACTION (28-NI-60(D,EL)28-NI-60,21,POL/DA,,TAP) E136804000003 EN-SEC ANG is polar angle between beam and deuteron in E136804000004 laboratory system E136804000005 SAMPLE - Target enrichment is 99.79%. E136804000006 - Target-thickness is 0.95 mg/cm**2. E136804000007 METHOD (EDE) E136804000008 DETECTOR Solid angle of detector is 1.83 msr. E136804000009 (TELES) To detect scattered deuteron E136804000010 ERR-ANALYS (ERR-T) Total uncertainty E136804000011 (ERR-1) Uncertainty due to measured beam polarizations E136804000012 STATUS (TABLE) Data (Fig.1, p46 in main reference) taken from E136804000013 doctor thesis of M.Takei E136804000014 ENDBIB 12 0 E136804000015 COMMON 4 3 E136804000016 EN E-RSL ANG-ERR ERR-1 E136804000017 MEV KEV ADEG PER-CENT E136804000018 22. 90. 1.3 2. E136804000019 ENDCOMMON 3 0 E136804000020 DATA 3 28 E136804000021 ANG-CM DATA ERR-T E136804000022 ADEG NO-DIM NO-DIM E136804000023 36.10 -0.0068 0.0018 E136804000024 41.23 -0.0068 0.0016 E136804000025 46.35 -0.0071 0.0019 E136804000026 51.46 -0.0297 0.0039 E136804000027 56.56 -0.0385 0.0067 E136804000028 61.65 0.0036 0.0071 E136804000029 66.73 0.0235 0.0044 E136804000030 71.79 -0.0039 0.0029 E136804000031 76.85 -0.0212 0.0038 E136804000032 81.88 -0.0391 0.0071 E136804000033 86.90 -0.0055 0.0135 E136804000034 91.91 0.0115 0.0085 E136804000035 96.90 -0.0099 0.0071 E136804000036 101.88 -0.0282 0.0080 E136804000037 106.85 -0.0152 0.0108 E136804000038 111.80 0.1161 0.0195 E136804000039 116.73 0.1034 0.0234 E136804000040 121.65 0.0109 0.0225 E136804000041 126.56 -0.0043 0.0198 E136804000042 131.46 -0.0051 0.0194 E136804000043 136.35 0.0580 0.0146 E136804000044 141.23 0.1430 0.0159 E136804000045 146.10 0.2428 0.0190 E136804000046 150.96 0.2278 0.0241 E136804000047 155.81 0.0540 0.0242 E136804000048 160.65 0.0030 0.0186 E136804000049 165.49 0.1027 0.0153 E136804000050 170.33 0.1408 0.0147 E136804000051 ENDDATA 30 0 E136804000052 ENDSUBENT 51 0 E136804099999 SUBENT E1368041 20080131 E051E136804100001 BIB 7 12 E136804100002 REACTION (28-NI-62(D,EL)28-NI-62,21,POL/DA,,TAP) E136804100003 EN-SEC ANG is polar angle between beam and deuteron in E136804100004 laboratory system E136804100005 SAMPLE - Target enrichment is 98.70%. E136804100006 - Target-thickness is 1.12 mg/cm**2. E136804100007 METHOD (EDE) E136804100008 DETECTOR Solid angle of detector is 1.83 msr. E136804100009 (TELES) To detect scattered deuteron E136804100010 ERR-ANALYS (ERR-T) Total uncertainty E136804100011 (ERR-1) Uncertainty due to measured beam polarizations E136804100012 STATUS (TABLE) Data (Fig.1, p46 in main reference) taken from E136804100013 doctor thesis of M.Takei E136804100014 ENDBIB 12 0 E136804100015 COMMON 4 3 E136804100016 EN E-RSL ANG-ERR ERR-1 E136804100017 MEV KEV ADEG PER-CENT E136804100018 22. 90. 1.3 2. E136804100019 ENDCOMMON 3 0 E136804100020 DATA 3 28 E136804100021 ANG-CM DATA ERR-T E136804100022 ADEG NO-DIM NO-DIM E136804100023 36.06 -0.0098 0.0018 E136804100024 41.19 -0.0082 0.0017 E136804100025 46.31 -0.0108 0.0020 E136804100026 51.42 -0.0144 0.0044 E136804100027 56.51 -0.0392 0.0081 E136804100028 61.60 0.0103 0.0063 E136804100029 66.68 0.0095 0.0043 E136804100030 71.74 -0.0081 0.0031 E136804100031 76.79 -0.0302 0.0044 E136804100032 81.82 -0.0470 0.0093 E136804100033 86.84 0.0085 0.0117 E136804100034 91.85 0.0056 0.0076 E136804100035 96.84 -0.0091 0.0070 E136804100036 101.82 -0.0323 0.0085 E136804100037 106.79 -0.0022 0.0124 E136804100038 111.74 0.0477 0.0300 E136804100039 116.68 0.0221 0.0218 E136804100040 121.60 -0.0258 0.0198 E136804100041 126.51 0.0025 0.0194 E136804100042 131.42 0.0370 0.0206 E136804100043 136.31 0.0911 0.0159 E136804100044 141.19 0.2342 0.0172 E136804100045 146.06 0.1783 0.0218 E136804100046 150.92 0.1191 0.0250 E136804100047 155.78 0.0048 0.0233 E136804100048 160.63 0.0446 0.0187 E136804100049 165.48 0.1436 0.0147 E136804100050 170.32 0.1962 0.0140 E136804100051 ENDDATA 30 0 E136804100052 ENDSUBENT 51 0 E136804199999 SUBENT E1368042 20080131 E051E136804200001 BIB 7 12 E136804200002 REACTION (28-NI-64(D,EL)28-NI-64,21,POL/DA,,TAP) E136804200003 EN-SEC ANG is polar angle between beam and deuteron in E136804200004 laboratory system E136804200005 SAMPLE - Target enrichment is 96.48%. E136804200006 - Target-thickness is 0.82 mg/cm**2. E136804200007 METHOD (EDE) E136804200008 DETECTOR Solid angle of detector is 1.83 msr. E136804200009 (TELES) To detect scattered deuteron E136804200010 ERR-ANALYS (ERR-T) Total uncertainty E136804200011 (ERR-1) Uncertainty due to measured beam polarizations E136804200012 STATUS (TABLE) Data (Fig.1, p46 in main reference) taken from E136804200013 doctor thesis of M.Takei E136804200014 ENDBIB 12 0 E136804200015 COMMON 4 3 E136804200016 EN E-RSL ANG-ERR ERR-1 E136804200017 MEV KEV ADEG PER-CENT E136804200018 22. 90. 1.3 2. E136804200019 ENDCOMMON 3 0 E136804200020 DATA 3 29 E136804200021 ANG-CM DATA ERR-T E136804200022 ADEG NO-DIM NO-DIM E136804200023 30.90 -0.0156 0.0020 E136804200024 36.03 -0.0051 0.0020 E136804200025 41.15 -0.0001 0.0023 E136804200026 46.27 -0.0113 0.0029 E136804200027 51.37 -0.0165 0.0073 E136804200028 56.47 -0.0460 0.0098 E136804200029 61.55 0.0021 0.0075 E136804200030 66.62 0.0123 0.0055 E136804200031 71.68 -0.0138 0.0043 E136804200032 76.73 -0.0185 0.0073 E136804200033 81.76 -0.0145 0.0150 E136804200034 86.78 -0.0062 0.0097 E136804200035 91.79 -0.0059 0.0073 E136804200036 96.78 -0.0251 0.0099 E136804200037 101.76 -0.0155 0.0129 E136804200038 106.73 0.0006 0.0144 E136804200039 111.68 0.0396 0.0190 E136804200040 116.62 -0.0068 0.0230 E136804200041 121.55 -0.0162 0.0201 E136804200042 126.47 0.0027 0.0192 E136804200043 131.37 0.0497 0.0232 E136804200044 136.27 0.1332 0.0171 E136804200045 141.15 0.1508 0.0259 E136804200046 146.03 0.1611 0.0221 E136804200047 150.90 0.0317 0.0268 E136804200048 155.76 -0.0114 0.0247 E136804200049 160.61 0.0591 0.0196 E136804200050 165.46 0.1725 0.0165 E136804200051 170.31 0.2320 0.0153 E136804200052 ENDDATA 31 0 E136804200053 ENDSUBENT 52 0 E136804299999 SUBENT E1368043 20080131 E051E136804300001 BIB 7 12 E136804300002 REACTION (40-ZR-90(D,EL)40-ZR-90,21,POL/DA,,TAP) E136804300003 EN-SEC ANG is polar angle between beam and deuteron in E136804300004 laboratory system E136804300005 SAMPLE - Target enrichment is 97.62%. E136804300006 - Target-thickness is 1.00 mg/cm**2. E136804300007 METHOD (EDE) E136804300008 DETECTOR Solid angle of detector is 1.83 msr. E136804300009 (TELES) To detect scattered deuteron E136804300010 ERR-ANALYS (ERR-T) Total uncertainty E136804300011 (ERR-1) Uncertainty due to measured beam polarizations E136804300012 STATUS (TABLE) Data (Fig.1, p46 in main reference) taken from E136804300013 doctor thesis of M.Takei E136804300014 ENDBIB 12 0 E136804300015 COMMON 4 3 E136804300016 EN E-RSL ANG-ERR ERR-1 E136804300017 MEV KEV ADEG PER-CENT E136804300018 22. 90. 1.3 2. E136804300019 ENDCOMMON 3 0 E136804300020 DATA 3 23 E136804300021 ANG-CM DATA ERR-T E136804300022 ADEG NO-DIM NO-DIM E136804300023 61.10 -0.0267 0.0092 E136804300024 66.15 -0.0406 0.0136 E136804300025 71.20 -0.0216 0.0100 E136804300026 76.23 0.0160 0.0092 E136804300027 81.25 0.0166 0.0086 E136804300028 86.27 -0.0162 0.0103 E136804300029 91.27 -0.0240 0.0144 E136804300030 96.27 -0.0014 0.0109 E136804300031 101.25 0.0150 0.0083 E136804300032 106.23 0.0218 0.0071 E136804300033 111.20 0.0128 0.0077 E136804300034 116.15 -0.0012 0.0096 E136804300035 121.10 0.0212 0.0109 E136804300036 126.04 -0.0023 0.0160 E136804300037 130.98 -0.0159 0.0102 E136804300038 135.90 0.0296 0.0092 E136804300039 140.82 0.0702 0.0100 E136804300040 145.73 0.1707 0.0117 E136804300041 150.64 0.2111 0.0130 E136804300042 155.54 0.0398 0.0131 E136804300043 160.44 -0.0405 0.0127 E136804300044 165.33 0.0627 0.0095 E136804300045 170.22 0.1254 0.0088 E136804300046 ENDDATA 25 0 E136804300047 ENDSUBENT 46 0 E136804399999 SUBENT E1368044 20080131 E051E136804400001 BIB 7 12 E136804400002 REACTION (42-MO-92(D,EL)42-MO-92,21,POL/DA,,TAP) E136804400003 EN-SEC ANG is polar angle between beam and deuteron in E136804400004 laboratory system E136804400005 SAMPLE - Target enrichment is 95.13%. E136804400006 - Target-thickness is 1.62 mg/cm**2. E136804400007 METHOD (EDE) E136804400008 DETECTOR Solid angle of detector is 1.83 msr. E136804400009 (TELES) To detect scattered deuteron E136804400010 ERR-ANALYS (ERR-T) Total uncertainty E136804400011 (ERR-1) Uncertainty due to measured beam polarizations E136804400012 STATUS (TABLE) Data (Fig.1, p46 in main reference) taken from E136804400013 doctor thesis of M.Takei E136804400014 ENDBIB 12 0 E136804400015 COMMON 4 3 E136804400016 EN E-RSL ANG-ERR ERR-1 E136804400017 MEV KEV ADEG PER-CENT E136804400018 22. 90. 1.3 2. E136804400019 ENDCOMMON 3 0 E136804400020 DATA 3 29 E136804400021 ANG-CM DATA ERR-T E136804400022 ADEG NO-DIM NO-DIM E136804400023 30.62 -0.0033 0.0012 E136804400024 35.71 -0.0153 0.0020 E136804400025 40.80 -0.0269 0.0027 E136804400026 45.88 -0.0103 0.0027 E136804400027 50.95 -0.0214 0.0044 E136804400028 56.02 -0.0138 0.0059 E136804400029 61.08 -0.0243 0.0060 E136804400030 66.13 -0.0076 0.0095 E136804400031 71.17 -0.0015 0.0062 E136804400032 76.20 0.0162 0.0059 E136804400033 81.23 0.0071 0.0057 E136804400034 86.24 -0.0144 0.0044 E136804400035 91.25 -0.0200 0.0070 E136804400036 96.24 0.0062 0.0179 E136804400037 101.23 0.0296 0.0143 E136804400038 106.20 0.0182 0.0078 E136804400039 111.17 0.0180 0.0068 E136804400040 116.13 0.0290 0.0157 E136804400041 121.08 0.0036 0.0238 E136804400042 126.02 -0.0126 0.0270 E136804400043 130.95 -0.0060 0.0139 E136804400044 135.88 0.0342 0.0113 E136804400045 140.80 0.0733 0.0126 E136804400046 145.71 0.1637 0.0151 E136804400047 150.62 0.1638 0.0188 E136804400048 155.53 0.0681 0.0251 E136804400049 160.43 -0.0548 0.0222 E136804400050 165.32 0.0351 0.0173 E136804400051 170.22 0.0981 0.0154 E136804400052 ENDDATA 31 0 E136804400053 ENDSUBENT 52 0 E136804499999 SUBENT E1368045 20080131 E051E136804500001 BIB 7 12 E136804500002 REACTION (42-MO-100(D,EL)42-MO-100,21,POL/DA,,TAP) E136804500003 EN-SEC ANG is polar angle between beam and deuteron in E136804500004 laboratory system E136804500005 SAMPLE - Target enrichment is 97.27%. E136804500006 - Target-thickness is 1.52 mg/cm**2. E136804500007 METHOD (EDE) E136804500008 DETECTOR Solid angle of detector is 1.83 msr. E136804500009 (TELES) To detect scattered deuteron E136804500010 ERR-ANALYS (ERR-T) Total uncertainty E136804500011 (ERR-1) Uncertainty due to measured beam polarizations E136804500012 STATUS (TABLE) Data (Fig.1, p46 in main reference) taken from E136804500013 doctor thesis of M.Takei E136804500014 ENDBIB 12 0 E136804500015 COMMON 4 3 E136804500016 EN E-RSL ANG-ERR ERR-1 E136804500017 MEV KEV ADEG PER-CENT E136804500018 22. 90. 1.3 2. E136804500019 ENDCOMMON 3 0 E136804500020 DATA 3 29 E136804500021 ANG-CM DATA ERR-T E136804500022 ADEG NO-DIM NO-DIM E136804500023 30.57 -0.0066 0.0013 E136804500024 35.66 0.0023 0.0025 E136804500025 40.74 -0.0175 0.0026 E136804500026 45.81 -0.0154 0.0027 E136804500027 50.88 -0.0218 0.0052 E136804500028 55.94 -0.0077 0.0081 E136804500029 60.99 -0.0161 0.0087 E136804500030 66.04 -0.0334 0.0097 E136804500031 71.08 -0.0261 0.0055 E136804500032 76.11 -0.0138 0.0062 E136804500033 81.13 -0.0219 0.0072 E136804500034 86.14 -0.0306 0.0080 E136804500035 91.15 -0.0375 0.0118 E136804500036 96.14 0.0056 0.0166 E136804500037 101.13 0.0166 0.0147 E136804500038 106.11 -0.0141 0.0127 E136804500039 111.08 -0.0447 0.0179 E136804500040 116.04 -0.0850 0.0326 E136804500041 120.99 -0.0065 0.0329 E136804500042 125.94 -0.0072 0.0272 E136804500043 130.88 0.0175 0.0179 E136804500044 135.81 0.0228 0.0216 E136804500045 140.74 0.0254 0.0288 E136804500046 145.66 0.0286 0.0381 E136804500047 150.57 -0.0787 0.0439 E136804500048 155.48 -0.0305 0.0358 E136804500049 160.39 0.0769 0.0318 E136804500050 165.30 0.1313 0.0341 E136804500051 170.20 0.2083 0.0333 E136804500052 ENDDATA 31 0 E136804500053 ENDSUBENT 52 0 E136804599999 SUBENT E1368046 20080131 E051E136804600001 BIB 7 13 E136804600002 REACTION (46-PD-104(D,EL)46-PD-104,21,POL/DA,,TAP) E136804600003 EN-SEC ANG is polar angle between beam and deuteron in E136804600004 laboratory system E136804600005 SAMPLE - Target enrichment is 95.25%. E136804600006 - Target-thickness is 3.25 mg/cm**2. E136804600007 METHOD (EDE) E136804600008 DETECTOR Solid angle of detector is 2 msr. E136804600009 (MAGSP,SWPC) To momentum analyze and detect scattered E136804600010 deuteron E136804600011 ERR-ANALYS (ERR-T) Total uncertainty E136804600012 (ERR-1) Uncertainty due to measured beam polarizations E136804600013 STATUS (TABLE) Data (Fig.1, p46 in main reference) taken from E136804600014 doctor thesis of M.Takei E136804600015 ENDBIB 13 0 E136804600016 COMMON 3 3 E136804600017 EN ANG-ERR ERR-1 E136804600018 MEV ADEG PER-CENT E136804600019 21. 1.5 2. E136804600020 ENDCOMMON 3 0 E136804600021 DATA 3 27 E136804600022 ANG-CM DATA ERR-T E136804600023 ADEG NO-DIM NO-DIM E136804600024 40.71 -0.0002 0.0033 E136804600025 45.78 -0.0053 0.0036 E136804600026 50.84 -0.0094 0.0027 E136804600027 55.90 -0.0274 0.0043 E136804600028 60.95 -0.0331 0.0051 E136804600029 66.00 -0.0126 0.0053 E136804600030 71.04 -0.0156 0.0058 E136804600031 76.06 -0.0139 0.0068 E136804600032 81.09 -0.0390 0.0089 E136804600033 86.10 -0.0256 0.0092 E136804600034 91.10 -0.0128 0.0115 E136804600035 96.10 0.0174 0.0108 E136804600036 101.09 0.0103 0.0093 E136804600037 106.06 -0.0204 0.0100 E136804600038 111.04 -0.0486 0.0122 E136804600039 116.00 -0.0459 0.0166 E136804600040 120.95 -0.0290 0.0238 E136804600041 125.90 0.0141 0.0156 E136804600042 130.84 0.0366 0.0146 E136804600043 135.78 0.0361 0.0100 E136804600044 140.71 0.0278 0.0200 E136804600045 145.63 -0.0102 0.0263 E136804600046 150.55 -0.0365 0.0128 E136804600047 155.47 -0.0168 0.0310 E136804600048 160.38 0.0202 0.0107 E136804600049 165.29 0.0726 0.0103 E136804600050 170.19 0.1024 0.0107 E136804600051 ENDDATA 29 0 E136804600052 ENDSUBENT 51 0 E136804699999 SUBENT E1368047 20080131 E051E136804700001 BIB 7 13 E136804700002 REACTION (46-PD-106(D,EL)46-PD-106,21,POL/DA,,TAP) E136804700003 EN-SEC ANG is polar angle between beam and deuteron in E136804700004 laboratory system E136804700005 SAMPLE - Target enrichment is 96.66%. E136804700006 - Target-thickness is 3.42 mg/cm**2. E136804700007 METHOD (EDE) E136804700008 DETECTOR Solid angle of detector is 2 msr. E136804700009 (MAGSP,SWPC) To momentum analyze and detect scattered E136804700010 deuteron E136804700011 ERR-ANALYS (ERR-T) Total uncertainty E136804700012 (ERR-1) Uncertainty due to measured beam polarizations E136804700013 STATUS (TABLE) Data (Fig.1, p46 in main reference) taken from E136804700014 doctor thesis of M.Takei E136804700015 ENDBIB 13 0 E136804700016 COMMON 3 3 E136804700017 EN ANG-ERR ERR-1 E136804700018 MEV ADEG PER-CENT E136804700019 21. 1.5 2. E136804700020 ENDCOMMON 3 0 E136804700021 DATA 3 27 E136804700022 ANG-CM DATA ERR-T E136804700023 ADEG NO-DIM NO-DIM E136804700024 40.69 -0.0082 0.0038 E136804700025 45.76 -0.0044 0.0018 E136804700026 50.83 -0.0182 0.0024 E136804700027 55.89 -0.0285 0.0038 E136804700028 60.94 -0.0238 0.0046 E136804700029 65.98 -0.0111 0.0047 E136804700030 71.02 -0.0153 0.0053 E136804700031 76.04 -0.0242 0.0066 E136804700032 81.06 -0.0193 0.0085 E136804700033 86.08 -0.0305 0.0085 E136804700034 91.08 -0.0026 0.0100 E136804700035 96.08 0.0194 0.0100 E136804700036 101.06 -0.0020 0.0104 E136804700037 106.04 -0.0069 0.0107 E136804700038 111.02 -0.0532 0.0124 E136804700039 115.98 -0.0185 0.0161 E136804700040 120.94 -0.0029 0.0168 E136804700041 125.89 0.0405 0.0152 E136804700042 130.83 0.0445 0.0151 E136804700043 135.76 0.0165 0.0172 E136804700044 140.69 0.0097 0.0122 E136804700045 145.62 -0.0034 0.0132 E136804700046 150.54 -0.0282 0.0137 E136804700047 155.46 0.0098 0.0122 E136804700048 160.37 0.0356 0.0114 E136804700049 165.28 0.0859 0.0110 E136804700050 170.19 0.0942 0.0122 E136804700051 ENDDATA 29 0 E136804700052 ENDSUBENT 51 0 E136804799999 SUBENT E1368048 20080131 E051E136804800001 BIB 7 13 E136804800002 REACTION (46-PD-108(D,EL)46-PD-108,21,POL/DA,,TAP) E136804800003 EN-SEC ANG is polar angle between beam and deuteron in E136804800004 laboratory system E136804800005 SAMPLE - Target enrichment is 98.11%. E136804800006 - Target-thickness is 3.26 mg/cm**2. E136804800007 METHOD (EDE) E136804800008 DETECTOR Solid angle of detector is 2 msr. E136804800009 (MAGSP,SWPC) To momentum analyze and detect scattered E136804800010 deuteron E136804800011 ERR-ANALYS (ERR-T) Total uncertainty E136804800012 (ERR-1) Uncertainty due to measured beam polarizations E136804800013 STATUS (TABLE) Data (Fig.1, p46 in main reference) taken from E136804800014 doctor thesis of M.Takei E136804800015 ENDBIB 13 0 E136804800016 COMMON 3 3 E136804800017 EN ANG-ERR ERR-1 E136804800018 MEV ADEG PER-CENT E136804800019 21. 1.5 2. E136804800020 ENDCOMMON 3 0 E136804800021 DATA 3 22 E136804800022 ANG-CM DATA ERR-T E136804800023 ADEG NO-DIM NO-DIM E136804800024 71.00 -0.0152 0.0033 E136804800025 76.02 -0.0268 0.0042 E136804800026 81.04 -0.0346 0.0055 E136804800027 86.06 -0.0384 0.0070 E136804800028 91.06 -0.0234 0.0085 E136804800029 96.06 -0.0022 0.0091 E136804800030 101.04 -0.0101 0.0096 E136804800031 106.02 -0.0106 0.0092 E136804800032 111.00 -0.0504 0.0124 E136804800033 115.96 -0.0570 0.0132 E136804800034 120.92 -0.0264 0.0125 E136804800035 123.39 0.0147 0.0121 E136804800036 125.87 0.0209 0.0111 E136804800037 130.81 0.0267 0.0114 E136804800038 135.75 0.0273 0.0116 E136804800039 140.68 -0.0095 0.0156 E136804800040 145.61 -0.0314 0.0136 E136804800041 150.53 -0.0225 0.0131 E136804800042 155.45 0.0115 0.0120 E136804800043 160.36 0.0462 0.0115 E136804800044 165.27 0.0489 0.0127 E136804800045 170.18 0.0531 0.0143 E136804800046 ENDDATA 24 0 E136804800047 ENDSUBENT 46 0 E136804899999 SUBENT E1368049 20080131 E051E136804900001 BIB 7 13 E136804900002 REACTION (46-PD-110(D,EL)46-PD-110,21,POL/DA,,TAP) E136804900003 EN-SEC ANG is polar angle between beam and deuteron in E136804900004 laboratory system E136804900005 SAMPLE - Target enrichment is 97.73%. E136804900006 - Target-thickness is 2.26 mg/cm**2. E136804900007 METHOD (EDE) E136804900008 DETECTOR Solid angle of detector is 2 msr. E136804900009 (MAGSP,SWPC) To momentum analyze and detect scattered E136804900010 deuteron E136804900011 ERR-ANALYS (ERR-T) Total uncertainty E136804900012 (ERR-1) Uncertainty due to measured beam polarizations E136804900013 STATUS (TABLE) Data (Fig.1, p46 in main reference) taken from E136804900014 doctor thesis of M.Takei E136804900015 ENDBIB 13 0 E136804900016 COMMON 3 3 E136804900017 EN ANG-ERR ERR-1 E136804900018 MEV ADEG PER-CENT E136804900019 21. 1.5 2. E136804900020 ENDCOMMON 3 0 E136804900021 DATA 3 23 E136804900022 ANG-CM DATA ERR-T E136804900023 ADEG NO-DIM NO-DIM E136804900024 60.90 -0.0229 0.0047 E136804900025 65.94 -0.0204 0.0050 E136804900026 70.98 -0.0280 0.0050 E136804900027 76.01 -0.0329 0.0066 E136804900028 81.03 -0.0241 0.0060 E136804900029 86.04 -0.0224 0.0075 E136804900030 91.04 -0.0193 0.0073 E136804900031 96.04 -0.0103 0.0087 E136804900032 101.03 -0.0153 0.0105 E136804900033 106.01 -0.0546 0.0115 E136804900034 110.98 -0.0559 0.0114 E136804900035 115.94 -0.0267 0.0139 E136804900036 120.90 -0.0240 0.0140 E136804900037 125.85 0.0101 0.0136 E136804900038 130.80 0.0210 0.0143 E136804900039 135.74 -0.0167 0.0144 E136804900040 140.67 -0.0183 0.0155 E136804900041 145.60 -0.0435 0.0161 E136804900042 150.52 -0.0217 0.0159 E136804900043 155.44 -0.0043 0.0154 E136804900044 160.36 0.0377 0.0149 E136804900045 165.27 0.0217 0.0163 E136804900046 170.18 -0.0002 0.0185 E136804900047 ENDDATA 25 0 E136804900048 ENDSUBENT 47 0 E136804999999 SUBENT E1368050 20080131 E051E136805000001 BIB 7 14 E136805000002 REACTION (20-CA-40(D,EL)20-CA-40,22,POL/DA,,TAP) E136805000003 EN-SEC ANG is polar angle between beam and deuteron in E136805000004 laboratory system E136805000005 SAMPLE - Target is natural. E136805000006 - Target-thickness is 0.51 mg/cm**2. E136805000007 - Backing is mylar film. E136805000008 - Backing-thickness: 1-micro meter E136805000009 METHOD (EDE) E136805000010 DETECTOR Solid angle of detector is 1.83 msr. E136805000011 (TELES) To detect scattered deuteron E136805000012 ERR-ANALYS (ERR-T) Total uncertainty E136805000013 (ERR-1) Uncertainty due to measured beam polarizations E136805000014 STATUS (TABLE) Data (Fig.1, p47 in main reference) taken from E136805000015 doctor thesis of M.Takei E136805000016 ENDBIB 14 0 E136805000017 COMMON 4 3 E136805000018 EN E-RSL ANG-ERR ERR-1 E136805000019 MEV KEV ADEG PER-CENT E136805000020 22. 90. 1.3 2. E136805000021 ENDCOMMON 3 0 E136805000022 DATA 3 24 E136805000023 ANG-CM DATA ERR-T E136805000024 ADEG NO-DIM NO-DIM E136805000025 57.35 0.0290 0.0071 E136805000026 62.48 -0.0190 0.0097 E136805000027 67.60 -0.1256 0.0113 E136805000028 72.69 -0.2062 0.0132 E136805000029 77.77 -0.0023 0.0093 E136805000030 82.82 0.0827 0.0074 E136805000031 87.86 0.1259 0.0055 E136805000032 92.87 0.0989 0.0060 E136805000033 97.86 0.0137 0.0099 E136805000034 102.82 -0.0956 0.0117 E136805000035 107.77 -0.1500 0.0089 E136805000036 112.69 -0.0879 0.0091 E136805000037 117.60 -0.0263 0.0105 E136805000038 122.48 0.0568 0.0104 E136805000039 127.35 0.1271 0.0105 E136805000040 132.20 0.1217 0.0111 E136805000041 137.03 -0.0081 0.0126 E136805000042 141.84 -0.1507 0.0140 E136805000043 146.64 -0.1314 0.0168 E136805000044 151.43 0.2367 0.0137 E136805000045 156.21 0.1367 0.0144 E136805000046 160.98 -0.0258 0.0129 E136805000047 165.74 -0.1947 0.0122 E136805000048 170.50 -0.2360 0.0127 E136805000049 ENDDATA 26 0 E136805000050 ENDSUBENT 49 0 E136805099999 SUBENT E1368051 20080131 E051E136805100001 BIB 7 12 E136805100002 REACTION (28-NI-58(D,EL)28-NI-58,22,POL/DA,,TAP) E136805100003 EN-SEC ANG is polar angle between beam and deuteron in E136805100004 laboratory system E136805100005 SAMPLE - Target enrichment is 99.89%. E136805100006 - Target-thickness is 0.98 mg/cm**2. E136805100007 METHOD (EDE) E136805100008 DETECTOR Solid angle of detector is 1.83 msr. E136805100009 (TELES) To detect scattered deuteron E136805100010 ERR-ANALYS (ERR-T) Total uncertainty E136805100011 (ERR-1) Uncertainty due to measured beam polarizations E136805100012 STATUS (TABLE) Data (Fig.1, p47 in main reference) taken from E136805100013 doctor thesis of M.Takei E136805100014 ENDBIB 12 0 E136805100015 COMMON 4 3 E136805100016 EN E-RSL ANG-ERR ERR-1 E136805100017 MEV KEV ADEG PER-CENT E136805100018 22. 90. 1.3 2. E136805100019 ENDCOMMON 3 0 E136805100020 DATA 3 29 E136805100021 ANG-CM DATA ERR-T E136805100022 ADEG NO-DIM NO-DIM E136805100023 30.99 -0.0128 0.0025 E136805100024 36.13 -0.0144 0.0025 E136805100025 41.27 -0.0031 0.0023 E136805100026 46.40 -0.0067 0.0026 E136805100027 51.51 -0.0139 0.0069 E136805100028 56.62 -0.0804 0.0081 E136805100029 61.71 -0.1542 0.0119 E136805100030 66.79 0.0094 0.0076 E136805100031 71.86 -0.0141 0.0039 E136805100032 76.91 -0.0283 0.0047 E136805100033 81.95 -0.0911 0.0079 E136805100034 86.97 -0.3118 0.0190 E136805100035 91.98 -0.0005 0.0143 E136805100036 96.97 0.0438 0.0105 E136805100037 101.95 0.0454 0.0100 E136805100038 106.91 0.0108 0.0122 E136805100039 111.86 -0.1057 0.0210 E136805100040 116.79 -0.2459 0.0312 E136805100041 121.71 -0.2788 0.0311 E136805100042 126.62 0.0474 0.0264 E136805100043 131.51 0.2699 0.0186 E136805100044 136.40 0.1853 0.0185 E136805100045 141.27 0.0856 0.0201 E136805100046 146.13 -0.2044 0.0251 E136805100047 150.99 -0.2840 0.0315 E136805100048 155.84 -0.0584 0.0330 E136805100049 160.68 -0.1208 0.0253 E136805100050 165.51 -0.1804 0.0209 E136805100051 170.34 -0.1571 0.0220 E136805100052 ENDDATA 31 0 E136805100053 ENDSUBENT 52 0 E136805199999 SUBENT E1368052 20080131 E051E136805200001 BIB 7 12 E136805200002 REACTION (28-NI-60(D,EL)28-NI-60,22,POL/DA,,TAP) E136805200003 EN-SEC ANG is polar angle between beam and deuteron in E136805200004 laboratory system E136805200005 SAMPLE - Target enrichment is 99.79%. E136805200006 - Target-thickness is 0.95 mg/cm**2. E136805200007 METHOD (EDE) E136805200008 DETECTOR Solid angle of detector is 1.83 msr. E136805200009 (TELES) To detect scattered deuteron E136805200010 ERR-ANALYS (ERR-T) Total uncertainty E136805200011 (ERR-1) Uncertainty due to measured beam polarizations E136805200012 STATUS (TABLE) Data (Fig.1, p47 in main reference) taken from E136805200013 doctor thesis of M.Takei E136805200014 ENDBIB 12 0 E136805200015 COMMON 4 3 E136805200016 EN E-RSL ANG-ERR ERR-1 E136805200017 MEV KEV ADEG PER-CENT E136805200018 22. 90. 1.3 2. E136805200019 ENDCOMMON 3 0 E136805200020 DATA 3 28 E136805200021 ANG-CM DATA ERR-T E136805200022 ADEG NO-DIM NO-DIM E136805200023 36.10 -0.0228 0.0022 E136805200024 41.23 -0.0080 0.0020 E136805200025 46.35 -0.0095 0.0023 E136805200026 51.46 -0.0542 0.0049 E136805200027 56.56 -0.0925 0.0085 E136805200028 61.65 -0.0696 0.0089 E136805200029 66.73 0.0211 0.0055 E136805200030 71.79 -0.0132 0.0035 E136805200031 76.85 -0.0571 0.0048 E136805200032 81.88 -0.1825 0.0100 E136805200033 86.90 -0.2583 0.0183 E136805200034 91.91 0.0636 0.0104 E136805200035 96.90 0.0922 0.0088 E136805200036 101.88 0.0361 0.0096 E136805200037 106.85 -0.0486 0.0132 E136805200038 111.80 -0.2785 0.0269 E136805200039 116.73 -0.2670 0.0316 E136805200040 121.65 0.0270 0.0273 E136805200041 126.56 0.1243 0.0237 E136805200042 131.46 0.1688 0.0232 E136805200043 136.35 0.1480 0.0181 E136805200044 141.23 -0.0800 0.0209 E136805200045 146.10 -0.2914 0.0279 E136805200046 150.96 -0.2219 0.0339 E136805200047 155.81 0.2568 0.0293 E136805200048 160.65 0.1643 0.0223 E136805200049 165.49 -0.0340 0.0195 E136805200050 170.33 -0.1328 0.0197 E136805200051 ENDDATA 30 0 E136805200052 ENDSUBENT 51 0 E136805299999 SUBENT E1368053 20080131 E051E136805300001 BIB 7 12 E136805300002 REACTION (28-NI-62(D,EL)28-NI-62,22,POL/DA,,TAP) E136805300003 EN-SEC ANG is polar angle between beam and deuteron in E136805300004 laboratory system E136805300005 SAMPLE - Target enrichment is 98.70%. E136805300006 - Target-thickness is 1.12 mg/cm**2. E136805300007 METHOD (EDE) E136805300008 DETECTOR Solid angle of detector is 1.83 msr. E136805300009 (TELES) To detect scattered deuteron E136805300010 ERR-ANALYS (ERR-T) Total uncertainty E136805300011 (ERR-1) Uncertainty due to measured beam polarizations E136805300012 STATUS (TABLE) Data (Fig.1, p47 in main reference) taken from E136805300013 doctor thesis of M.Takei E136805300014 ENDBIB 12 0 E136805300015 COMMON 4 3 E136805300016 EN E-RSL ANG-ERR ERR-1 E136805300017 MEV KEV ADEG PER-CENT E136805300018 22. 90. 1.3 2. E136805300019 ENDCOMMON 3 0 E136805300020 DATA 3 28 E136805300021 ANG-CM DATA ERR-T E136805300022 ADEG NO-DIM NO-DIM E136805300023 36.06 -0.0186 0.0023 E136805300024 41.19 -0.0086 0.0021 E136805300025 46.31 -0.0221 0.0026 E136805300026 51.42 -0.0734 0.0058 E136805300027 56.51 -0.1169 0.0103 E136805300028 61.60 -0.0096 0.0077 E136805300029 66.68 0.0096 0.0053 E136805300030 71.74 -0.0334 0.0039 E136805300031 76.79 -0.0860 0.0059 E136805300032 81.82 -0.3209 0.0146 E136805300033 86.84 -0.0299 0.0143 E136805300034 91.85 0.1032 0.0095 E136805300035 96.84 0.0723 0.0086 E136805300036 101.82 0.0146 0.0100 E136805300037 106.79 -0.1515 0.0159 E136805300038 111.74 -0.2680 0.0391 E136805300039 116.68 -0.0429 0.0269 E136805300040 121.60 0.1191 0.0234 E136805300041 126.51 0.1655 0.0232 E136805300042 131.42 0.0942 0.0253 E136805300043 136.31 -0.0058 0.0201 E136805300044 141.19 -0.2381 0.0250 E136805300045 146.06 -0.3494 0.0314 E136805300046 150.92 0.0606 0.0316 E136805300047 155.78 0.4834 0.0279 E136805300048 160.63 0.2770 0.0230 E136805300049 165.48 0.0609 0.0189 E136805300050 170.32 -0.0633 0.0189 E136805300051 ENDDATA 30 0 E136805300052 ENDSUBENT 51 0 E136805399999 SUBENT E1368054 20080131 E051E136805400001 BIB 7 12 E136805400002 REACTION (28-NI-64(D,EL)28-NI-64,22,POL/DA,,TAP) E136805400003 EN-SEC ANG is polar angle between beam and deuteron in E136805400004 laboratory system E136805400005 SAMPLE - Target enrichment is 96.48%. E136805400006 - Target-thickness is 0.82 mg/cm**2. E136805400007 METHOD (EDE) E136805400008 DETECTOR Solid angle of detector is 1.83 msr. E136805400009 (TELES) To detect scattered deuteron E136805400010 ERR-ANALYS (ERR-T) Total uncertainty E136805400011 (ERR-1) Uncertainty due to measured beam polarizations E136805400012 STATUS (TABLE) Data (Fig.1, p47 in main reference) taken from E136805400013 doctor thesis of M.Takei E136805400014 ENDBIB 12 0 E136805400015 COMMON 4 3 E136805400016 EN E-RSL ANG-ERR ERR-1 E136805400017 MEV KEV ADEG PER-CENT E136805400018 22. 90. 1.3 2. E136805400019 ENDCOMMON 3 0 E136805400020 DATA 3 29 E136805400021 ANG-CM DATA ERR-T E136805400022 ADEG NO-DIM NO-DIM E136805400023 30.90 -0.0093 0.0024 E136805400024 36.03 -0.0137 0.0025 E136805400025 41.15 -0.0071 0.0027 E136805400026 46.27 -0.0131 0.0035 E136805400027 51.37 -0.0642 0.0089 E136805400028 56.47 -0.1191 0.0124 E136805400029 61.55 -0.0077 0.0091 E136805400030 66.62 -0.0073 0.0068 E136805400031 71.68 -0.0530 0.0055 E136805400032 76.73 -0.1459 0.0099 E136805400033 81.76 -0.3477 0.0212 E136805400034 86.78 0.0375 0.0117 E136805400035 91.79 0.0858 0.0089 E136805400036 96.78 0.0609 0.0118 E136805400037 101.76 -0.0226 0.0156 E136805400038 106.73 -0.2358 0.0190 E136805400039 111.68 -0.2580 0.0253 E136805400040 116.62 0.0407 0.0277 E136805400041 121.55 0.1258 0.0239 E136805400042 126.47 0.0748 0.0231 E136805400043 131.37 0.0044 0.0287 E136805400044 136.27 -0.1272 0.0226 E136805400045 141.15 -0.2667 0.0355 E136805400046 146.03 -0.2187 0.0302 E136805400047 150.90 0.0504 0.0326 E136805400048 155.76 0.4491 0.0293 E136805400049 160.61 0.2674 0.0242 E136805400050 165.46 0.0046 0.0215 E136805400051 170.31 -0.0543 0.0208 E136805400052 ENDDATA 31 0 E136805400053 ENDSUBENT 52 0 E136805499999 SUBENT E1368055 20080131 E051E136805500001 BIB 7 12 E136805500002 REACTION (40-ZR-90(D,EL)40-ZR-90,22,POL/DA,,TAP) E136805500003 EN-SEC ANG is polar angle between beam and deuteron in E136805500004 laboratory system E136805500005 SAMPLE - Target enrichment is 97.62%. E136805500006 - Target-thickness is 1.00 mg/cm**2. E136805500007 METHOD (EDE) E136805500008 DETECTOR Solid angle of detector is 1.83 msr. E136805500009 (TELES) To detect scattered deuteron E136805500010 ERR-ANALYS (ERR-T) Total uncertainty E136805500011 (ERR-1) Uncertainty due to measured beam polarizations E136805500012 STATUS (TABLE) Data (Fig.1, p47 in main reference) taken from E136805500013 doctor thesis of M.Takei E136805500014 ENDBIB 12 0 E136805500015 COMMON 4 3 E136805500016 EN E-RSL ANG-ERR ERR-1 E136805500017 MEV KEV ADEG PER-CENT E136805500018 22. 90. 1.3 2. E136805500019 ENDCOMMON 3 0 E136805500020 DATA 3 23 E136805500021 ANG-CM DATA ERR-T E136805500022 ADEG NO-DIM NO-DIM E136805500023 61.10 -0.0623 0.0113 E136805500024 66.15 -0.1496 0.0166 E136805500025 71.20 -0.0665 0.0124 E136805500026 76.23 0.0304 0.0113 E136805500027 81.25 0.0111 0.0106 E136805500028 86.27 -0.0676 0.0127 E136805500029 91.27 -0.2576 0.0142 E136805500030 96.27 -0.2173 0.0137 E136805500031 101.25 0.0957 0.0100 E136805500032 106.23 0.0588 0.0088 E136805500033 111.20 -0.0510 0.0097 E136805500034 116.15 -0.2501 0.0122 E136805500035 121.10 -0.3241 0.0140 E136805500036 126.04 -0.0110 0.0142 E136805500037 130.98 0.1011 0.0121 E136805500038 135.90 0.0871 0.0113 E136805500039 140.82 -0.0829 0.0127 E136805500040 145.73 -0.2167 0.0149 E136805500041 150.64 -0.3232 0.0167 E136805500042 155.54 0.1083 0.0161 E136805500043 160.44 0.2866 0.0141 E136805500044 165.33 0.0497 0.0119 E136805500045 170.22 -0.0397 0.0108 E136805500046 ENDDATA 25 0 E136805500047 ENDSUBENT 46 0 E136805599999 SUBENT E1368056 20080131 E051E136805600001 BIB 7 12 E136805600002 REACTION (42-MO-92(D,EL)42-MO-92,22,POL/DA,,TAP) E136805600003 EN-SEC ANG is polar angle between beam and deuteron in E136805600004 laboratory system E136805600005 SAMPLE - Target enrichment is 95.13%. E136805600006 - Target-thickness is 1.62 mg/cm**2. E136805600007 METHOD (EDE) E136805600008 DETECTOR Solid angle of detector is 1.83 msr. E136805600009 (TELES) To detect scattered deuteron E136805600010 ERR-ANALYS (ERR-T) Total uncertainty E136805600011 (ERR-1) Uncertainty due to measured beam polarizations E136805600012 STATUS (TABLE) Data (Fig.1, p47 in main reference) taken from E136805600013 doctor thesis of M.Takei E136805600014 ENDBIB 12 0 E136805600015 COMMON 4 3 E136805600016 EN E-RSL ANG-ERR ERR-1 E136805600017 MEV KEV ADEG PER-CENT E136805600018 22. 90. 1.3 2. E136805600019 ENDCOMMON 3 0 E136805600020 DATA 3 29 E136805600021 ANG-CM DATA ERR-T E136805600022 ADEG NO-DIM NO-DIM E136805600023 30.62 -0.0040 0.0013 E136805600024 35.71 -0.0322 0.0026 E136805600025 40.80 -0.0248 0.0035 E136805600026 45.88 -0.0185 0.0034 E136805600027 50.95 -0.0009 0.0053 E136805600028 56.02 0.0053 0.0071 E136805600029 61.08 -0.0422 0.0073 E136805600030 66.13 -0.1173 0.0122 E136805600031 71.17 -0.0729 0.0079 E136805600032 76.20 0.0378 0.0073 E136805600033 81.23 0.0146 0.0069 E136805600034 86.24 -0.0794 0.0059 E136805600035 91.25 -0.2261 0.0109 E136805600036 96.24 -0.1952 0.0231 E136805600037 101.23 0.0640 0.0175 E136805600038 106.20 0.0481 0.0096 E136805600039 111.17 -0.0660 0.0085 E136805600040 116.13 -0.1883 0.0205 E136805600041 121.08 -0.3681 0.0319 E136805600042 126.02 0.0416 0.0324 E136805600043 130.95 0.1415 0.0168 E136805600044 135.88 0.0292 0.0139 E136805600045 140.80 -0.1194 0.0164 E136805600046 145.71 -0.2775 0.0218 E136805600047 150.62 -0.2969 0.0268 E136805600048 155.53 0.1957 0.0306 E136805600049 160.43 0.3259 0.0263 E136805600050 165.32 0.1705 0.0212 E136805600051 170.22 -0.0273 0.0196 E136805600052 ENDDATA 31 0 E136805600053 ENDSUBENT 52 0 E136805699999 SUBENT E1368057 20080131 E051E136805700001 BIB 7 12 E136805700002 REACTION (42-MO-100(D,EL)42-MO-100,22,POL/DA,,TAP) E136805700003 EN-SEC ANG is polar angle between beam and deuteron in E136805700004 laboratory system E136805700005 SAMPLE - Target enrichment is 97.27%. E136805700006 - Target-thickness is 1.52 mg/cm**2. E136805700007 METHOD (EDE) E136805700008 DETECTOR Solid angle of detector is 1.83 msr. E136805700009 (TELES) To detect scattered deuteron E136805700010 ERR-ANALYS (ERR-T) Total uncertainty E136805700011 (ERR-1) Uncertainty due to measured beam polarizations E136805700012 STATUS (TABLE) Data (Fig.1, p47 in main reference) taken from E136805700013 doctor thesis of M.Takei E136805700014 ENDBIB 12 0 E136805700015 COMMON 4 3 E136805700016 EN E-RSL ANG-ERR ERR-1 E136805700017 MEV KEV ADEG PER-CENT E136805700018 22. 90. 1.3 2. E136805700019 ENDCOMMON 3 0 E136805700020 DATA 3 29 E136805700021 ANG-CM DATA ERR-T E136805700022 ADEG NO-DIM NO-DIM E136805700023 30.57 -0.0117 0.0017 E136805700024 35.66 -0.0373 0.0033 E136805700025 40.74 -0.0201 0.0032 E136805700026 45.81 -0.0273 0.0034 E136805700027 50.88 -0.0269 0.0064 E136805700028 55.94 -0.0244 0.0098 E136805700029 60.99 -0.0430 0.0107 E136805700030 66.04 -0.0365 0.0118 E136805700031 71.08 0.0017 0.0067 E136805700032 76.11 -0.0155 0.0075 E136805700033 81.13 -0.0593 0.0089 E136805700034 86.14 -0.1129 0.0103 E136805700035 91.15 -0.0607 0.0143 E136805700036 96.14 0.0758 0.0201 E136805700037 101.13 0.0248 0.0179 E136805700038 106.11 -0.0825 0.0158 E136805700039 111.08 -0.1932 0.0227 E136805700040 116.04 -0.1187 0.0392 E136805700041 120.99 0.1226 0.0391 E136805700042 125.94 0.1113 0.0324 E136805700043 130.88 -0.0215 0.0219 E136805700044 135.81 -0.1234 0.0271 E136805700045 140.74 -0.1409 0.0361 E136805700046 145.66 -0.0454 0.0471 E136805700047 150.57 0.1411 0.0507 E136805700048 155.48 0.0593 0.0425 E136805700049 160.39 0.0489 0.0394 E136805700050 165.30 -0.0791 0.0440 E136805700051 170.20 -0.0989 0.0446 E136805700052 ENDDATA 31 0 E136805700053 ENDSUBENT 52 0 E136805799999 SUBENT E1368058 20080131 E051E136805800001 BIB 7 13 E136805800002 REACTION (46-PD-104(D,EL)46-PD-104,22,POL/DA,,TAP) E136805800003 EN-SEC ANG is polar angle between beam and deuteron in E136805800004 laboratory system E136805800005 SAMPLE - Target enrichment is 95.25%. E136805800006 - Target-thickness is 3.25 mg/cm**2. E136805800007 METHOD (EDE) E136805800008 DETECTOR Solid angle of detector is 2 msr. E136805800009 (MAGSP,SWPC) To momentum analyze and detect scattered E136805800010 deuteron E136805800011 ERR-ANALYS (ERR-T) Total uncertainty E136805800012 (ERR-1) Uncertainty due to measured beam polarizations E136805800013 STATUS (TABLE) Data (Fig.1, p47 in main reference) taken from E136805800014 doctor thesis of M.Takei E136805800015 ENDBIB 13 0 E136805800016 COMMON 3 3 E136805800017 EN ANG-ERR ERR-1 E136805800018 MEV ADEG PER-CENT E136805800019 21. 1.5 2. E136805800020 ENDCOMMON 3 0 E136805800021 DATA 3 27 E136805800022 ANG-CM DATA ERR-T E136805800023 ADEG NO-DIM NO-DIM E136805800024 40.71 -0.0182 0.0038 E136805800025 45.78 -0.0001 0.0042 E136805800026 50.84 -0.0155 0.0019 E136805800027 55.90 -0.0254 0.0029 E136805800028 60.95 -0.0236 0.0033 E136805800029 66.00 -0.0115 0.0037 E136805800030 71.04 0.0029 0.0040 E136805800031 76.06 -0.0093 0.0042 E136805800032 81.09 -0.0376 0.0054 E136805800033 86.10 -0.0544 0.0066 E136805800034 91.10 -0.0078 0.0087 E136805800035 96.10 0.0216 0.0082 E136805800036 101.09 0.0104 0.0075 E136805800037 106.06 -0.0410 0.0078 E136805800038 111.04 -0.0963 0.0093 E136805800039 116.00 -0.0483 0.0129 E136805800040 120.95 0.0923 0.0160 E136805800041 125.90 0.0622 0.0146 E136805800042 130.84 -0.0272 0.0130 E136805800043 135.78 -0.0949 0.0128 E136805800044 140.71 -0.1324 0.0168 E136805800045 145.63 -0.0595 0.0230 E136805800046 150.55 0.0847 0.0151 E136805800047 155.47 0.1532 0.0281 E136805800048 160.38 0.0710 0.0129 E136805800049 165.29 -0.0158 0.0127 E136805800050 170.19 -0.0181 0.0137 E136805800051 ENDDATA 29 0 E136805800052 ENDSUBENT 51 0 E136805899999 SUBENT E1368059 20080131 E051E136805900001 BIB 7 13 E136805900002 REACTION (46-PD-106(D,EL)46-PD-106,22,POL/DA,,TAP) E136805900003 EN-SEC ANG is polar angle between beam and deuteron in E136805900004 laboratory system E136805900005 SAMPLE - Target enrichment is 96.66%. E136805900006 - Target-thickness is 3.42 mg/cm**2. E136805900007 METHOD (EDE) E136805900008 DETECTOR Solid angle of detector is 2 msr. E136805900009 (MAGSP,SWPC) To momentum analyze and detect scattered E136805900010 deuteron E136805900011 ERR-ANALYS (ERR-T) Total uncertainty E136805900012 (ERR-1) Uncertainty due to measured beam polarizations E136805900013 STATUS (TABLE) Data (Fig.1, p47 in main reference) taken from E136805900014 doctor thesis of M.Takei E136805900015 ENDBIB 13 0 E136805900016 COMMON 3 3 E136805900017 EN ANG-ERR ERR-1 E136805900018 MEV ADEG PER-CENT E136805900019 21. 1.5 2. E136805900020 ENDCOMMON 3 0 E136805900021 DATA 3 27 E136805900022 ANG-CM DATA ERR-T E136805900023 ADEG NO-DIM NO-DIM E136805900024 40.69 -0.0059 0.0044 E136805900025 45.76 -0.0078 0.0013 E136805900026 50.83 -0.0184 0.0018 E136805900027 55.89 -0.0282 0.0027 E136805900028 60.94 -0.0202 0.0031 E136805900029 65.98 -0.0119 0.0033 E136805900030 71.02 0.0023 0.0036 E136805900031 76.04 -0.0046 0.0040 E136805900032 81.06 -0.0380 0.0052 E136805900033 86.08 -0.0420 0.0061 E136805900034 91.08 0.0044 0.0077 E136805900035 96.08 0.0280 0.0072 E136805900036 101.06 -0.0030 0.0066 E136805900037 106.04 -0.0645 0.0070 E136805900038 111.02 -0.0966 0.0093 E136805900039 115.98 -0.0252 0.0124 E136805900040 120.94 0.0957 0.0141 E136805900041 125.89 0.0182 0.0135 E136805900042 130.83 -0.0613 0.0128 E136805900043 135.76 -0.1157 0.0139 E136805900044 140.69 -0.0990 0.0153 E136805900045 145.62 -0.0097 0.0157 E136805900046 150.54 0.1165 0.0163 E136805900047 155.46 0.0573 0.0147 E136805900048 160.37 -0.0265 0.0139 E136805900049 165.28 -0.0658 0.0141 E136805900050 170.19 -0.0691 0.0158 E136805900051 ENDDATA 29 0 E136805900052 ENDSUBENT 51 0 E136805999999 SUBENT E1368060 20080131 E051E136806000001 BIB 7 13 E136806000002 REACTION (46-PD-108(D,EL)46-PD-108,22,POL/DA,,TAP) E136806000003 EN-SEC ANG is polar angle between beam and deuteron in E136806000004 laboratory system E136806000005 SAMPLE - Target enrichment is 98.11%. E136806000006 - Target-thickness is 3.26 mg/cm**2. E136806000007 METHOD (EDE) E136806000008 DETECTOR Solid angle of detector is 2 msr. E136806000009 (MAGSP,SWPC) To momentum analyze and detect scattered E136806000010 deuteron E136806000011 ERR-ANALYS (ERR-T) Total uncertainty E136806000012 (ERR-1) Uncertainty due to measured beam polarizations E136806000013 STATUS (TABLE) Data (Fig.1, p47 in main reference) taken from E136806000014 doctor thesis of M.Takei E136806000015 ENDBIB 13 0 E136806000016 COMMON 3 3 E136806000017 EN ANG-ERR ERR-1 E136806000018 MEV ADEG PER-CENT E136806000019 21. 1.5 2. E136806000020 ENDCOMMON 3 0 E136806000021 DATA 3 22 E136806000022 ANG-CM DATA ERR-T E136806000023 ADEG NO-DIM NO-DIM E136806000024 71.00 0.0007 0.0039 E136806000025 76.02 -0.0114 0.0050 E136806000026 81.04 -0.0338 0.0066 E136806000027 86.06 -0.0354 0.0084 E136806000028 91.06 0.0163 0.0102 E136806000029 96.06 0.0192 0.0109 E136806000030 101.04 -0.0014 0.0116 E136806000031 106.02 -0.0552 0.0111 E136806000032 111.00 -0.0636 0.0151 E136806000033 115.96 0.0025 0.0157 E136806000034 120.92 0.0662 0.0154 E136806000035 123.39 0.0762 0.0147 E136806000036 125.87 0.0179 0.0137 E136806000037 130.81 -0.0369 0.0143 E136806000038 135.75 -0.0786 0.0146 E136806000039 140.68 -0.0594 0.0190 E136806000040 145.61 -0.0037 0.0163 E136806000041 150.53 0.0565 0.0157 E136806000042 155.45 -0.0213 0.0147 E136806000043 160.36 -0.0632 0.0145 E136806000044 165.27 -0.0800 0.0159 E136806000045 170.18 -0.1155 0.0183 E136806000046 ENDDATA 24 0 E136806000047 ENDSUBENT 46 0 E136806099999 SUBENT E1368061 20080131 E051E136806100001 BIB 7 13 E136806100002 REACTION (46-PD-110(D,EL)46-PD-110,22,POL/DA,,TAP) E136806100003 EN-SEC ANG is polar angle between beam and deuteron in E136806100004 laboratory system E136806100005 SAMPLE - Target enrichment is 97.73%. E136806100006 - Target-thickness is 2.26 mg/cm**2. E136806100007 METHOD (EDE) E136806100008 DETECTOR Solid angle of detector is 2 msr. E136806100009 (MAGSP,SWPC) To momentum analyze and detect scattered E136806100010 deuteron E136806100011 ERR-ANALYS (ERR-T) Total uncertainty E136806100012 (ERR-1) Uncertainty due to measured beam polarizations E136806100013 STATUS (TABLE) Data (Fig.1, p47 in main reference) taken from E136806100014 doctor thesis of M.Takei E136806100015 ENDBIB 13 0 E136806100016 COMMON 3 3 E136806100017 EN ANG-ERR ERR-1 E136806100018 MEV ADEG PER-CENT E136806100019 21. 1.5 2. E136806100020 ENDCOMMON 3 0 E136806100021 DATA 3 23 E136806100022 ANG-CM DATA ERR-T E136806100023 ADEG NO-DIM NO-DIM E136806100024 60.90 -0.0095 0.0057 E136806100025 65.94 -0.0116 0.0060 E136806100026 70.98 -0.0068 0.0060 E136806100027 76.01 -0.0114 0.0079 E136806100028 81.03 -0.0368 0.0073 E136806100029 86.04 -0.0031 0.0089 E136806100030 91.04 0.0218 0.0088 E136806100031 96.04 -0.0094 0.0105 E136806100032 101.03 -0.0546 0.0129 E136806100033 106.01 -0.1095 0.0141 E136806100034 110.98 -0.0579 0.0137 E136806100035 115.94 -0.0084 0.0167 E136806100036 120.90 0.0394 0.0167 E136806100037 125.85 -0.0044 0.0166 E136806100038 130.80 -0.0700 0.0178 E136806100039 135.74 -0.0845 0.0177 E136806100040 140.67 0.0123 0.0184 E136806100041 145.60 0.0856 0.0190 E136806100042 150.52 0.0703 0.0190 E136806100043 155.44 -0.0275 0.0188 E136806100044 160.36 -0.0482 0.0185 E136806100045 165.27 -0.0479 0.0200 E136806100046 170.18 -0.0241 0.0225 E136806100047 ENDDATA 25 0 E136806100048 ENDSUBENT 47 0 E136806199999 NOSUBENT E1368062 20080131 E051E136806200001 NOSUBENT E1368063 20080131 E051E136806300001 NOSUBENT E1368064 20080131 E051E136806400001 NOSUBENT E1368065 20080131 E051E136806500001 NOSUBENT E1368066 20080131 E051E136806600001 NOSUBENT E1368067 20080131 E051E136806700001 NOSUBENT E1368068 20080131 E051E136806800001 NOSUBENT E1368069 20080131 E051E136806900001 NOSUBENT E1368070 20080131 E051E136807000001 NOSUBENT E1368071 20080131 E051E136807100001 NOSUBENT E1368072 20080131 E051E136807200001 NOSUBENT E1368073 20080131 E051E136807300001 ENDENTRY 73 0 E136899999999