ENTRY E1703 20060906 E037E170300000001 SUBENT E1703001 20060906 E037E170300100001 BIB 8 35 E170300100002 TITLE Particle decays from 12B and 12N mirror nuclei E170300100003 AUTHOR (T.Inomata, H.Akimune, I.Daito, H.Ejiri, H.Fujimura, E170300100004 Y.Fujita, M.Fujiwara, M.N.Harakeh, K.Ishibashi, E170300100005 H.Kohri, N.Matsuoka, S.Nakayama, A.Tamii, M.Tanaka, E170300100006 H.Toyokawa, M.Yoshimura, M.Yosoi) E170300100007 INSTITUTE (2JPNOSA) Research Center for Nuclear Physics E170300100008 (2JPNOSA) Department of Physics E170300100009 (2NEDKVI) E170300100010 (2JPNTKS) Department of Physics E170300100011 (2JPNKTO) Department of Physics E170300100012 (2JPNKTJ) E170300100013 (2JPNJSR) E170300100014 REFERENCE (J,PR/C,57,(6),3153,199806) E170300100015 SAMPLE - Target is natural. E170300100016 - Chemical-form of target is element. E170300100017 - Physical-form of target is solid. E170300100018 - Backing is unknown. E170300100019 FACILITY (CYCLO,2JPNOSA) Research Center for Nuclear Physics E170300100020 ADD-RES E1703.031:6-C-12(HE3,T+P)6-C-11 E170300100021 Angular correlation E170300100022 See NRDF D1703 DATA,30 for detail. E170300100023 E1703.032:6-C-12(HE3,T+P)6-C-11 E170300100024 Angular correlation E170300100025 See NRDF D1703 DATA,31 for detail. E170300100026 E1703.033:6-C-12(HE3,T+P)6-C-11 E170300100027 Angular correlation E170300100028 See NRDF D1703 DATA,32 for detail. E170300100029 E1703.034:6-C-12(HE3,T+P)6-C-11 E170300100030 Angular correlation E170300100031 See NRDF D1703 DATA,33 for detail. E170300100032 E1703.035:6-C-12(HE3,T+P)6-C-11 E170300100033 Angular correlation E170300100034 See NRDF D1703 DATA,34 for detail. E170300100035 HISTORY (20020705T) Ay + Am. Data converted from NRDF D1703 E170300100036 (20041125A) On. INSTITUTE and REFERENCE corrected E170300100037 ENDBIB 35 0 E170300100038 NOCOMMON 0 0 E170300100039 ENDSUBENT 38 0 E170300199999 SUBENT E1703002 20060906 E037E170300200001 BIB 11 23 E170300200002 REACTION (6-C-12(D,HE2+N)5-B-11,SEQ/PAR,DA/DA,N/HE2,REL) E170300200003 PART-DET (N,HE2) E170300200004 EN-SEC - ANG1 is polar angle between beam and 2He in E170300200005 laboratory system E170300200006 - ANG2-CM is polar angle between beam and neutron in E170300200007 center of mass system E170300200008 (E-LVL1,5-B-11) E170300200009 (E-LVL2,5-B-12) E170300200010 INC-SOURCE Beam intensity is less than 0.05 nA. E170300200011 SAMPLE Target-thickness is 30 mg/cm**2. E170300200012 METHOD (COINC) Detect 2He and neutron in coincidence. E170300200013 DETECTOR - Solid angle of detector is 2.4 msr.(for E170300200014 Large-acceptance spectrometer (LAS)) E170300200015 - E-RSL: for final-state spectrum of neutron E170300200016 (MAGSP) With plastic scintillator to detect two E170300200017 protons decay from 2He E170300200018 (SCIN) To detect decay neutron from 12B E170300200019 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170300200020 ADD-RES (COMP) ANGCOR, See [M. N. Harakeh and L. W. Put, KVI E170300200021 internal report, KVI 67 (1979)]. E170300200022 STATUS (CURVE) Data scanned from Fig.6, p3159 in reference E170300200023 HISTORY (20050812A) On. REACTION corrected (CP-C/350) E170300200024 (20060627A) At. Re-digitized E170300200025 ENDBIB 23 0 E170300200026 COMMON 5 3 E170300200027 EN E-RSL ANG1 E-LVL1 E-LVL2 E170300200028 MEV KEV ADEG MEV MEV E170300200029 200. 600. 0. 0.0 7.7 E170300200030 ENDCOMMON 3 0 E170300200031 DATA 3 11 E170300200032 ANG2-CM DATA DATA-ERR E170300200033 ADEG ARB-UNITS ARB-UNITS E170300200034 1.005E+02 8.554E-02 4.888E-03 E170300200035 1.076E+02 8.147E-02 7.739E-03 E170300200036 1.147E+02 7.739E-02 1.018E-02 E170300200037 1.217E+02 7.658E-02 3.666E-03 E170300200038 1.285E+02 7.739E-02 5.295E-03 E170300200039 1.353E+02 7.169E-02 3.259E-03 E170300200040 1.417E+02 7.699E-02 3.666E-03 E170300200041 1.480E+02 6.639E-02 3.666E-03 E170300200042 1.520E+02 5.010E-02 6.517E-03 E170300200043 1.557E+02 6.232E-02 4.888E-03 E170300200044 1.607E+02 5.784E-02 6.517E-03 E170300200045 ENDDATA 13 0 E170300200046 ENDSUBENT 45 0 E170300299999 SUBENT E1703003 20060906 E037E170300300001 BIB 12 24 E170300300002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170300300003 PART-DET (T,P) E170300300004 EN-SEC - ANG1 is polar angle between beam and triton in E170300300005 laboratory system E170300300006 - ANG2-CM is polar angle between beam and proton in E170300300007 center of mass system E170300300008 (E-EXC,7-N-12) E170300300009 (E-LVL,6-C-11) E170300300010 LEVEL-PROP (6-C-11,E-LVL=0.0,SPIN=1.5,PARITY=-1.) E170300300011 INC-SOURCE Beam intensity is less than 3 nA. E170300300012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170300300013 METHOD (COINC) Detect triton and proton in coincidence. E170300300014 DETECTOR - Solid angle: 3% of 4pi E170300300015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170300300016 solid-state detector) E170300300017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170300300018 [M.Fujiwara et al., Proceedings of the 5th E170300300019 French-Japanese Symposium on Nuclear Physics, E170300300020 Dogashima, Japan, 1989, p.348]. E170300300021 (SILI) To measure decay protons E170300300022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170300300023 ADD-RES (COMP) Legendre polynomials analysis E170300300024 STATUS (CURVE) Data scanned from Fig.9, p3160 in reference E170300300025 HISTORY (20060627A) At. Re-digitized E170300300026 ENDBIB 24 0 E170300300027 COMMON 5 3 E170300300028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170300300029 MEV ADEG MEV MEV MEV E170300300030 450. 0. 3.0 5.0 0.0 E170300300031 ENDCOMMON 3 0 E170300300032 DATA 3 6 E170300300033 ANG2-CM DATA DATA-ERR E170300300034 ADEG MUB/SR2 MUB/SR2 E170300300035 1.126E+02 1.749E+02 3.456E+00 E170300300036 1.223E+02 1.837E+02 4.992E+00 E170300300037 1.320E+02 1.910E+02 2.688E+00 E170300300038 1.418E+02 2.160E+02 3.456E+00 E170300300039 1.514E+02 2.348E+02 3.072E+00 E170300300040 1.610E+02 2.373E+02 2.308E+00 E170300300041 ENDDATA 8 0 E170300300042 ENDSUBENT 41 0 E170300399999 SUBENT E1703004 20060906 E037E170300400001 BIB 12 24 E170300400002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170300400003 PART-DET (T,P) E170300400004 EN-SEC - ANG1 is polar angle between beam and triton in E170300400005 laboratory system E170300400006 - ANG2-CM is polar angle between beam and proton in E170300400007 center of mass system E170300400008 (E-EXC,7-N-12) E170300400009 (E-LVL,6-C-11) E170300400010 LEVEL-PROP (6-C-11,E-LVL=0.0,SPIN=1.5,PARITY=-1.) E170300400011 INC-SOURCE Beam intensity is less than 3 nA. E170300400012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170300400013 METHOD (COINC) Detect triton and proton in coincidence. E170300400014 DETECTOR - Solid angle: 3% of 4pi E170300400015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170300400016 solid-state detector) E170300400017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170300400018 [M.Fujiwara et al., Proceedings of the 5th E170300400019 French-Japanese Symposium on Nuclear Physics, E170300400020 Dogashima, Japan, 1989, p.348]. E170300400021 (SILI) To measure decay protons E170300400022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170300400023 ADD-RES (COMP) Legendre polynomials analysis E170300400024 STATUS (CURVE) Data scanned from Fig.9, p3160 in reference E170300400025 HISTORY (20060627A) At. Re-digitized E170300400026 ENDBIB 24 0 E170300400027 COMMON 5 3 E170300400028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170300400029 MEV ADEG MEV MEV MEV E170300400030 450. 0. 3.5 4.5 0.0 E170300400031 ENDCOMMON 3 0 E170300400032 DATA 3 6 E170300400033 ANG2-CM DATA DATA-ERR E170300400034 ADEG MUB/SR2 MUB/SR2 E170300400035 1.124E+02 1.419E+02 4.959E+00 E170300400036 1.222E+02 1.434E+02 3.654E+00 E170300400037 1.320E+02 1.489E+02 2.349E+00 E170300400038 1.417E+02 1.593E+02 2.349E+00 E170300400039 1.514E+02 1.759E+02 2.606E+00 E170300400040 1.610E+02 1.777E+02 2.866E+00 E170300400041 ENDDATA 8 0 E170300400042 ENDSUBENT 41 0 E170300499999 SUBENT E1703005 20060906 E037E170300500001 BIB 12 24 E170300500002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170300500003 PART-DET (T,P) E170300500004 EN-SEC - ANG1 is polar angle between beam and triton in E170300500005 laboratory system E170300500006 - ANG2-CM is polar angle between beam and proton in E170300500007 center of mass system E170300500008 (E-EXC,7-N-12) E170300500009 (E-LVL,6-C-11) E170300500010 LEVEL-PROP (6-C-11,E-LVL=0.0,SPIN=1.5,PARITY=-1.) E170300500011 INC-SOURCE Beam intensity is less than 3 nA. E170300500012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170300500013 METHOD (COINC) Detect triton and proton in coincidence. E170300500014 DETECTOR - Solid angle: 3% of 4pi E170300500015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170300500016 solid-state detector) E170300500017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170300500018 [M.Fujiwara et al., Proceedings of the 5th E170300500019 French-Japanese Symposium on Nuclear Physics, E170300500020 Dogashima, Japan, 1989, p.348]. E170300500021 (SILI) To measure decay protons E170300500022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170300500023 ADD-RES (COMP) Legendre polynomials analysis E170300500024 STATUS (CURVE) Data scanned from Fig.9, p3160 in reference E170300500025 HISTORY (20060627A) At. Re-digitized E170300500026 ENDBIB 24 0 E170300500027 COMMON 5 3 E170300500028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170300500029 MEV ADEG MEV MEV MEV E170300500030 450. 0. 4.5 5.0 0.0 E170300500031 ENDCOMMON 3 0 E170300500032 DATA 3 6 E170300500033 ANG2-CM DATA DATA-ERR E170300500034 ADEG MUB/SR2 MUB/SR2 E170300500035 1.124E+02 3.662E+01 1.538E+00 E170300500036 1.223E+02 3.923E+01 E170300500037 1.321E+02 4.215E+01 1.231E+00 E170300500038 1.417E+02 5.415E+01 9.231E-01 E170300500039 1.513E+02 5.554E+01 1.077E+00 E170300500040 1.611E+02 6.138E+01 1.692E+00 E170300500041 ENDDATA 8 0 E170300500042 ENDSUBENT 41 0 E170300599999 SUBENT E1703006 20060906 E037E170300600001 BIB 12 24 E170300600002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170300600003 PART-DET (T,P) E170300600004 EN-SEC - ANG1 is polar angle between beam and triton in E170300600005 laboratory system E170300600006 - ANG2-CM is polar angle between beam and proton in E170300600007 center of mass system E170300600008 (E-EXC,7-N-12) E170300600009 (E-LVL,6-C-11) E170300600010 LEVEL-PROP (6-C-11,E-LVL=0.0,SPIN=1.5,PARITY=-1.) E170300600011 INC-SOURCE Beam intensity is less than 3 nA. E170300600012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170300600013 METHOD (COINC) Detect triton and proton in coincidence. E170300600014 DETECTOR - Solid angle: 3% of 4pi E170300600015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170300600016 solid-state detector) E170300600017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170300600018 [M.Fujiwara et al., Proceedings of the 5th E170300600019 French-Japanese Symposium on Nuclear Physics, E170300600020 Dogashima, Japan, 1989, p.348]. E170300600021 (SILI) To measure decay protons E170300600022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170300600023 ADD-RES (COMP) Legendre polynomials analysis E170300600024 STATUS (CURVE) Data scanned from Fig.9, p3160 in reference E170300600025 HISTORY (20060627A) At. Re-digitized E170300600026 ENDBIB 24 0 E170300600027 COMMON 5 3 E170300600028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170300600029 MEV ADEG MEV MEV MEV E170300600030 450. 0. 5.0 7.0 0.0 E170300600031 ENDCOMMON 3 0 E170300600032 DATA 3 6 E170300600033 ANG2-CM DATA DATA-ERR E170300600034 ADEG MUB/SR2 MUB/SR2 E170300600035 1.125E+02 1.401E+02 3.067E+00 E170300600036 1.221E+02 1.562E+02 E170300600037 1.319E+02 1.758E+02 2.684E+00 E170300600038 1.416E+02 1.995E+02 E170300600039 1.513E+02 2.183E+02 3.834E+00 E170300600040 1.609E+02 2.268E+02 3.067E+00 E170300600041 ENDDATA 8 0 E170300600042 ENDSUBENT 41 0 E170300699999 SUBENT E1703007 20060906 E037E170300700001 BIB 12 24 E170300700002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170300700003 PART-DET (T,P) E170300700004 EN-SEC - ANG1 is polar angle between beam and triton in E170300700005 laboratory system E170300700006 - ANG2-CM is polar angle between beam and proton in E170300700007 center of mass system E170300700008 (E-EXC,7-N-12) E170300700009 (E-LVL,6-C-11) E170300700010 LEVEL-PROP (6-C-11,E-LVL=0.0,SPIN=1.5,PARITY=-1.) E170300700011 INC-SOURCE Beam intensity is less than 3 nA. E170300700012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170300700013 METHOD (COINC) Detect triton and proton in coincidence. E170300700014 DETECTOR - Solid angle: 3% of 4pi E170300700015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170300700016 solid-state detector) E170300700017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170300700018 [M.Fujiwara et al., Proceedings of the 5th E170300700019 French-Japanese Symposium on Nuclear Physics, E170300700020 Dogashima, Japan, 1989, p.348]. E170300700021 (SILI) To measure decay protons E170300700022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170300700023 ADD-RES (COMP) Legendre polynomials analysis E170300700024 STATUS (CURVE) Data scanned from Fig.9, p3160 in reference E170300700025 HISTORY (20060627A) At. Re-digitized E170300700026 ENDBIB 24 0 E170300700027 COMMON 5 3 E170300700028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170300700029 MEV ADEG MEV MEV MEV E170300700030 450. 0. 7.0 8.0 0.0 E170300700031 ENDCOMMON 3 0 E170300700032 DATA 3 6 E170300700033 ANG2-CM DATA DATA-ERR E170300700034 ADEG MUB/SR2 MUB/SR2 E170300700035 1.122E+02 5.997E+01 1.104E+00 E170300700036 1.221E+02 6.411E+01 1.196E+00 E170300700037 1.318E+02 6.696E+01 1.012E+00 E170300700038 1.415E+02 6.632E+01 6.442E-01 E170300700039 1.511E+02 7.111E+01 1.285E+00 E170300700040 1.608E+02 7.248E+01 1.840E+00 E170300700041 ENDDATA 8 0 E170300700042 ENDSUBENT 41 0 E170300799999 SUBENT E1703008 20060906 E037E170300800001 BIB 12 24 E170300800002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170300800003 PART-DET (T,P) E170300800004 EN-SEC - ANG1 is polar angle between beam and triton in E170300800005 laboratory system E170300800006 - ANG2-CM is polar angle between beam and proton in E170300800007 center of mass system E170300800008 (E-EXC,7-N-12) E170300800009 (E-LVL,6-C-11) E170300800010 LEVEL-PROP (6-C-11,E-LVL=0.0,SPIN=1.5,PARITY=-1.) E170300800011 INC-SOURCE Beam intensity is less than 3 nA. E170300800012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170300800013 METHOD (COINC) Detect triton and proton in coincidence. E170300800014 DETECTOR - Solid angle: 3% of 4pi E170300800015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170300800016 solid-state detector) E170300800017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170300800018 [M.Fujiwara et al., Proceedings of the 5th E170300800019 French-Japanese Symposium on Nuclear Physics, E170300800020 Dogashima, Japan, 1989, p.348]. E170300800021 (SILI) To measure decay protons E170300800022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170300800023 ADD-RES (COMP) Legendre polynomials analysis E170300800024 STATUS (CURVE) Data scanned from Fig.9, p3160 in reference E170300800025 HISTORY (20060627A) At. Re-digitized E170300800026 ENDBIB 24 0 E170300800027 COMMON 5 3 E170300800028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170300800029 MEV ADEG MEV MEV MEV E170300800030 450. 0. 8.0 9.0 0.0 E170300800031 ENDCOMMON 3 0 E170300800032 DATA 3 6 E170300800033 ANG2-CM DATA DATA-ERR E170300800034 ADEG MUB/SR2 MUB/SR2 E170300800035 1.123E+02 6.218E+01 1.288E+00 E170300800036 1.220E+02 6.798E+01 8.282E-01 E170300800037 1.318E+02 7.248E+01 2.117E+00 E170300800038 1.414E+02 7.598E+01 1.104E+00 E170300800039 1.511E+02 7.920E+01 6.442E-01 E170300800040 1.607E+02 7.948E+01 1.472E+00 E170300800041 ENDDATA 8 0 E170300800042 ENDSUBENT 41 0 E170300899999 SUBENT E1703009 20060906 E037E170300900001 BIB 12 24 E170300900002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170300900003 PART-DET (T,P) E170300900004 EN-SEC - ANG1 is polar angle between beam and triton in E170300900005 laboratory system E170300900006 - ANG2-CM is polar angle between beam and proton in E170300900007 center of mass system E170300900008 (E-EXC,7-N-12) E170300900009 (E-LVL,6-C-11) E170300900010 LEVEL-PROP (6-C-11,E-LVL=0.0,SPIN=1.5,PARITY=-1.) E170300900011 INC-SOURCE Beam intensity is less than 3 nA. E170300900012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170300900013 METHOD (COINC) Detect triton and proton in coincidence. E170300900014 DETECTOR - Solid angle: 3% of 4pi E170300900015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170300900016 solid-state detector) E170300900017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170300900018 [M.Fujiwara et al., Proceedings of the 5th E170300900019 French-Japanese Symposium on Nuclear Physics, E170300900020 Dogashima, Japan, 1989, p.348]. E170300900021 (SILI) To measure decay protons E170300900022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170300900023 ADD-RES (COMP) Legendre polynomials analysis E170300900024 STATUS (CURVE) Data scanned from Fig.10, p3160 in reference E170300900025 HISTORY (20060627A) At. Re-digitized E170300900026 ENDBIB 24 0 E170300900027 COMMON 5 3 E170300900028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170300900029 MEV ADEG MEV MEV MEV E170300900030 450. 0. 9.0 11.0 0.0 E170300900031 ENDCOMMON 3 0 E170300900032 DATA 3 6 E170300900033 ANG2-CM DATA DATA-ERR E170300900034 ADEG MUB/SR2 MUB/SR2 E170300900035 1.120E+02 6.995E+01 1.426E+00 E170300900036 1.219E+02 7.073E+01 2.204E+00 E170300900037 1.317E+02 7.579E+01 1.297E+00 E170300900038 1.415E+02 8.629E+01 1.556E+00 E170300900039 1.512E+02 8.577E+01 1.037E+00 E170300900040 1.608E+02 7.812E+01 2.593E+00 E170300900041 ENDDATA 8 0 E170300900042 ENDSUBENT 41 0 E170300999999 SUBENT E1703010 20060906 E037E170301000001 BIB 12 24 E170301000002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170301000003 PART-DET (T,P) E170301000004 EN-SEC - ANG1 is polar angle between beam and triton in E170301000005 laboratory system E170301000006 - ANG2-CM is polar angle between beam and proton in E170301000007 center of mass system E170301000008 (E-EXC,7-N-12) E170301000009 (E-LVL,6-C-11) E170301000010 LEVEL-PROP (6-C-11,E-LVL=0.0,SPIN=1.5,PARITY=-1.) E170301000011 INC-SOURCE Beam intensity is less than 3 nA. E170301000012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170301000013 METHOD (COINC) Detect triton and proton in coincidence. E170301000014 DETECTOR - Solid angle: 3% of 4pi E170301000015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170301000016 solid-state detector) E170301000017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170301000018 [M.Fujiwara et al., Proceedings of the 5th E170301000019 French-Japanese Symposium on Nuclear Physics, E170301000020 Dogashima, Japan, 1989, p.348]. E170301000021 (SILI) To measure decay protons E170301000022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170301000023 ADD-RES (COMP) Legendre polynomials analysis E170301000024 STATUS (CURVE) Data scanned from Fig.10, p3160 in reference E170301000025 HISTORY (20060627A) At. Re-digitized E170301000026 ENDBIB 24 0 E170301000027 COMMON 5 3 E170301000028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170301000029 MEV ADEG MEV MEV MEV E170301000030 450. 0. 11.0 13.0 0.0 E170301000031 ENDCOMMON 3 0 E170301000032 DATA 3 6 E170301000033 ANG2-CM DATA DATA-ERR E170301000034 ADEG MUB/SR2 MUB/SR2 E170301000035 1.120E+02 4.376E+01 1.783E+00 E170301000036 1.219E+02 4.716E+01 1.135E+00 E170301000037 1.315E+02 5.284E+01 E170301000038 1.415E+02 6.207E+01 1.459E+00 E170301000039 1.512E+02 6.224E+01 1.945E+00 E170301000040 1.608E+02 5.737E+01 1.459E+00 E170301000041 ENDDATA 8 0 E170301000042 ENDSUBENT 41 0 E170301099999 SUBENT E1703011 20060906 E037E170301100001 BIB 12 24 E170301100002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170301100003 PART-DET (T,P) E170301100004 EN-SEC - ANG1 is polar angle between beam and triton in E170301100005 laboratory system E170301100006 - ANG2-CM is polar angle between beam and proton in E170301100007 center of mass system E170301100008 (E-EXC,7-N-12) E170301100009 (E-LVL,6-C-11) E170301100010 LEVEL-PROP (6-C-11,E-LVL=0.0,SPIN=1.5,PARITY=-1.) E170301100011 INC-SOURCE Beam intensity is less than 3 nA. E170301100012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170301100013 METHOD (COINC) Detect triton and proton in coincidence. E170301100014 DETECTOR - Solid angle: 3% of 4pi E170301100015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170301100016 solid-state detector) E170301100017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170301100018 [M.Fujiwara et al., Proceedings of the 5th E170301100019 French-Japanese Symposium on Nuclear Physics, E170301100020 Dogashima, Japan, 1989, p.348]. E170301100021 (SILI) To measure decay protons E170301100022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170301100023 ADD-RES (COMP) Legendre polynomials analysis E170301100024 STATUS (CURVE) Data scanned from Fig.10, p3160 in reference E170301100025 HISTORY (20060627A) At. Re-digitized E170301100026 ENDBIB 24 0 E170301100027 COMMON 5 3 E170301100028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170301100029 MEV ADEG MEV MEV MEV E170301100030 450. 0. 13.0 15.0 0.0 E170301100031 ENDCOMMON 3 0 E170301100032 DATA 3 6 E170301100033 ANG2-CM DATA DATA-ERR E170301100034 ADEG MUB/SR2 MUB/SR2 E170301100035 1.120E+02 3.646E+01 7.748E-01 E170301100036 1.219E+02 4.034E+01 1.162E+00 E170301100037 1.315E+02 4.363E+01 1.646E+00 E170301100038 1.414E+02 4.944E+01 9.685E-01 E170301100039 1.511E+02 5.215E+01 8.717E-01 E170301100040 1.608E+02 4.915E+01 7.748E-01 E170301100041 ENDDATA 8 0 E170301100042 ENDSUBENT 41 0 E170301199999 SUBENT E1703012 20060906 E037E170301200001 BIB 12 24 E170301200002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170301200003 PART-DET (T,P) E170301200004 EN-SEC - ANG1 is polar angle between beam and triton in E170301200005 laboratory system E170301200006 - ANG2-CM is polar angle between beam and proton in E170301200007 center of mass system E170301200008 (E-EXC,7-N-12) E170301200009 (E-LVL,6-C-11) E170301200010 LEVEL-PROP (6-C-11,E-LVL=0.0,SPIN=1.5,PARITY=-1.) E170301200011 INC-SOURCE Beam intensity is less than 3 nA. E170301200012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170301200013 METHOD (COINC) Detect triton and proton in coincidence. E170301200014 DETECTOR - Solid angle: 3% of 4pi E170301200015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170301200016 solid-state detector) E170301200017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170301200018 [M.Fujiwara et al., Proceedings of the 5th E170301200019 French-Japanese Symposium on Nuclear Physics, E170301200020 Dogashima, Japan, 1989, p.348]. E170301200021 (SILI) To measure decay protons E170301200022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170301200023 ADD-RES (COMP) Legendre polynomials analysis E170301200024 STATUS (CURVE) Data scanned from Fig.10, p3160 in reference E170301200025 HISTORY (20060627A) At. Re-digitized E170301200026 ENDBIB 24 0 E170301200027 COMMON 5 3 E170301200028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170301200029 MEV ADEG MEV MEV MEV E170301200030 450. 0. 15.0 20.0 0.0 E170301200031 ENDCOMMON 3 0 E170301200032 DATA 3 6 E170301200033 ANG2-CM DATA DATA-ERR E170301200034 ADEG MUB/SR2 MUB/SR2 E170301200035 1.120E+02 7.229E+01 1.621E+00 E170301200036 1.219E+02 7.520E+01 2.998E+00 E170301200037 1.316E+02 7.318E+01 1.378E+00 E170301200038 1.413E+02 7.715E+01 2.593E+00 E170301200039 1.510E+02 8.144E+01 2.512E+00 E170301200040 1.606E+02 7.334E+01 1.540E+00 E170301200041 ENDDATA 8 0 E170301200042 ENDSUBENT 41 0 E170301299999 SUBENT E1703013 20060906 E037E170301300001 BIB 12 24 E170301300002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170301300003 PART-DET (T,P) E170301300004 EN-SEC - ANG1 is polar angle between beam and triton in E170301300005 laboratory system E170301300006 - ANG2-CM is polar angle between beam and proton in E170301300007 center of mass system E170301300008 (E-EXC,7-N-12) E170301300009 (E-LVL,6-C-11) E170301300010 LEVEL-PROP (6-C-11,E-LVL=0.0,SPIN=1.5,PARITY=-1.) E170301300011 INC-SOURCE Beam intensity is less than 3 nA. E170301300012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170301300013 METHOD (COINC) Detect triton and proton in coincidence. E170301300014 DETECTOR - Solid angle: 3% of 4pi E170301300015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170301300016 solid-state detector) E170301300017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170301300018 [M.Fujiwara et al., Proceedings of the 5th E170301300019 French-Japanese Symposium on Nuclear Physics, E170301300020 Dogashima, Japan, 1989, p.348]. E170301300021 (SILI) To measure decay protons E170301300022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170301300023 ADD-RES (COMP) Legendre polynomials analysis E170301300024 STATUS (CURVE) Data scanned from Fig.10, p3160 in reference E170301300025 HISTORY (20060627A) At. Re-digitized E170301300026 ENDBIB 24 0 E170301300027 COMMON 5 3 E170301300028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170301300029 MEV ADEG MEV MEV MEV E170301300030 450. 0. 20.0 25.0 0.0 E170301300031 ENDCOMMON 3 0 E170301300032 DATA 3 6 E170301300033 ANG2-CM DATA DATA-ERR E170301300034 ADEG MUB/SR2 MUB/SR2 E170301300035 1.120E+02 4.681E+01 7.780E-01 E170301300036 1.219E+02 4.019E+01 1.815E+00 E170301300037 1.316E+02 3.423E+01 1.426E+00 E170301300038 1.413E+02 3.138E+01 1.167E+00 E170301300039 1.510E+02 3.047E+01 1.037E+00 E170301300040 1.606E+02 2.788E+01 1.556E+00 E170301300041 ENDDATA 8 0 E170301300042 ENDSUBENT 41 0 E170301399999 SUBENT E1703014 20060906 E037E170301400001 BIB 12 24 E170301400002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170301400003 PART-DET (T,P) E170301400004 EN-SEC - ANG1 is polar angle between beam and triton in E170301400005 laboratory system E170301400006 - ANG2-CM is polar angle between beam and proton in E170301400007 center of mass system E170301400008 (E-EXC,7-N-12) E170301400009 (E-LVL,6-C-11) E170301400010 LEVEL-PROP (6-C-11,E-LVL=2.0,SPIN=0.5,PARITY=-1.) E170301400011 INC-SOURCE Beam intensity is less than 3 nA. E170301400012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170301400013 METHOD (COINC) Detect triton and proton in coincidence. E170301400014 DETECTOR - Solid angle: 3% of 4pi E170301400015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170301400016 solid-state detector) E170301400017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170301400018 [M.Fujiwara et al., Proceedings of the 5th E170301400019 French-Japanese Symposium on Nuclear Physics, E170301400020 Dogashima, Japan, 1989, p.348]. E170301400021 (SILI) To measure decay protons E170301400022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170301400023 ADD-RES (COMP) Legendre polynomials analysis E170301400024 STATUS (CURVE) Data scanned from Fig.11, p3160 in reference E170301400025 HISTORY (20060627A) At. Re-digitized E170301400026 ENDBIB 24 0 E170301400027 COMMON 5 3 E170301400028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170301400029 MEV ADEG MEV MEV MEV E170301400030 450. 0. 5.0 7.0 2.0 E170301400031 ENDCOMMON 3 0 E170301400032 DATA 3 6 E170301400033 ANG2-CM DATA DATA-ERR E170301400034 ADEG MUB/SR2 MUB/SR2 E170301400035 1.126E+02 5.464E+01 5.400E+00 E170301400036 1.225E+02 5.486E+01 2.592E+00 E170301400037 1.322E+02 5.292E+01 3.024E+00 E170301400038 1.420E+02 4.600E+01 1.728E+00 E170301400039 1.516E+02 4.708E+01 3.456E+00 E170301400040 1.611E+02 5.983E+01 9.287E+00 E170301400041 ENDDATA 8 0 E170301400042 ENDSUBENT 41 0 E170301499999 SUBENT E1703015 20060906 E037E170301500001 BIB 12 24 E170301500002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170301500003 PART-DET (T,P) E170301500004 EN-SEC - ANG1 is polar angle between beam and triton in E170301500005 laboratory system E170301500006 - ANG2-CM is polar angle between beam and proton in E170301500007 center of mass system E170301500008 (E-EXC,7-N-12) E170301500009 (E-LVL,6-C-11) E170301500010 LEVEL-PROP (6-C-11,E-LVL=2.0,SPIN=0.5,PARITY=-1.) E170301500011 INC-SOURCE Beam intensity is less than 3 nA. E170301500012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170301500013 METHOD (COINC) Detect triton and proton in coincidence. E170301500014 DETECTOR - Solid angle: 3% of 4pi E170301500015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170301500016 solid-state detector) E170301500017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170301500018 [M.Fujiwara et al., Proceedings of the 5th E170301500019 French-Japanese Symposium on Nuclear Physics, E170301500020 Dogashima, Japan, 1989, p.348]. E170301500021 (SILI) To measure decay protons E170301500022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170301500023 ADD-RES (COMP) Legendre polynomials analysis E170301500024 STATUS (CURVE) Data scanned from Fig.11, p3160 in reference E170301500025 HISTORY (20060627A) At. Re-digitized E170301500026 ENDBIB 24 0 E170301500027 COMMON 5 3 E170301500028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170301500029 MEV ADEG MEV MEV MEV E170301500030 450. 0. 7.0 8.0 2.0 E170301500031 ENDCOMMON 3 0 E170301500032 DATA 3 6 E170301500033 ANG2-CM DATA DATA-ERR E170301500034 ADEG MUB/SR2 MUB/SR2 E170301500035 1.123E+02 3.095E+01 2.672E+00 E170301500036 1.221E+02 2.957E+01 2.414E+00 E170301500037 1.320E+02 3.069E+01 1.724E+00 E170301500038 1.417E+02 3.224E+01 2.069E+00 E170301500039 1.515E+02 3.517E+01 1.293E+00 E170301500040 1.611E+02 3.388E+01 1.207E+00 E170301500041 ENDDATA 8 0 E170301500042 ENDSUBENT 41 0 E170301599999 SUBENT E1703016 20060906 E037E170301600001 BIB 12 24 E170301600002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170301600003 PART-DET (T,P) E170301600004 EN-SEC - ANG1 is polar angle between beam and triton in E170301600005 laboratory system E170301600006 - ANG2-CM is polar angle between beam and proton in E170301600007 center of mass system E170301600008 (E-EXC,7-N-12) E170301600009 (E-LVL,6-C-11) E170301600010 LEVEL-PROP (6-C-11,E-LVL=2.0,SPIN=0.5,PARITY=-1.) E170301600011 INC-SOURCE Beam intensity is less than 3 nA. E170301600012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170301600013 METHOD (COINC) Detect triton and proton in coincidence. E170301600014 DETECTOR - Solid angle: 3% of 4pi E170301600015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170301600016 solid-state detector) E170301600017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170301600018 [M.Fujiwara et al., Proceedings of the 5th E170301600019 French-Japanese Symposium on Nuclear Physics, E170301600020 Dogashima, Japan, 1989, p.348]. E170301600021 (SILI) To measure decay protons E170301600022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170301600023 ADD-RES (COMP) Legendre polynomials analysis E170301600024 STATUS (CURVE) Data scanned from Fig.11, p3160 in reference E170301600025 HISTORY (20060627A) At. Re-digitized E170301600026 ENDBIB 24 0 E170301600027 COMMON 5 3 E170301600028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170301600029 MEV ADEG MEV MEV MEV E170301600030 450. 0. 8.0 9.0 2.0 E170301600031 ENDCOMMON 3 0 E170301600032 DATA 3 6 E170301600033 ANG2-CM DATA DATA-ERR E170301600034 ADEG MUB/SR2 MUB/SR2 E170301600035 1.123E+02 3.427E+01 1.032E+00 E170301600036 1.222E+02 3.221E+01 1.719E+00 E170301600037 1.320E+02 3.436E+01 2.149E+00 E170301600038 1.417E+02 3.496E+01 8.596E-01 E170301600039 1.514E+02 3.582E+01 1.891E+00 E170301600040 1.611E+02 3.573E+01 1.805E+00 E170301600041 ENDDATA 8 0 E170301600042 ENDSUBENT 41 0 E170301699999 SUBENT E1703017 20060906 E037E170301700001 BIB 12 24 E170301700002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170301700003 PART-DET (T,P) E170301700004 EN-SEC - ANG1 is polar angle between beam and triton in E170301700005 laboratory system E170301700006 - ANG2-CM is polar angle between beam and proton in E170301700007 center of mass system E170301700008 (E-EXC,7-N-12) E170301700009 (E-LVL,6-C-11) E170301700010 LEVEL-PROP (6-C-11,E-LVL=2.0,SPIN=0.5,PARITY=-1.) E170301700011 INC-SOURCE Beam intensity is less than 3 nA. E170301700012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170301700013 METHOD (COINC) Detect triton and proton in coincidence. E170301700014 DETECTOR - Solid angle: 3% of 4pi E170301700015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170301700016 solid-state detector) E170301700017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170301700018 [M.Fujiwara et al., Proceedings of the 5th E170301700019 French-Japanese Symposium on Nuclear Physics, E170301700020 Dogashima, Japan, 1989, p.348]. E170301700021 (SILI) To measure decay protons E170301700022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170301700023 ADD-RES (COMP) Legendre polynomials analysis E170301700024 STATUS (CURVE) Data scanned from Fig.11, p3160 in reference E170301700025 HISTORY (20060627A) At. Re-digitized E170301700026 ENDBIB 24 0 E170301700027 COMMON 5 3 E170301700028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170301700029 MEV ADEG MEV MEV MEV E170301700030 450. 0. 9.0 11.0 2.0 E170301700031 ENDCOMMON 3 0 E170301700032 DATA 3 6 E170301700033 ANG2-CM DATA DATA-ERR E170301700034 ADEG MUB/SR2 MUB/SR2 E170301700035 1.100E+02 3.510E+01 3.957E+00 E170301700036 1.201E+02 3.613E+01 2.237E+00 E170301700037 1.301E+02 4.077E+01 3.613E+00 E170301700038 1.401E+02 3.923E+01 2.065E+00 E170301700039 1.500E+02 4.817E+01 3.097E+00 E170301700040 1.601E+02 4.267E+01 2.581E+00 E170301700041 ENDDATA 8 0 E170301700042 ENDSUBENT 41 0 E170301799999 SUBENT E1703018 20060906 E037E170301800001 BIB 12 24 E170301800002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170301800003 PART-DET (T,P) E170301800004 EN-SEC - ANG1 is polar angle between beam and triton in E170301800005 laboratory system E170301800006 - ANG2-CM is polar angle between beam and proton in E170301800007 center of mass system E170301800008 (E-EXC,7-N-12) E170301800009 (E-LVL,6-C-11) E170301800010 LEVEL-PROP (6-C-11,E-LVL=2.0,SPIN=0.5,PARITY=-1.) E170301800011 INC-SOURCE Beam intensity is less than 3 nA. E170301800012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170301800013 METHOD (COINC) Detect triton and proton in coincidence. E170301800014 DETECTOR - Solid angle: 3% of 4pi E170301800015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170301800016 solid-state detector) E170301800017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170301800018 [M.Fujiwara et al., Proceedings of the 5th E170301800019 French-Japanese Symposium on Nuclear Physics, E170301800020 Dogashima, Japan, 1989, p.348]. E170301800021 (SILI) To measure decay protons E170301800022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170301800023 ADD-RES (COMP) Legendre polynomials analysis E170301800024 STATUS (CURVE) Data scanned from Fig.11, p3160 in reference E170301800025 HISTORY (20060627A) At. Re-digitized E170301800026 ENDBIB 24 0 E170301800027 COMMON 5 3 E170301800028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170301800029 MEV ADEG MEV MEV MEV E170301800030 450. 0. 11.0 13.0 2.0 E170301800031 ENDCOMMON 3 0 E170301800032 DATA 3 6 E170301800033 ANG2-CM DATA DATA-ERR E170301800034 ADEG MUB/SR2 MUB/SR2 E170301800035 1.124E+02 2.065E+01 3.118E+00 E170301800036 1.222E+02 2.091E+01 1.724E+00 E170301800037 1.319E+02 2.183E+01 2.903E+00 E170301800038 1.416E+02 2.425E+01 1.078E+00 E170301800039 1.511E+02 2.473E+01 2.796E+00 E170301800040 1.608E+02 2.452E+01 2.366E+00 E170301800041 ENDDATA 8 0 E170301800042 ENDSUBENT 41 0 E170301899999 SUBENT E1703019 20060906 E037E170301900001 BIB 12 24 E170301900002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170301900003 PART-DET (T,P) E170301900004 EN-SEC - ANG1 is polar angle between beam and triton in E170301900005 laboratory system E170301900006 - ANG2-CM is polar angle between beam and proton in E170301900007 center of mass system E170301900008 (E-EXC,7-N-12) E170301900009 (E-LVL,6-C-11) E170301900010 LEVEL-PROP (6-C-11,E-LVL=2.0,SPIN=0.5,PARITY=-1.) E170301900011 INC-SOURCE Beam intensity is less than 3 nA. E170301900012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170301900013 METHOD (COINC) Detect triton and proton in coincidence. E170301900014 DETECTOR - Solid angle: 3% of 4pi E170301900015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170301900016 solid-state detector) E170301900017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170301900018 [M.Fujiwara et al., Proceedings of the 5th E170301900019 French-Japanese Symposium on Nuclear Physics, E170301900020 Dogashima, Japan, 1989, p.348]. E170301900021 (SILI) To measure decay protons E170301900022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170301900023 ADD-RES (COMP) Legendre polynomials analysis E170301900024 STATUS (CURVE) Data scanned from Fig.11, p3160 in reference E170301900025 HISTORY (20060627A) At. Re-digitized E170301900026 ENDBIB 24 0 E170301900027 COMMON 5 3 E170301900028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170301900029 MEV ADEG MEV MEV MEV E170301900030 450. 0. 13.0 15.0 2.0 E170301900031 ENDCOMMON 3 0 E170301900032 DATA 3 6 E170301900033 ANG2-CM DATA DATA-ERR E170301900034 ADEG MUB/SR2 MUB/SR2 E170301900035 1.121E+02 1.534E+01 1.810E+00 E170301900036 1.220E+02 1.509E+01 1.121E+00 E170301900037 1.317E+02 1.966E+01 7.759E-01 E170301900038 1.415E+02 1.845E+01 1.810E+00 E170301900039 1.510E+02 2.052E+01 2.241E+00 E170301900040 1.608E+02 1.888E+01 2.414E+00 E170301900041 ENDDATA 8 0 E170301900042 ENDSUBENT 41 0 E170301999999 SUBENT E1703020 20060906 E037E170302000001 BIB 12 24 E170302000002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170302000003 PART-DET (T,P) E170302000004 EN-SEC - ANG1 is polar angle between beam and triton in E170302000005 laboratory system E170302000006 - ANG2-CM is polar angle between beam and proton in E170302000007 center of mass system E170302000008 (E-EXC,7-N-12) E170302000009 (E-LVL,6-C-11) E170302000010 LEVEL-PROP (6-C-11,E-LVL=2.0,SPIN=0.5,PARITY=-1.) E170302000011 INC-SOURCE Beam intensity is less than 3 nA. E170302000012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170302000013 METHOD (COINC) Detect triton and proton in coincidence. E170302000014 DETECTOR - Solid angle: 3% of 4pi E170302000015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170302000016 solid-state detector) E170302000017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170302000018 [M.Fujiwara et al., Proceedings of the 5th E170302000019 French-Japanese Symposium on Nuclear Physics, E170302000020 Dogashima, Japan, 1989, p.348]. E170302000021 (SILI) To measure decay protons E170302000022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170302000023 ADD-RES (COMP) Legendre polynomials analysis E170302000024 STATUS (CURVE) Data scanned from Fig.11, p3160 in reference E170302000025 HISTORY (20060627A) At. Re-digitized E170302000026 ENDBIB 24 0 E170302000027 COMMON 5 3 E170302000028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170302000029 MEV ADEG MEV MEV MEV E170302000030 450. 0. 15.0 20.0 2.0 E170302000031 ENDCOMMON 3 0 E170302000032 DATA 3 6 E170302000033 ANG2-CM DATA DATA-ERR E170302000034 ADEG MUB/SR2 MUB/SR2 E170302000035 1.123E+02 2.532E+01 1.462E+00 E170302000036 1.221E+02 2.562E+01 1.555E+00 E170302000037 1.318E+02 2.662E+01 2.586E+00 E170302000038 1.415E+02 2.636E+01 2.586E+00 E170302000039 1.511E+02 2.687E+01 7.759E-01 E170302000040 1.608E+02 2.422E+01 1.487E+00 E170302000041 ENDDATA 8 0 E170302000042 ENDSUBENT 41 0 E170302099999 SUBENT E1703021 20060906 E037E170302100001 BIB 12 24 E170302100002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170302100003 PART-DET (T,P) E170302100004 EN-SEC - ANG1 is polar angle between beam and triton in E170302100005 laboratory system E170302100006 - ANG2-CM is polar angle between beam and proton in E170302100007 center of mass system E170302100008 (E-EXC,7-N-12) E170302100009 (E-LVL,6-C-11) E170302100010 LEVEL-PROP (6-C-11,E-LVL=2.0,SPIN=0.5,PARITY=-1.) E170302100011 INC-SOURCE Beam intensity is less than 3 nA. E170302100012 SAMPLE Target-thickness is 2.0 mg/cm**2. E170302100013 METHOD (COINC) Detect triton and proton in coincidence. E170302100014 DETECTOR - Solid angle: 3% of 4pi E170302100015 - Detector resolution is 350 to 450 keV.(for Si(Li) E170302100016 solid-state detector) E170302100017 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170302100018 [M.Fujiwara et al., Proceedings of the 5th E170302100019 French-Japanese Symposium on Nuclear Physics, E170302100020 Dogashima, Japan, 1989, p.348]. E170302100021 (SILI) To measure decay protons E170302100022 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170302100023 ADD-RES (COMP) Legendre polynomials analysis E170302100024 STATUS (CURVE) Data scanned from Fig.11, p3160 in reference E170302100025 HISTORY (20060627A) At. Re-digitized E170302100026 ENDBIB 24 0 E170302100027 COMMON 5 3 E170302100028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170302100029 MEV ADEG MEV MEV MEV E170302100030 450. 0. 20.0 25.0 2.0 E170302100031 ENDCOMMON 3 0 E170302100032 DATA 3 6 E170302100033 ANG2-CM DATA DATA-ERR E170302100034 ADEG MUB/SR2 MUB/SR2 E170302100035 1.121E+02 1.183E+01 1.452E+00 E170302100036 1.219E+02 1.081E+01 8.602E-01 E170302100037 1.317E+02 9.086E+00 1.129E+00 E170302100038 1.415E+02 8.011E+00 8.065E-01 E170302100039 1.511E+02 6.613E+00 7.527E-01 E170302100040 1.608E+02 6.237E+00 1.398E+00 E170302100041 ENDDATA 8 0 E170302100042 ENDSUBENT 41 0 E170302199999 SUBENT E1703022 20060906 E037E170302200001 BIB 11 24 E170302200002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170302200003 PART-DET (T,P) E170302200004 EN-SEC - ANG1 is polar angle between beam and triton in E170302200005 laboratory system E170302200006 - ANG2-CM is polar angle between beam and proton in E170302200007 center of mass system E170302200008 (E-EXC,7-N-12) E170302200009 (E-LVL,6-C-11) E170302200010 INC-SOURCE Beam intensity is less than 3 nA. E170302200011 SAMPLE Target-thickness is 2.0 mg/cm**2. E170302200012 METHOD (COINC) Detect triton and proton in coincidence. E170302200013 DETECTOR - Solid angle: 3% of 4pi E170302200014 - Detector resolution is 350 to 450 keV.(for Si(Li) E170302200015 solid-state detector) E170302200016 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170302200017 [M.Fujiwara et al., Proceedings of the 5th E170302200018 French-Japanese Symposium on Nuclear Physics, E170302200019 Dogashima, Japan, 1989, p.348]. E170302200020 (SILI) To measure decay protons E170302200021 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170302200022 ADD-RES (COMP) Legendre polynomials analysis E170302200023 STATUS (CURVE) Data scanned from Fig.12, p3161 in reference E170302200024 HISTORY (20021119U) On. Zero errors removed E170302200025 (20060627A) At. Re-digitized E170302200026 ENDBIB 24 0 E170302200027 COMMON 6 3 E170302200028 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E-LVL E170302200029 MEV ADEG MEV MEV MEV MEV E170302200030 450. 0. 9.0 11.0 4.3 4.8 E170302200031 ENDCOMMON 3 0 E170302200032 DATA 3 6 E170302200033 ANG2-CM DATA DATA-ERR E170302200034 ADEG MUB/SR2 MUB/SR2 E170302200035 1.130E+02 6.035E+01 1.646E+00 E170302200036 1.228E+02 6.648E+01 2.843E+00 E170302200037 1.325E+02 6.200E+01 1.796E+00 E170302200038 1.422E+02 6.185E+01 2.244E+00 E170302200039 1.517E+02 5.796E+01 8.978E-01 E170302200040 1.613E+02 6.499E+01 4.938E+00 E170302200041 ENDDATA 8 0 E170302200042 ENDSUBENT 41 0 E170302299999 SUBENT E1703023 20060906 E037E170302300001 BIB 11 23 E170302300002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170302300003 PART-DET (T,P) E170302300004 EN-SEC - ANG1 is polar angle between beam and triton in E170302300005 laboratory system E170302300006 - ANG2-CM is polar angle between beam and proton in E170302300007 center of mass system E170302300008 (E-EXC,7-N-12) E170302300009 (E-LVL,6-C-11) E170302300010 INC-SOURCE Beam intensity is less than 3 nA. E170302300011 SAMPLE Target-thickness is 2.0 mg/cm**2. E170302300012 METHOD (COINC) Detect triton and proton in coincidence. E170302300013 DETECTOR - Solid angle: 3% of 4pi E170302300014 - Detector resolution is 350 to 450 keV.(for Si(Li) E170302300015 solid-state detector) E170302300016 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170302300017 [M.Fujiwara et al., Proceedings of the 5th E170302300018 French-Japanese Symposium on Nuclear Physics, E170302300019 Dogashima, Japan, 1989, p.348]. E170302300020 (SILI) To measure decay protons E170302300021 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170302300022 ADD-RES (COMP) Legendre polynomials analysis E170302300023 STATUS (CURVE) Data scanned from Fig.12, p3161 in reference E170302300024 HISTORY (20060627A) At. Re-digitized E170302300025 ENDBIB 23 0 E170302300026 COMMON 6 3 E170302300027 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E-LVL E170302300028 MEV ADEG MEV MEV MEV MEV E170302300029 450. 0. 11.0 13.0 4.3 4.8 E170302300030 ENDCOMMON 3 0 E170302300031 DATA 3 6 E170302300032 ANG2-CM DATA DATA-ERR E170302300033 ADEG MUB/SR2 MUB/SR2 E170302300034 1.128E+02 3.250E+01 2.317E+00 E170302300035 1.227E+02 3.578E+01 5.232E-01 E170302300036 1.324E+02 3.586E+01 2.018E+00 E170302300037 1.420E+02 3.713E+01 2.915E+00 E170302300038 1.516E+02 4.191E+01 1.868E+00 E170302300039 1.612E+02 3.915E+01 1.868E+00 E170302300040 ENDDATA 8 0 E170302300041 ENDSUBENT 40 0 E170302399999 SUBENT E1703024 20060906 E037E170302400001 BIB 11 23 E170302400002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170302400003 PART-DET (T,P) E170302400004 EN-SEC - ANG1 is polar angle between beam and triton in E170302400005 laboratory system E170302400006 - ANG2-CM is polar angle between beam and proton in E170302400007 center of mass system E170302400008 (E-EXC,7-N-12) E170302400009 (E-LVL,6-C-11) E170302400010 INC-SOURCE Beam intensity is less than 3 nA. E170302400011 SAMPLE Target-thickness is 2.0 mg/cm**2. E170302400012 METHOD (COINC) Detect triton and proton in coincidence. E170302400013 DETECTOR - Solid angle: 3% of 4pi E170302400014 - Detector resolution is 350 to 450 keV.(for Si(Li) E170302400015 solid-state detector) E170302400016 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170302400017 [M.Fujiwara et al., Proceedings of the 5th E170302400018 French-Japanese Symposium on Nuclear Physics, E170302400019 Dogashima, Japan, 1989, p.348]. E170302400020 (SILI) To measure decay protons E170302400021 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170302400022 ADD-RES (COMP) Legendre polynomials analysis E170302400023 STATUS (CURVE) Data scanned from Fig.12, p3161 in reference E170302400024 HISTORY (20060627A) At. Re-digitized E170302400025 ENDBIB 23 0 E170302400026 COMMON 6 3 E170302400027 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E-LVL E170302400028 MEV ADEG MEV MEV MEV MEV E170302400029 450. 0. 13.0 15.0 4.3 4.8 E170302400030 ENDCOMMON 3 0 E170302400031 DATA 3 6 E170302400032 ANG2-CM DATA DATA-ERR E170302400033 ADEG MUB/SR2 MUB/SR2 E170302400034 1.127E+02 3.070E+01 1.196E+00 E170302400035 1.223E+02 3.287E+01 1.495E+00 E170302400036 1.321E+02 3.724E+01 1.269E+00 E170302400037 1.417E+02 4.194E+01 2.015E+00 E170302400038 1.515E+02 3.836E+01 7.463E-01 E170302400039 1.610E+02 4.276E+01 1.642E+00 E170302400040 ENDDATA 8 0 E170302400041 ENDSUBENT 40 0 E170302499999 SUBENT E1703025 20060906 E037E170302500001 BIB 11 23 E170302500002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170302500003 PART-DET (T,P) E170302500004 EN-SEC - ANG1 is polar angle between beam and triton in E170302500005 laboratory system E170302500006 - ANG2-CM is polar angle between beam and proton in E170302500007 center of mass system E170302500008 (E-EXC,7-N-12) E170302500009 (E-LVL,6-C-11) E170302500010 INC-SOURCE Beam intensity is less than 3 nA. E170302500011 SAMPLE Target-thickness is 2.0 mg/cm**2. E170302500012 METHOD (COINC) Detect triton and proton in coincidence. E170302500013 DETECTOR - Solid angle: 3% of 4pi E170302500014 - Detector resolution is 350 to 450 keV.(for Si(Li) E170302500015 solid-state detector) E170302500016 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170302500017 [M.Fujiwara et al., Proceedings of the 5th E170302500018 French-Japanese Symposium on Nuclear Physics, E170302500019 Dogashima, Japan, 1989, p.348]. E170302500020 (SILI) To measure decay protons E170302500021 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170302500022 ADD-RES (COMP) Legendre polynomials analysis E170302500023 STATUS (CURVE) Data scanned from Fig.12, p3161 in reference E170302500024 HISTORY (20060627A) At. Re-digitized E170302500025 ENDBIB 23 0 E170302500026 COMMON 6 3 E170302500027 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E-LVL E170302500028 MEV ADEG MEV MEV MEV MEV E170302500029 450. 0. 15.0 20.0 4.3 4.8 E170302500030 ENDCOMMON 3 0 E170302500031 DATA 3 6 E170302500032 ANG2-CM DATA DATA-ERR E170302500033 ADEG MUB/SR2 MUB/SR2 E170302500034 1.125E+02 5.528E+01 2.511E+00 E170302500035 1.223E+02 5.803E+01 4.544E+00 E170302500036 1.321E+02 6.138E+01 2.631E+00 E170302500037 1.417E+02 6.628E+01 2.870E+00 E170302500038 1.513E+02 6.999E+01 1.913E+00 E170302500039 1.609E+02 6.006E+01 2.631E+00 E170302500040 ENDDATA 8 0 E170302500041 ENDSUBENT 40 0 E170302599999 SUBENT E1703026 20060906 E037E170302600001 BIB 11 23 E170302600002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170302600003 PART-DET (T,P) E170302600004 EN-SEC - ANG1 is polar angle between beam and triton in E170302600005 laboratory system E170302600006 - ANG2-CM is polar angle between beam and proton in E170302600007 center of mass system E170302600008 (E-EXC,7-N-12) E170302600009 (E-LVL,6-C-11) E170302600010 INC-SOURCE Beam intensity is less than 3 nA. E170302600011 SAMPLE Target-thickness is 2.0 mg/cm**2. E170302600012 METHOD (COINC) Detect triton and proton in coincidence. E170302600013 DETECTOR - Solid angle: 3% of 4pi E170302600014 - Detector resolution is 350 to 450 keV.(for Si(Li) E170302600015 solid-state detector) E170302600016 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170302600017 [M.Fujiwara et al., Proceedings of the 5th E170302600018 French-Japanese Symposium on Nuclear Physics, E170302600019 Dogashima, Japan, 1989, p.348]. E170302600020 (SILI) To measure decay protons E170302600021 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170302600022 ADD-RES (COMP) Legendre polynomials analysis E170302600023 STATUS (CURVE) Data scanned from Fig.12, p3161 in reference E170302600024 HISTORY (20060627A) At. Re-digitized E170302600025 ENDBIB 23 0 E170302600026 COMMON 6 3 E170302600027 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E-LVL E170302600028 MEV ADEG MEV MEV MEV MEV E170302600029 450. 0. 20.0 25.0 4.3 4.8 E170302600030 ENDCOMMON 3 0 E170302600031 DATA 3 6 E170302600032 ANG2-CM DATA DATA-ERR E170302600033 ADEG MUB/SR2 MUB/SR2 E170302600034 1.126E+02 2.994E+01 1.123E+00 E170302600035 1.222E+02 2.765E+01 7.474E-01 E170302600036 1.320E+02 2.489E+01 1.121E+00 E170302600037 1.417E+02 2.354E+01 8.221E-01 E170302600038 1.513E+02 2.635E+01 1.871E+00 E170302600039 1.609E+02 2.507E+01 2.769E+00 E170302600040 ENDDATA 8 0 E170302600041 ENDSUBENT 40 0 E170302699999 SUBENT E1703027 20060906 E037E170302700001 BIB 11 23 E170302700002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170302700003 PART-DET (T,P) E170302700004 EN-SEC - ANG1 is polar angle between beam and triton in E170302700005 laboratory system E170302700006 - ANG2-CM is polar angle between beam and proton in E170302700007 center of mass system E170302700008 (E-EXC,7-N-12) E170302700009 (E-LVL,6-C-11) E170302700010 INC-SOURCE Beam intensity is less than 3 nA. E170302700011 SAMPLE Target-thickness is 2.0 mg/cm**2. E170302700012 METHOD (COINC) Detect triton and proton in coincidence. E170302700013 DETECTOR - Solid angle: 3% of 4pi E170302700014 - Detector resolution is 350 to 450 keV.(for Si(Li) E170302700015 solid-state detector) E170302700016 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170302700017 [M.Fujiwara et al., Proceedings of the 5th E170302700018 French-Japanese Symposium on Nuclear Physics, E170302700019 Dogashima, Japan, 1989, p.348]. E170302700020 (SILI) To measure decay protons E170302700021 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170302700022 ADD-RES (COMP) Legendre polynomials analysis E170302700023 STATUS (CURVE) Data scanned from Fig.13, p3161 in reference E170302700024 HISTORY (20060627A) At. Re-digitized E170302700025 ENDBIB 23 0 E170302700026 COMMON 5 3 E170302700027 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170302700028 MEV ADEG MEV MEV MEV E170302700029 450. 0. 13.0 15.0 6.3 E170302700030 ENDCOMMON 3 0 E170302700031 DATA 3 6 E170302700032 ANG2-CM DATA DATA-ERR E170302700033 ADEG MUB/SR2 MUB/SR2 E170302700034 1.129E+02 1.571E+01 3.264E+00 E170302700035 1.226E+02 9.178E+00 3.264E+00 E170302700036 1.323E+02 1.148E+01 2.688E+00 E170302700037 1.420E+02 9.908E+00 1.037E+00 E170302700038 1.516E+02 1.041E+01 9.985E-01 E170302700039 1.611E+02 6.874E+00 5.031E+00 E170302700040 ENDDATA 8 0 E170302700041 ENDSUBENT 40 0 E170302799999 SUBENT E1703028 20060906 E037E170302800001 BIB 11 23 E170302800002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170302800003 PART-DET (T,P) E170302800004 EN-SEC - ANG1 is polar angle between beam and triton in E170302800005 laboratory system E170302800006 - ANG2-CM is polar angle between beam and proton in E170302800007 center of mass system E170302800008 (E-EXC,7-N-12) E170302800009 (E-LVL,6-C-11) E170302800010 INC-SOURCE Beam intensity is less than 3 nA. E170302800011 SAMPLE Target-thickness is 2.0 mg/cm**2. E170302800012 METHOD (COINC) Detect triton and proton in coincidence. E170302800013 DETECTOR - Solid angle: 3% of 4pi E170302800014 - Detector resolution is 350 to 450 keV.(for Si(Li) E170302800015 solid-state detector) E170302800016 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170302800017 [M.Fujiwara et al., Proceedings of the 5th E170302800018 French-Japanese Symposium on Nuclear Physics, E170302800019 Dogashima, Japan, 1989, p.348]. E170302800020 (SILI) To measure decay protons E170302800021 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170302800022 ADD-RES (COMP) Legendre polynomials analysis E170302800023 STATUS (CURVE) Data scanned from Fig.13, p3161 in reference E170302800024 HISTORY (20060627A) At. Re-digitized E170302800025 ENDBIB 23 0 E170302800026 COMMON 5 3 E170302800027 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170302800028 MEV ADEG MEV MEV MEV E170302800029 450. 0. 15.0 20.0 6.3 E170302800030 ENDCOMMON 3 0 E170302800031 DATA 3 6 E170302800032 ANG2-CM DATA DATA-ERR E170302800033 ADEG MUB/SR2 MUB/SR2 E170302800034 1.132E+02 2.104E+01 9.293E+00 E170302800035 1.227E+02 2.419E+01 1.221E+01 E170302800036 1.325E+02 2.442E+01 8.065E+00 E170302800037 1.421E+02 2.458E+01 6.759E+00 E170302800038 1.517E+02 2.366E+01 1.221E+01 E170302800039 1.611E+02 2.888E+01 6.144E+00 E170302800040 ENDDATA 8 0 E170302800041 ENDSUBENT 40 0 E170302899999 SUBENT E1703029 20060906 E037E170302900001 BIB 11 23 E170302900002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170302900003 PART-DET (T,P) E170302900004 EN-SEC - ANG1 is polar angle between beam and triton in E170302900005 laboratory system E170302900006 - ANG2-CM is polar angle between beam and proton in E170302900007 center of mass system E170302900008 (E-EXC,7-N-12) E170302900009 (E-LVL,6-C-11) E170302900010 INC-SOURCE Beam intensity is less than 3 nA. E170302900011 SAMPLE Target-thickness is 2.0 mg/cm**2. E170302900012 METHOD (COINC) Detect triton and proton in coincidence. E170302900013 DETECTOR - Solid angle: 3% of 4pi E170302900014 - Detector resolution is 350 to 450 keV.(for Si(Li) E170302900015 solid-state detector) E170302900016 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170302900017 [M.Fujiwara et al., Proceedings of the 5th E170302900018 French-Japanese Symposium on Nuclear Physics, E170302900019 Dogashima, Japan, 1989, p.348]. E170302900020 (SILI) To measure decay protons E170302900021 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170302900022 ADD-RES (COMP) Legendre polynomials analysis E170302900023 STATUS (CURVE) Data scanned from Fig.13, p3161 in reference E170302900024 HISTORY (20060627A) At. Re-digitized E170302900025 ENDBIB 23 0 E170302900026 COMMON 5 3 E170302900027 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170302900028 MEV ADEG MEV MEV MEV E170302900029 450. 0. 20.0 25.0 6.3 E170302900030 ENDCOMMON 3 0 E170302900031 DATA 3 6 E170302900032 ANG2-CM DATA DATA-ERR E170302900033 ADEG MUB/SR2 MUB/SR2 E170302900034 1.131E+02 1.158E+01 2.186E+00 E170302900035 1.226E+02 8.934E+00 7.285E-01 E170302900036 1.323E+02 1.173E+01 1.534E+00 E170302900037 1.418E+02 1.089E+01 8.052E-01 E170302900038 1.516E+02 1.392E+01 8.819E-01 E170302900039 1.609E+02 9.893E+00 8.052E-01 E170302900040 ENDDATA 8 0 E170302900041 ENDSUBENT 40 0 E170302999999 SUBENT E1703030 20060906 E037E170303000001 BIB 11 23 E170303000002 REACTION (6-C-12(HE3,T+P)6-C-11,SEQ/PAR,DA/DA,P/T) E170303000003 PART-DET (T,P) E170303000004 EN-SEC - ANG1 is polar angle between beam and triton in E170303000005 laboratory system E170303000006 - ANG2-CM is polar angle between beam and proton in E170303000007 center of mass system E170303000008 (E-EXC,7-N-12) E170303000009 (E-LVL,6-C-11) E170303000010 INC-SOURCE Beam intensity is less than 3 nA. E170303000011 SAMPLE Target-thickness is 2.0 mg/cm**2. E170303000012 METHOD (COINC) Detect triton and proton in coincidence. E170303000013 DETECTOR - Solid angle: 3% of 4pi E170303000014 - Detector resolution is 350 to 450 keV.(for Si(Li) E170303000015 solid-state detector) E170303000016 (MAGSP) GRAND RAIDEN to detect triton. See, e.g., E170303000017 [M.Fujiwara et al., Proceedings of the 5th E170303000018 French-Japanese Symposium on Nuclear Physics, E170303000019 Dogashima, Japan, 1989, p.348]. E170303000020 (SILI) To measure decay protons E170303000021 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E170303000022 ADD-RES (COMP) Legendre polynomials analysis E170303000023 STATUS (CURVE) Data scanned from Fig.13, p3161 in reference E170303000024 HISTORY (20060627A) At. Re-digitized E170303000025 ENDBIB 23 0 E170303000026 COMMON 5 3 E170303000027 EN ANG1 E-EXC-MIN E-EXC-MAX E-LVL E170303000028 MEV ADEG MEV MEV MEV E170303000029 450. 0. 13.0 15.0 8.1 E170303000030 ENDCOMMON 3 0 E170303000031 DATA 3 6 E170303000032 ANG2-CM DATA DATA-ERR E170303000033 ADEG MUB/SR2 MUB/SR2 E170303000034 1.137E+02 1.697E+01 5.329E+00 E170303000035 1.234E+02 2.009E+01 5.268E+00 E170303000036 1.330E+02 2.236E+01 2.450E+00 E170303000037 1.423E+02 2.021E+01 1.225E+00 E170303000038 1.520E+02 2.303E+01 1.654E+00 E170303000039 1.612E+02 2.193E+01 2.205E+00 E170303000040 ENDDATA 8 0 E170303000041 ENDSUBENT 40 0 E170303099999 NOSUBENT E1703031 20021015 0000E170303100001 NOSUBENT E1703032 20021015 0000E170303200001 NOSUBENT E1703033 20021015 0000E170303300001 NOSUBENT E1703034 20021015 0000E170303400001 NOSUBENT E1703035 20021015 0000E170303500001 ENDENTRY 35 0 E170399999999