ENTRY E1782 20121010 E071E178200000001 SUBENT E1782001 20121010 E071E178200100001 BIB 10 54 E178200100002 TITLE Large collectivity of 34Mg E178200100003 AUTHOR (H.Iwasaki, T.Motobayashi, H.Sakurai, K.Yoneda, T.Gomi,E178200100004 N.Aoi, N.Fukuda, Zs.Fulop, U.Futakami, Z.Gacsi, E178200100005 Y.Higurashi, N.Imai, N.Iwasa, T.Kubo, M.Kunibu, E178200100006 M.Kurokawa, Z.Liu, T.Minemura, A.Saito, M.Serata, E178200100007 S.Shimoura, S.Takeuchi, Y.X.Watanabe, K.Yamada, E178200100008 Y.Yanagisawa, M.Ishihara) E178200100009 INSTITUTE (2JPNTOK) Center for Nuclear Study (CNS) E178200100010 (2JPNYOK) Department of Physics E178200100011 (2JPNTOK) Department of Physics E178200100012 (2JPNIPC) E178200100013 (3HUNDEB) E178200100014 (2JPNTOH) Department of Physics E178200100015 (3CPRIMP) E178200100016 REFERENCE (J,PL/B,522,(3-4),227,200112) E178200100017 SAMPLE - Target enrichment is unknown. E178200100018 - Chemical-form of target is element. E178200100019 - Physical-form of target is solid. E178200100020 METHOD (EDE) Isotopic identification of the scattered E178200100021 particles E178200100022 FACILITY (CYCLO,2JPNIPC) To accelerate 40Ar primary beam on 9Be E178200100023 target E178200100024 (PRJFS,2JPNIPC) RIPS facility [T. Kubo et al., Nucl. E178200100025 Instrum. Methods B70(1992)309]] E178200100026 DETECTOR (TELES) To identify scattered particle, consists of 4 E178200100027 layers of ionimplanted silicon detectors, E178200100028 covered laboratory angles up to 6.0 degrees, E178200100029 efficiency is around 90% at laboratory E178200100030 scattering angles of less than 3.0 degrees, E178200100031 while it gradually decreases to about 30% at E178200100032 6.0 degrees. E178200100033 (NAICR) To measure de-excitation gamma-rays energy E178200100034 (resolution was typically 9.1% (FWHM) for the E178200100035 662 keV gamma-ray as measured with the 137Cs E178200100036 source), Around 90% at laboratory scattering E178200100037 angles of less than 3.0 degrees, while it E178200100038 gradually decreases to about 30% at 6.0 E178200100039 degrees. The total photo-peak efficiency was E178200100040 calculated to be 23.9% for a 656 keV gamma-ray E178200100041 emitted from a 34Mg nucleus in flight. The E178200100042 energy and efficiency calibrations of each E178200100043 NaI(Tl) detector were made by using standard E178200100044 22Na, 60Co, 88Y, and 137Cs sources. E178200100045 (SCIN) E178200100046 ADD-RES E1782.003:82-PB-0(12-MG-34,INL)82-PB-0 E178200100047 Deformation parameter E178200100048 See NRDF D1782 DATA,2 for detail. E178200100049 E1782.004:82-PB-0(12-MG-34,INL)82-PB-0 E178200100050 Transition strength (B(E2)) E178200100051 See NRDF D1782 DATA,3 for detail. E178200100052 E1782.006:82-PB-0(12-MG-32,INL)82-PB-0 E178200100053 Transition strength (B(E2)) E178200100054 See NRDF D1782 DATA,5 for detail. E178200100055 HISTORY (20040316C) Am + Sk E178200100056 ENDBIB 54 0 E178200100057 COMMON 1 3 E178200100058 E-RSL E178200100059 PER-CENT E178200100060 9.1 E178200100061 ENDCOMMON 3 0 E178200100062 ENDSUBENT 61 0 E178200199999 SUBENT E1782002 20061121 E039E178200200001 BIB 10 15 E178200200002 REACTION (82-PB-0(12-MG-34,INL)82-PB-0,PAR,IPA,,RAW) E178200200003 Raw data (include the contribution of efficiency) E178200200004 PART-DET (G,12-MG-34) E178200200005 EN-SEC ANG is polar angle between beam and 34Mg in laboratory E178200200006 system E178200200007 (E-LVL,12-MG-34) E178200200008 LEVEL-PROP (12-MG-34,E-LVL=0.656,SPIN=2.,PARITY=+1.) E178200200009 INC-SOURCE Beam intensity: Typical intensity of 4 counts per E178200200010 second E178200200011 SAMPLE Target-thickness is 693 mg/cm**2. E178200200012 METHOD (COINC) Detect 34Mg and prompt gamma in coincidence. E178200200013 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E178200200014 STATUS (TABLE) Data taken from the sentence, p229 in E178200200015 reference E178200200016 HISTORY (20061017A) On. IPA moved from SF8 to SF6 E178200200017 ENDBIB 15 0 E178200200018 COMMON 3 3 E178200200019 ANG-MAX E-LVL E-LVL-ERR E178200200020 ADEG KEV KEV E178200200021 6.0 656. 7. E178200200022 ENDCOMMON 3 0 E178200200023 DATA 3 1 E178200200024 EN DATA DATA-ERR E178200200025 MEV/A MB MB E178200200026 44.9 286. 52. E178200200027 ENDDATA 3 0 E178200200028 ENDSUBENT 27 0 E178200299999 NOSUBENT E1782003 20040622 0000E178200300001 NOSUBENT E1782004 20040622 0000E178200400001 SUBENT E1782005 20121010 E071E178200500001 BIB 9 12 E178200500002 REACTION (82-PB-0(12-MG-32,INL)82-PB-0,PAR,IPA,,RAW) E178200500003 Raw data (include the contribution of efficiency) E178200500004 PART-DET (G,12-MG-32) E178200500005 EN-SEC ANG is polar angle (lab.) between beam and 32Mg E178200500006 (E-LVL,12-MG-32) E178200500007 LEVEL-PROP (12-MG-32,E-LVL=0.886,SPIN=2.,PARITY=+1.) E178200500008 SAMPLE Target-thickness is 573 mg/cm**2. E178200500009 METHOD (COINC) Detect 32Mg and prompt gamma in coincidence. E178200500010 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E178200500011 STATUS (TABLE) Taken from the sentence, p230 in reference E178200500012 HISTORY (20061017A) On. IPA moved from SF8 to SF6 E178200500013 (20120727A) Nf. Unit corrected: E-LVL, MEV -> KEV E178200500014 ENDBIB 12 0 E178200500015 COMMON 2 3 E178200500016 ANG-MAX E-LVL E178200500017 ADEG KEV E178200500018 6. 886. E178200500019 ENDCOMMON 3 0 E178200500020 DATA 3 1 E178200500021 EN DATA DATA-ERR E178200500022 MEV/A MB MB E178200500023 44.0 217. 23. E178200500024 ENDDATA 3 0 E178200500025 ENDSUBENT 24 0 E178200599999 NOSUBENT E1782006 20040622 0000E178200600001 SUBENT E1782007 20061121 E039E178200700001 BIB 9 13 E178200700002 REACTION (6-C-0(12-MG-34,INL)6-C-0,PAR,IPA,,RAW) E178200700003 Raw data (include the contribution of efficiency) E178200700004 PART-DET (G,12-MG-34) E178200700005 EN-SEC ANG is polar angle between beam and 34Mg in laboratory E178200700006 system E178200700007 (E-LVL,12-MG-34) E178200700008 LEVEL-PROP (12-MG-34,E-LVL=0.656,SPIN=2.,PARITY=+1.) E178200700009 SAMPLE Target-thickness is 339 mg/cm**2. E178200700010 METHOD (COINC) Detect 34Mg and prompt gamma in coincidence. E178200700011 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E178200700012 STATUS (TABLE) Data taken from the sentence, p230 in E178200700013 reference E178200700014 HISTORY (20061017A) On. IPA moved from SF8 to SF6 E178200700015 ENDBIB 13 0 E178200700016 COMMON 3 3 E178200700017 ANG-MAX E-LVL E-LVL-ERR E178200700018 ADEG KEV MEV E178200700019 6. 656. 7. E178200700020 ENDCOMMON 3 0 E178200700021 DATA 3 1 E178200700022 EN DATA DATA-ERR E178200700023 MEV/A MB MB E178200700024 44.9 40. 12. E178200700025 ENDDATA 3 0 E178200700026 ENDSUBENT 25 0 E178200799999 ENDENTRY 7 0 E178299999999