ENTRY E1787 20130605 E075E178700000001 SUBENT E1787001 20130605 E075E178700100001 BIB 13 34 E178700100002 TITLE Measurement of proton-induced helium production cross E178700100003 sections for aluminum and nickel below 16 MeV E178700100004 AUTHOR (Y.Takao, Y.Kanda, H.Hashimoto, K.Yamasaki, E178700100005 K.Yamaguchi, T.Yonemoto, M.Miwa, H.Etoh, K.Nagae) E178700100006 INSTITUTE (2JPNKYU) Department of Energy Conversion Engineering E178700100007 REFERENCE (J,NST,34,(2),109,199702) Main reference E178700100008 Main reference. See also TITLE and AUTHOR. E178700100009 (R,JAERI-C-96-008,165,1996) E178700100010 Y.Takao+, Preliminary report E178700100011 (J,RSI,67,198,1996) E178700100012 Y.Takao+, Helium atoms measurement system (HAMS) E178700100013 PART-DET (A) E178700100014 MISC-COL (MISC) Primary proton energy E178700100015 INC-SOURCE Beam intensity is less than 0.1 micro-Ampere. E178700100016 SAMPLE - Chemical-form of target is element. Chemical E178700100017 purities are 99.999%, 99.98% and 99.99% for Al, Ni E178700100018 and Au samples respectively. E178700100019 - Physical-form of target: Sample table was cooled by E178700100020 liquid nitrogen to keep the temperature of the E178700100021 sample stacks below 223K, so as not to release the E178700100022 produced He in the stacks during the proton E178700100023 irradiation E178700100024 - Target-thickness: Sample sizes are 12x9x0.095 mm**3, E178700100025 12x9x0.119 mm**3, 12x9x0.051 mm**3 for Al, Ni and Au E178700100026 samples, respectively. E178700100027 FACILITY (VDGT,2JPNKYU) Tandem Accelerator Laboratory E178700100028 COMMENT He-4 (not He) cross section is given. He-3 is used as E178700100029 standard for calibration (T.Fukahori, 2013-03-13) E178700100030 REL-REF (M,,Y.Takao+,J,RSI,67,198,1996) E178700100031 Description about Helium Atoms Measurement System HAMS E178700100032 STATUS (UNOBT) No reply to requests for data on 2003.02.08. E178700100033 HISTORY (20030207C) E178700100034 (20130412A) MA: COMMENT and REL-REF added and typos E178700100035 modified. E178700100036 ENDBIB 34 0 E178700100037 NOCOMMON 0 0 E178700100038 ENDSUBENT 37 0 E178700199999 SUBENT E1787002 20130605 E075E178700200001 BIB 6 15 E178700200002 REACTION (13-AL-27(P,X)2-HE-4,,SIG) E178700200003 INC-SPECT EN: Proton energy in samples were determined on the E178700200004 basis of estimations by using energy loss data for the E178700200005 materials [H.H.Andersen and J.F.Ziegler, Hydrogen E178700200006 Stopping Powers and Ranges in All Elements, Pergamon E178700200007 Press, New York (1977)]. E178700200008 METHOD (SITA) E178700200009 (HE-AC) Alpha particles emitted from sample are E178700200010 stopped in Au catchers. E178700200011 (MASSP) Released gas from solid-sample in furnace is E178700200012 analyzed by quadrupole-type mass spectrometer. E178700200013 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E178700200014 FLAG (1.) Measured by sample-lamination experiment E178700200015 (2.) Measured by sample-catcher-lamination experiment E178700200016 STATUS (TABLE) Taken from Table 2, p113 in reference E178700200017 ENDBIB 15 0 E178700200018 NOCOMMON 0 0 E178700200019 DATA 6 12 E178700200020 EN-MIN EN-MAX DATA DATA-ERR MISC FLAG E178700200021 MEV MEV MB MB MEV NO-DIM E178700200022 1.6 4.0 18.0 2.0 18.4 1.0E178700200023 4.0 5.6 82.0 4.0 18.4 1.0E178700200024 5.6 6.9 115.0 5.0 8.9 2.0E178700200025 7.0 8.2 124.0 5.0 10.0 2.0E178700200026 8.2 9.2 129.0 6.0 10.9 2.0E178700200027 9.5 10.4 121.0 5.0 12.0 2.0E178700200028 10.7 11.5 121.0 5.0 13.0 2.0E178700200029 11.8 12.6 121.0 5.0 14.0 2.0E178700200030 12.8 13.5 124.0 5.0 14.9 2.0E178700200031 13.7 14.4 125.0 6.0 15.7 2.0E178700200032 14.6 15.2 133.0 6.0 16.5 2.0E178700200033 15.7 16.3 146.0 6.0 17.5 2.0E178700200034 ENDDATA 14 0 E178700200035 ENDSUBENT 34 0 E178700299999 SUBENT E1787003 20130605 E075E178700300001 BIB 6 15 E178700300002 REACTION (28-NI-0(P,X)2-HE-4,,SIG) E178700300003 INC-SPECT EN: Proton energy in samples were determined on the E178700300004 basis of estimations by using energy loss data for the E178700300005 materials [H.H.Andersen and J.F.Ziegler, Hydrogen E178700300006 Stopping Powers and Ranges in All Elements, Pergamon E178700300007 Press, New York (1977)]. E178700300008 SAMPLE Target is natural. E178700300009 METHOD (STTA) Al sample is sandwiched by the two Au catchers E178700300010 (sample-catcher-lamination experiment). E178700300011 (HE-AC) Alpha particles emitted from sample are E178700300012 stopped in Au catchers. E178700300013 (MASSP) Released gas from solid-sample in furnace is E178700300014 analyzed by quadrupole-type mass spectrometer. E178700300015 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E178700300016 STATUS (TABLE) Taken from Table 3, p114 in reference E178700300017 ENDBIB 15 0 E178700300018 NOCOMMON 0 0 E178700300019 DATA 6 9 E178700300020 EN-MIN EN-MAX DATA +DATA-ERR -DATA-ERR MISC E178700300021 MEV MEV MB MB MB MEV E178700300022 0.4 6.7 0.0 8.8E178700300023 4.6 8.7 1.0 2. 1. 10.5E178700300024 6.4 9.9 4.0 2. 2. 11.6E178700300025 7.9 11.0 13.0 2. 2. 12.6E178700300026 9.2 12.1 26.0 2. 2. 13.6E178700300027 10.4 13.1 30.0 2. 2. 14.5E178700300028 11.4 13.9 39.0 2. 2. 15.3E178700300029 12.4 14.8 41.0 2. 2. 16.1E178700300030 14.0 16.3 52.0 3. 3. 17.5E178700300031 ENDDATA 11 0 E178700300032 ENDSUBENT 31 0 E178700399999 ENDENTRY 3 0 E178799999999