ENTRY E2464 20150624 E097E246400000001 SUBENT E2464001 20150624 E097E246400100001 BIB 11 18 E246400100002 TITLE Production of 28Mg by triton and alpha-particle E246400100003 induced reactions E246400100004 AUTHOR (T.Nozaki, M.Furukawa, S.Kume, R.Seki) E246400100005 INSTITUTE (2JPNIPC) E246400100006 REFERENCE (J,ARI,26,17,1975) E246400100007 SAMPLE - Target is natural. E246400100008 - Chemical-form of target is element. E246400100009 - Physical-form of target is solid. E246400100010 METHOD (STTA,GSPEC) E246400100011 (BCINT) E246400100012 FACILITY (CYCLO,2JPNIPC) E246400100013 DETECTOR (GELI) 20 ml E246400100014 (NAICR) 7.5 x 7.5 cm cylindrical or 4.4 x 5.0 cm well E246400100015 type E246400100016 ERR-ANALYS (DATA-ERR) mainly due to possible errors in the E246400100017 beam-current measurement E246400100018 ADD-RES (TTY-C) E246400100019 HISTORY (20141110C) Ichiko E246400100020 ENDBIB 18 0 E246400100021 COMMON 1 3 E246400100022 DATA-ERR E246400100023 PER-CENT E246400100024 15. E246400100025 ENDCOMMON 3 0 E246400100026 ENDSUBENT 25 0 E246400199999 SUBENT E2464002 20150624 E097E246400200001 BIB 6 10 E246400200002 REACTION (12-MG-0(T,X)12-MG-28,,SIG) E246400200003 DECAY-DATA (12-MG-28,21.2HR,DG,30.6,0.95, E246400200004 DG,400.6,0.359, E246400200005 DG,941.7,0.359, E246400200006 DG,1342.2,0.54) E246400200007 INC-SOURCE Beam intensity is about 1 micro-Ampere. E246400200008 SAMPLE Target-thickness: 1 mg/cm2 (evaporated film on E246400200009 tantalum) and 20 mg/cm2 E246400200010 METHOD (ACTIV) irradiated for 5-30 min. E246400200011 STATUS (CURVE) Fig.1 of J,ARI,26,1975,17 E246400200012 ENDBIB 10 0 E246400200013 NOCOMMON 0 0 E246400200014 DATA 3 7 E246400200015 EN EN-ERR DATA E246400200016 MEV MEV MB E246400200017 2.56 3.93E+00 E246400200018 6.75 0.85 7.84E+00 E246400200019 9.60 6.73E+00 E246400200020 11.37 6.13E+00 E246400200021 13.59 3.93E+00 E246400200022 15.80 2.96E+00 E246400200023 18.79 2.46E+00 E246400200024 ENDDATA 9 0 E246400200025 ENDSUBENT 24 0 E246400299999 SUBENT E2464003 20150624 E097E246400300001 BIB 6 9 E246400300002 REACTION (13-AL-27(T,X)12-MG-28,,SIG) E246400300003 DECAY-DATA (12-MG-28,21.2HR,DG,30.6,0.95, E246400300004 DG,400.6,0.359, E246400300005 DG,941.7,0.359, E246400300006 DG,1342.2,0.54) E246400300007 INC-SOURCE Beam intensity is about 1 micro-Ampere. E246400300008 SAMPLE Target-thickness is 6 to 25 mg/cm2. E246400300009 METHOD (ACTIV) irradiated for 5-30 min. E246400300010 STATUS (CURVE) Fig.1 of J,ARI,26,1975,17 E246400300011 ENDBIB 9 0 E246400300012 NOCOMMON 0 0 E246400300013 DATA 3 12 E246400300014 EN EN-ERR DATA E246400300015 MEV MEV MB E246400300016 5.86 1.42 1.97E-01 E246400300017 8.37 6.36E-01 E246400300018 10.58 0.98 1.04E+00 E246400300019 12.45 1.60E+00 E246400300020 13.85 2.19E+00 E246400300021 15.80 2.96E+00 E246400300022 16.91 3.54E+00 E246400300023 18.12 3.95E+00 E246400300024 19.33 4.31E+00 E246400300025 20.45 4.45E+00 E246400300026 21.67 4.61E+00 E246400300027 22.62 4.35E+00 E246400300028 ENDDATA 14 0 E246400300029 ENDSUBENT 28 0 E246400399999 SUBENT E2464004 20150624 E097E246400400001 BIB 6 10 E246400400002 REACTION (12-MG-0(A,X)12-MG-28,,SIG) E246400400003 DECAY-DATA (12-MG-28,21.2HR,DG,30.6,0.95, E246400400004 DG,400.6,0.359, E246400400005 DG,941.7,0.359, E246400400006 DG,1342.2,0.54) E246400400007 INC-SOURCE Beam intensity is 0.5 to 3 micro-Ampere. E246400400008 SAMPLE Target-thickness: 1 mg/cm2 (evaporated film on E246400400009 tantalum) and 20 mg/cm2 E246400400010 METHOD (ACTIV) irradiated for 3-100 min. E246400400011 STATUS (CURVE) Fig.1 of J,ARI,26,1975,17 E246400400012 ENDBIB 10 0 E246400400013 NOCOMMON 0 0 E246400400014 DATA 3 9 E246400400015 EN EN-ERR DATA E246400400016 MEV MEV MB E246400400017 21.71 1.62 8.64E-03 E246400400018 22.53 7.74E-03 E246400400019 26.12 3.07E-02 E246400400020 27.78 4.91E-02 E246400400021 29.35 7.31E-02 E246400400022 32.33 1.35 1.35E-01 E246400400023 35.23 1.87E-01 E246400400024 37.90 2.02E-01 E246400400025 40.33 2.15E-01 E246400400026 ENDDATA 11 0 E246400400027 ENDSUBENT 26 0 E246400499999 SUBENT E2464005 20150624 E097E246400500001 BIB 6 9 E246400500002 REACTION (13-AL-27(A,X)12-MG-28,,SIG) E246400500003 DECAY-DATA (12-MG-28,21.2HR,DG,30.6,0.95, E246400500004 DG,400.6,0.359, E246400500005 DG,941.7,0.359, E246400500006 DG,1342.2,0.54) E246400500007 INC-SOURCE Beam intensity is 0.5 to 3 micro-Ampere. E246400500008 SAMPLE Target-thickness is 6 to 25 mg/cm2. E246400500009 METHOD (ACTIV) irradiated for 3-100 min. E246400500010 STATUS (CURVE) Fig.1 of J,ARI,26,1975,17 E246400500011 ENDBIB 9 0 E246400500012 NOCOMMON 0 0 E246400500013 DATA 3 10 E246400500014 EN EN-ERR DATA E246400500015 MEV MEV MB E246400500016 32.57 1.15 1.40E-03 E246400500017 34.76 6.23E-03 E246400500018 36.94 1.65E-02 E246400500019 38.01 2.03E-02 E246400500020 38.90 3.50E-02 E246400500021 39.58 3.40E-02 E246400500022 40.83 0.88 6.06E-02 E246400500023 41.05 5.03E-02 E246400500024 42.28 7.60E-02 E246400500025 43.61 1.06E-01 E246400500026 ENDDATA 12 0 E246400500027 ENDSUBENT 26 0 E246400599999 SUBENT E2464006 20150624 E097E246400600001 BIB 6 8 E246400600002 REACTION (12-MG-0(T,X)11-NA-24,,SIG) E246400600003 DECAY-DATA (11-NA-24,14.96HR,DG,1368.5,1., E246400600004 DG,2753.9,1.) E246400600005 INC-SOURCE Beam intensity is about 1 micro-Ampere. E246400600006 SAMPLE Target-thickness: 1 mg/cm2 (evaporated film on E246400600007 tantalum) and 20 mg/cm2 E246400600008 METHOD (ACTIV) irradiated for 5-30 min. E246400600009 STATUS (CURVE) Fig.2 of J,ARI,26,1975,17 E246400600010 ENDBIB 8 0 E246400600011 NOCOMMON 0 0 E246400600012 DATA 2 5 E246400600013 EN DATA E246400600014 MEV MB E246400600015 9.73 8.85E+00 E246400600016 11.00 1.14E+01 E246400600017 13.52 1.73E+01 E246400600018 15.98 2.14E+01 E246400600019 18.91 2.44E+01 E246400600020 ENDDATA 7 0 E246400600021 ENDSUBENT 20 0 E246400699999 SUBENT E2464007 20150624 E097E246400700001 BIB 6 7 E246400700002 REACTION (13-AL-27(T,X)11-NA-24,,SIG) E246400700003 DECAY-DATA (11-NA-24,14.96HR,DG,1368.5,1., E246400700004 DG,2753.9,1.) E246400700005 INC-SOURCE Beam intensity is about 1 micro-Ampere. E246400700006 SAMPLE Target-thickness is 6 to 25 mg/cm2. E246400700007 METHOD (ACTIV) irradiated for 5-30 min. E246400700008 STATUS (CURVE) Fig.2 of J,ARI,26,1975,17 E246400700009 ENDBIB 7 0 E246400700010 NOCOMMON 0 0 E246400700011 DATA 2 7 E246400700012 EN DATA E246400700013 MEV MB E246400700014 15.54 1.37E-01 E246400700015 17.00 4.33E-01 E246400700016 18.22 1.04E+00 E246400700017 19.38 2.25E+00 E246400700018 20.63 4.42E+00 E246400700019 21.75 7.51E+00 E246400700020 22.72 1.11E+01 E246400700021 ENDDATA 9 0 E246400700022 ENDSUBENT 21 0 E246400799999 SUBENT E2464008 20150624 E097E246400800001 BIB 6 8 E246400800002 REACTION (12-MG-0(A,X)11-NA-24,,SIG) E246400800003 DECAY-DATA (11-NA-24,14.96HR,DG,1368.5,1., E246400800004 DG,2753.9,1.) E246400800005 INC-SOURCE Beam intensity is 0.5 to 3 micro-Ampere. E246400800006 SAMPLE Target-thickness: 1 mg/cm2 (evaporated film on E246400800007 tantalum) and 20 mg/cm2 E246400800008 METHOD (ACTIV) irradiated for 3-100 min. E246400800009 STATUS (CURVE) Fig.2 of J,ARI,26,1975,17 E246400800010 ENDBIB 8 0 E246400800011 NOCOMMON 0 0 E246400800012 DATA 3 10 E246400800013 EN EN-ERR DATA E246400800014 MEV MEV MB E246400800015 21.85 1.60 4.07E-01 E246400800016 22.64 6.78E-01 E246400800017 25.04 2.73E+00 E246400800018 26.17 3.47E+00 E246400800019 27.99 5.24E+00 E246400800020 29.35 6.38E+00 E246400800021 32.26 1.36 8.02E+00 E246400800022 35.26 8.81E+00 E246400800023 37.86 9.29E+00 E246400800024 40.19 9.59E+00 E246400800025 ENDDATA 12 0 E246400800026 ENDSUBENT 25 0 E246400899999 ENDENTRY 8 0 E246499999999