ENTRY E2761 20240503 E276100000001 SUBENT E2761001 20240503 20240513 E276100100001 BIB 9 14 E276100100002 TITLE Measurement of the fragmentation of Carbon nuclei used E276100100003 in hadron-therapy E276100100004 AUTHOR (G.De Lellis, S.Buontempo, F.Di Capua, A.Di Crescenzo, E276100100005 P.Migliozzi, Y.Petukhov, C.Pistillo, A.Russo, E276100100006 P.Strolin, V.Tioukov, M.Durante , Y.Furusawa, E276100100007 T.Toshito, N.Yasuda, A.Ariga, N.Naganawa) E276100100008 INSTITUTE (2ITYNAP,2GERGSI,2GERTHD,2JPNIRS,2JPNNAG) E276100100009 REFERENCE (J,NP/A,853,124,2011) E276100100010 SAMPLE - Chemical-form of target: Polycarbonate (C16H14O3) E276100100011 - Physical-form of target is solid. E276100100012 FACILITY (SYNCH,2JPNIRS) HIMAC E276100100013 DETECTOR (PLATE) Emulsion Cloud Chamber (ECC) E276100100014 STATUS (TABLE,,G.De Lellis+,J,NP/A,853,124,2011) Eqs. (1)-(6) E276100100015 HISTORY (20231202C) S. W E276100100016 ENDBIB 14 0 E276100100017 COMMON 1 3 E276100100018 EN E276100100019 MEV/A E276100100020 400. E276100100021 ENDCOMMON 3 0 E276100100022 ENDSUBENT 21 0 E276100199999 SUBENT E2761002 20240503 20240513 E276100200001 BIB 2 4 E276100200002 REACTION (1-H-CXX(6-C-12,X)ELEM,,SIG) E276100200003 Cross section for polycarbonate (C16H14O3) E276100200004 ERR-ANALYS (ERR-SYS) Total systematic uncertainty E276100200005 (ERR-S) Statistical uncertainty E276100200006 ENDBIB 4 0 E276100200007 NOCOMMON 0 0 E276100200008 DATA 4 4 E276100200009 ELEMENT DATA ERR-S ERR-SYS E276100200010 NO-DIM MB MB MB E276100200011 5. 2510. 140. 250. E276100200012 4. 1170. 90. 120. E276100200013 3. 1460. 105. 150. E276100200014 2. 7510. 240. 750. E276100200015 ENDDATA 6 0 E276100200016 ENDSUBENT 15 0 E276100299999 SUBENT E2761003 20240503 20240513 E276100300001 BIB 2 4 E276100300002 REACTION (1-H-CXX(6-C-12,TCC),,SIG) E276100300003 Cross section for polycarbonate (C16H14O3) E276100300004 ERR-ANALYS (ERR-SYS) Total systematic uncertainty E276100300005 (ERR-S) Statistical uncertainty E276100300006 ENDBIB 4 0 E276100300007 NOCOMMON 0 0 E276100300008 DATA 3 1 E276100300009 DATA ERR-S ERR-SYS E276100300010 MB MB MB E276100300011 18420. 380. 1840. E276100300012 ENDDATA 3 0 E276100300013 ENDSUBENT 12 0 E276100399999 SUBENT E2761004 20240503 20240513 E276100400001 BIB 2 3 E276100400002 REACTION (1-H-CXX(6-C-12,X)4-BE-8,,SIG) E276100400003 Cross section for polycarbonate (C16H14O3) E276100400004 ERR-ANALYS (DATA-ERR) No information on source of uncertainties E276100400005 ENDBIB 3 0 E276100400006 NOCOMMON 0 0 E276100400007 DATA 2 1 E276100400008 DATA DATA-ERR E276100400009 MB MB E276100400010 190. 40. E276100400011 ENDDATA 3 0 E276100400012 ENDSUBENT 11 0 E276100499999 ENDENTRY 4 0 E276199999999