ENTRY F1179 20121005 F048F117900000001 SUBENT F1179001 20121005 F048F117900100001 BIB 10 29 F117900100002 TITLE Some (d,a) reactions on Be-9, F-19, and Al-27 at F117900100003 27.5 MeV. F117900100004 AUTHOR (S.Mayo,J.Testoni,O.M.Bilaniuk) F117900100005 INSTITUTE (3ARGCNE) F117900100006 REFERENCE (J,PR,133,(2),B350,1964) F117900100007 #doi:10.1103/PhysRev.133.B350 F117900100008 FACILITY (SYNCY,3ARGCNE)180-cm synchrocyclotron. F117900100009 DETECTOR (SOLST,SIBAR) A solid-state detecting system with a F117900100010 resolution in energy of about 1% was used. The solid F117900100011 angle of detection was 1.2*10-3 sr. The detector used F117900100012 was of a gold-silicon surface barrier type properly F117900100013 biased to keep its sensitive region thick enough for F117900100014 the total stopping of the detected alpha group. F117900100015 SAMPLE Thin foils of beryllium, Teflon, and aluminum were F117900100016 used. The targets were mounted on a frame at 45+-0.5 F117900100017 degr. to the beam direction. F117900100018 METHOD (BCINT) F117900100019 ERR-ANALYS (EN-ERR) Energy error F117900100020 (ERR-S,10.,25.) Statistical error F117900100021 (ERR-DIG) Data digitizing error F117900100022 (ANG-ERR-D) Angle digitizing error F117900100023 (DATA-ERR) Error from the graphic bars F117900100024 Bars indicate the absolute errors of differential crossF117900100025 sections due to statistics, background subtraction, F117900100026 target thickness, beam current integration, solid F117900100027 angle, and the instability of the system. F117900100028 Scattering angles were known with an accuracy F117900100029 of + - 1 degree. F117900100030 HISTORY (20121004C) F117900100031 ENDBIB 29 0 F117900100032 COMMON 2 3 F117900100033 EN EN-ERR F117900100034 MEV MEV F117900100035 27.5 0.1 F117900100036 ENDCOMMON 3 0 F117900100037 ENDSUBENT 36 0 F117900199999 SUBENT F1179002 20121005 F048F117900200001 BIB 3 5 F117900200002 REACTION (4-BE-9(D,A)3-LI-7,PAR,DA) F117900200003 SAMPLE Thin foil of beryllium was used, target thickness F117900200004 was 2.25+ - 0.10 mg/cm2. Beryllium target was of F117900200005 commercial grade, 99.5% pure. F117900200006 STATUS (CURVE) Fig.2 F117900200007 ENDBIB 5 0 F117900200008 COMMON 2 3 F117900200009 ANG-ERR-D ERR-DIG F117900200010 ADEG MB/SR F117900200011 0.317 0.0004 F117900200012 ENDCOMMON 3 0 F117900200013 DATA 4 30 F117900200014 E-LVL ANG-CM DATA-CM DATA-ERR F117900200015 MEV ADEG MB/SR MB/SR F117900200016 4.63 10.411 6.3553E-01 9.994E-02 F117900200017 4.63 16.845 5.7149E-01 1.0161E-01 F117900200018 4.63 23.845 4.0906E-01 7.166E-02 F117900200019 4.63 30.279 3.4502E-01 6.984E-02 F117900200020 4.63 36.557 3.2099E-01 5.831E-02 F117900200021 4.63 43.051 2.7028E-01 5.012E-02 F117900200022 4.63 49.381 2.5791E-01 5.167E-02 F117900200023 4.63 55.211 2.0893E-01 4.048E-02 F117900200024 4.63 61.295 2.1659E-01 3.664E-02 F117900200025 4.63 66.686 2.1933E-01 3.997E-02 F117900200026 4.63 73.023 2.0863E-01 4.168E-02 F117900200027 4.63 78.406 2.0970E-01 3.991E-02 F117900200028 4.63 84.080 2.0074E-01 3.995E-02 F117900200029 4.63 89.455 2.0015E-01 4.001E-02 F117900200030 4.63 94.875 2.0955E-01 3.985E-02 F117900200031 4.63 99.877 2.0066E-01 3.834E-02 F117900200032 7.47 20.648 1.00070 2.0105E-01 F117900200033 7.47 26.492 1.20650 2.0334E-01 F117900200034 7.47 33.830 8.0221E-01 1.9663E-01 F117900200035 7.47 40.648 5.0128E-01 1.0023E-01 F117900200036 7.47 47.103 4.2374E-01 8.665E-02 F117900200037 7.47 53.799 5.2950E-01 1.0273E-01 F117900200038 7.47 59.625 4.7204E-01 1.0019E-01 F117900200039 7.47 66.312 3.2113E-01 6.004E-02 F117900200040 7.47 72.465 2.6363E-01 4.655E-02 F117900200041 7.47 78.278 1.9618E-01 3.671E-02 F117900200042 7.47 83.851 1.9542E-01 4.013E-02 F117900200043 7.47 89.450 2.1466E-01 3.667E-02 F117900200044 7.47 94.742 2.5061E-01 5.382E-02 F117900200045 7.47 100.230 1.8320E-01 3.342E-02 F117900200046 ENDDATA 32 0 F117900200047 ENDSUBENT 46 0 F117900299999 SUBENT F1179003 20121005 F048F117900300001 BIB 3 4 F117900300002 REACTION (9-F-19(D,A)8-O-17,PAR,DA) F117900300003 SAMPLE Thin foil of Teflon was used. Target thickness was F117900300004 1.13+ - 0.04 mg/cm2. F117900300005 STATUS (CURVE) Fig.3 F117900300006 ENDBIB 4 0 F117900300007 COMMON 2 3 F117900300008 ANG-ERR-D ERR-DIG F117900300009 ADEG MB/SR F117900300010 0.359 0.0008 F117900300011 ENDCOMMON 3 0 F117900300012 DATA 4 35 F117900300013 E-LVL ANG-CM DATA-CM DATA-ERR F117900300014 MEV ADEG MB/SR MB/SR F117900300015 0. 16.814 1.9259E-01 3.354E-02 F117900300016 0. 22.554 1.4991E-01 2.257E-02 F117900300017 0. 28.110 1.369E-01 2.58E-02 F117900300018 0. 33.841 9.227E-02 1.548E-02 F117900300019 0. 39.336 6.701E-02 1.161E-02 F117900300020 0. 44.731 8.82E-02 1.355E-02 F117900300021 0. 50.036 9.132E-02 1.87E-02 F117900300022 0. 55.411 4.155E-02 5.16E-03 F117900300023 0. 60.655 3.241E-02 6.45E-03 F117900300024 0. 66.300 3.747E-02 7.1E-03 F117900300025 0. 71.561 3.156E-02 5.12E-03 F117900300026 0. 77.175 3.017E-02 6.45E-03 F117900300027 0. 82.416 2.039E-02 4.52E-03 F117900300028 0. 87.368 1.901E-02 5.36E-03 F117900300029 0. 92.661 1.955E-02 4.51E-03 F117900300030 0. 97.642 2.398E-02 4.56E-03 F117900300031 0. 102.57 1.808E-02 5.17E-03 F117900300032 0. 107.51 1.476E-02 3.22E-03 F117900300033 0. 117.77 1.586E-02 3.13E-03 F117900300034 0. 126.68 1.246E-02 3.28E-03 F117900300035 0.872 22.178 1.479E-02 4.07E-03 F117900300036 0.872 28.290 2.394E-02 9.93E-03 F117900300037 0.872 33.770 3.593E-02 7.87E-03 F117900300038 0.872 39.290 2.392E-02 5.93E-03 F117900300039 0.872 45.006 2.791E-02 5.8E-03 F117900300040 0.872 50.919 2.08E-02 8.11E-03 F117900300041 0.872 56.351 2.892E-02 6.06E-03 F117900300042 0.872 61.598 2.182E-02 4.9E-03 F117900300043 0.872 67.178 1.471E-02 3.09E-03 F117900300044 0.872 72.120 9.93E-03 1.6E-03 F117900300045 0.872 77.452 9.79E-03 1.9E-03 F117900300046 0.872 82.548 1.765E-02 3.93E-03 F117900300047 0.872 87.894 1.867E-02 3.99E-03 F117900300048 0.872 92.857 1.569E-02 3.74E-03 F117900300049 0.872 97.423 7.43E-03 9.1E-04 F117900300050 ENDDATA 37 0 F117900300051 ENDSUBENT 50 0 F117900399999 SUBENT F1179004 20121005 F048F117900400001 BIB 3 5 F117900400002 REACTION (13-AL-27(D,A)12-MG-25,PAR,DA) F117900400003 SAMPLE Thin foil of aluminum was used. Target thickness was F117900400004 0.28+ - 0.03 mg/cm2. Aluminum target was of F117900400005 commercial grade, 99.5% pure. F117900400006 STATUS (CURVE) Fig.4 F117900400007 ENDBIB 5 0 F117900400008 COMMON 2 3 F117900400009 ANG-ERR-D ERR-DIG F117900400010 ADEG MB/SR F117900400011 0.444 0.0005 F117900400012 ENDCOMMON 3 0 F117900400013 DATA 4 38 F117900400014 E-LVL ANG-CM DATA-CM DATA-ERR F117900400015 MEV ADEG MB/SR MB/SR F117900400016 0. 16.834 2.102E-01 6.999E-02 F117900400017 0. 22.661 1.4004E-01 2.933E-02 F117900400018 0. 28.326 1.3988E-01 3.066E-02 F117900400019 0. 33.591 1.3039E-01 2.932E-02 F117900400020 0. 39.256 1.3023E-01 2.933E-02 F117900400021 0. 44.111 1.1009E-01 1.867E-02 F117900400022 0. 49.651 9.259E-02 1.999E-02 F117900400023 0. 55.386 5.577E-02 9.32E-03 F117900400024 0. 60.226 3.363E-02 9.31E-03 F117900400025 0. 64.800 2.083E-02 5.33E-03 F117900400026 0. 70.470 2.133E-02 4.66E-03 F117900400027 0. 75.117 1.853E-02 6.65E-03 F117900400028 0. 80.482 2.304E-02 5.32E-03 F117900400029 0. 85.771 1.689E-02 4.66E-03 F117900400030 0. 90.803 2.141E-02 5.98E-03 F117900400031 0. 96.131 2.059E-02 5.99E-03 F117900400032 0. 106.14 2.164E-02 5.33E-03 F117900400033 0. 116.12 1.868E-02 6.66E-03 F117900400034 0. 125.38 9.08E-03 3.99E-03 F117900400035 1.61 17.615 2.303E-01 6.932E-02 F117900400036 1.61 23.297 1.8951E-01 5.866E-02 F117900400037 1.61 28.605 1.4006E-01 3.019E-02 F117900400038 1.61 34.127 1.3061E-01 1.932E-02 F117900400039 1.61 39.643 1.1982E-01 2.041E-02 F117900400040 1.61 45.112 1.0037E-01 2.03E-02 F117900400041 1.61 50.688 1.0091E-01 1.999E-02 F117900400042 1.61 55.647 4.747E-02 9.99E-03 F117900400043 1.61 60.863 4.202E-02 5.33E-03 F117900400044 1.61 64.707 2.527E-02 5.33E-03 F117900400045 1.61 69.920 1.915E-02 4.66E-03 F117900400046 1.61 75.525 2.503E-02 4.65E-03 F117900400047 1.61 80.389 1.492E-02 3.99E-03 F117900400048 1.61 85.356 2.414E-02 5.33E-03 F117900400049 1.61 90.604 2.469E-02 4.66E-03 F117900400050 1.61 95.504 2.125E-02 3.99E-03 F117900400051 1.61 104.37 2.372E-02 5.97E-03 F117900400052 1.61 114.20 2.35E-02 5.33E-03 F117900400053 1.61 123.69 1.996E-02 4.67E-03 F117900400054 ENDDATA 40 0 F117900400055 ENDSUBENT 54 0 F117900499999 ENDENTRY 4 0 F117999999999