ENTRY F1221 20200117 F075F122100000001 SUBENT F1221001 20200117 F075F122100100001 BIB 8 11 F122100100002 TITLE Excitation function of reaction Cu-65(d,2n)Zn-65 and F122100100003 yield of isotope Zn-65. F122100100004 AUTHOR (P.P.Dmitriev,N.N.Krasnov) F122100100005 INSTITUTE (4RUSFEI) F122100100006 REFERENCE (J,AE,18,184,1965) F122100100007 (J,SJA,18,228,1965) English translation F122100100008 FACILITY (CYCLO,4RUSFEI) 1.5-m cyclotron was used. F122100100009 METHOD (ACTIV) F122100100010 DECAY-DATA (30-ZN-65,240.D) F122100100011 HISTORY (20141117C) F122100100012 (20200117A) "EC" was deleted in DECAY-DATA in Sub 001. F122100100013 ENDBIB 11 0 F122100100014 NOCOMMON 0 0 F122100100015 ENDSUBENT 14 0 F122100199999 SUBENT F1221002 20141117 F056F122100200001 BIB 7 13 F122100200002 REACTION (29-CU-65(D,2N)30-ZN-65,,SIG) F122100200003 COMMENT The excitation function is presented as a mean of two F122100200004 run of measurements. F122100200005 SAMPLE The stack of 32 Cu foils with 15.5 mg/cm2 thickness of F122100200006 each foil was used. F122100200007 METHOD (STTA) F122100200008 DETECTOR (SCIN) Scintillation gamma spectrometer F122100200009 ERR-ANALYS (EN-ERR-DIG) Energy digitizing error F122100200010 (ERR-DIG) Data digitizing error F122100200011 (DATA-ERR) The accuracy of excitation function was F122100200012 defined taking into account the errors of beam current F122100200013 measurement and the errors of Zn-65 standard. F122100200014 STATUS (CURVE) Figure from the reference, page 184. F122100200015 ENDBIB 13 0 F122100200016 COMMON 3 3 F122100200017 DATA-ERR EN-ERR-DIG ERR-DIG F122100200018 PER-CENT MEV MB F122100200019 15. 0.067 2.00 F122100200020 ENDCOMMON 3 0 F122100200021 DATA 2 19 F122100200022 EN DATA F122100200023 MEV MB F122100200024 6.242 24.12 F122100200025 6.966 73.45 F122100200026 7.777 209.37 F122100200027 8.583 291.68 F122100200028 10.042 530.55 F122100200029 10.769 625.25 F122100200030 12.462 789.84 F122100200031 13.105 818.58 F122100200032 14.229 876.07 F122100200033 15.111 904.76 F122100200034 15.593 929.40 F122100200035 16.152 912.79 F122100200036 17.031 900.23 F122100200037 18.548 854.55 F122100200038 19.185 821.43 F122100200039 19.823 796.55 F122100200040 20.058 734.64 F122100200041 20.296 713.97 F122100200042 20.775 697.38 F122100200043 ENDDATA 21 0 F122100200044 ENDSUBENT 43 0 F122100299999 SUBENT F1221003 20141117 F056F122100300001 BIB 3 4 F122100300002 REACTION (29-CU-65(D,2N)30-ZN-65,,TTY,,PHY,DERIV) F122100300003 ANALYSIS Data were derived by integration of excitation functionF122100300004 STATUS (TABLE) Data were taken from the free text, page 184. F122100300005 (DEP,F1221002) Excitation function (Ed < 21 MeV). F122100300006 ENDBIB 4 0 F122100300007 NOCOMMON 0 0 F122100300008 DATA 2 1 F122100300009 EN DATA F122100300010 MEV MUCI/MUAHR F122100300011 20. 16. F122100300012 ENDDATA 3 0 F122100300013 ENDSUBENT 12 0 F122100399999 SUBENT F1221004 20141117 F056F122100400001 BIB 6 10 F122100400002 REACTION (29-CU-65(D,2N)30-ZN-65,,TTY,,PHY) F122100400003 SAMPLE Two thick copper targets for two beam currents (300 F122100400004 and 600 muA) were used. F122100400005 METHOD (CHSEP) F122100400006 DETECTOR (IOCH) Ionization chamber (4pi geometry) calibrated F122100400007 by Ra and Co-60 sources was used. F122100400008 ERR-ANALYS (DATA-ERR) No source of uncertainties is given. F122100400009 (ERR-1) Error of the beam current. F122100400010 (ERR-2) Error of the target activity determination. F122100400011 STATUS (TABLE) Data were taken from the free text, page 184. F122100400012 ENDBIB 10 0 F122100400013 NOCOMMON 0 0 F122100400014 DATA 5 1 F122100400015 EN DATA DATA-ERR ERR-1 ERR-2 F122100400016 MEV MUCI/MUAHR MUCI/MUAHR PER-CENT PER-CENT F122100400017 20. 16. 2. 5. 10. F122100400018 ENDDATA 3 0 F122100400019 ENDSUBENT 18 0 F122100499999 ENDENTRY 4 0 F122199999999