ENTRY F1244 20141203 F056F124400000001 SUBENT F1244001 20141203 F056F124400100001 BIB 9 23 F124400100002 TITLE Plutonium-237 production by irradiation of highly F124400100003 enriched uranium targets. F124400100004 AUTHOR (A.D.Gedeonov,L.A.Pelevin,V.I.Kucheruk,L.P.Bakushkina, F124400100005 V.Yu.Shkroev) F124400100006 INSTITUTE (4RUSRI) F124400100007 (4RUSSUL) F124400100008 REFERENCE (C,91VILLIG,,82,1991) F124400100009 (C,88BAKU,,359,1988) Preliminary results. F124400100010 FACILITY (CYCLO,4ZZZDUB) F124400100011 SAMPLE (92-U-235,ENR=0.999920) Stack of aluminum foils coveredF124400100012 by U-235 layer (10.2 mg/cm2). F124400100013 Isotopic content of enriched U-235 targets F124400100014 Nuclide Content (%) F124400100015 U-234 0.0020 + - 0.0005 F124400100016 U-235 99.9920 + - 0.0005 F124400100017 U-238 0.0020 + - 0.0005 F124400100018 METHOD (ACTIV) F124400100019 (ASPEC) F124400100020 (GSPEC) F124400100021 (STTA) F124400100022 (CHSEP) F124400100023 ERR-ANALYS (DATA-ERR) No source of uncertainties is given. F124400100024 HISTORY (20141203C) F124400100025 ENDBIB 23 0 F124400100026 NOCOMMON 0 0 F124400100027 ENDSUBENT 26 0 F124400199999 SUBENT F1244002 20141203 F056F124400200001 BIB 4 8 F124400200002 REACTION (92-U-235(HE3,N)94-PU-237,,SIG) F124400200003 DETECTOR (HPGE) Semiconductor detector with resolution of F124400200004 0.9 keV (at 122.06 keV) was used for determination of F124400200005 Pu-237 activity. F124400200006 DECAY-DATA (94-PU-237-G,45.2D,DG,59.54,0.0329, F124400200007 DG,97.08,0.137, F124400200008 DG,101.07,0.218) F124400200009 STATUS (TABLE) Table 3 from C,91VILLIG,,82,1991. F124400200010 ENDBIB 8 0 F124400200011 NOCOMMON 0 0 F124400200012 DATA 3 5 F124400200013 EN DATA DATA-ERR F124400200014 MEV MB MB F124400200015 41.6 0.13 0.02 F124400200016 36.8 0.12 0.02 F124400200017 31.4 0.09 0.01 F124400200018 25.5 0.036 0.004 F124400200019 17.2 0.0042 0.0006 F124400200020 ENDDATA 7 0 F124400200021 ENDSUBENT 20 0 F124400299999 SUBENT F1244003 20141203 F056F124400300001 BIB 4 5 F124400300002 REACTION (92-U-235(HE3,X)94-PU-236,CUM,SIG) F124400300003 DETECTOR (IOCH) Alpha-spectrometer with pulse ionization F124400300004 chamber was used for determination of Pu-236 activity. F124400300005 DECAY-DATA (94-PU-236,2.85YR,A) F124400300006 STATUS (TABLE) Table 3 from C,91VILLIG,,82,1991. F124400300007 ENDBIB 5 0 F124400300008 NOCOMMON 0 0 F124400300009 DATA 3 5 F124400300010 EN DATA DATA-ERR F124400300011 MEV MB MB F124400300012 41.6 10.6 1.4 F124400300013 36.8 11.5 1.4 F124400300014 31.4 11.5 1.8 F124400300015 25.5 7.8 0.9 F124400300016 17.2 0.17 0.02 F124400300017 ENDDATA 7 0 F124400300018 ENDSUBENT 17 0 F124400399999 ENDENTRY 3 0 F124499999999