ENTRY F1258 20151007 F060F125800000001 SUBENT F1258001 20151007 F060F125800100001 BIB 12 19 F125800100002 TITLE Application of BaF2 scintillator to off-line gamma-ray F125800100003 spectroscopy. F125800100004 AUTHOR (P.Kozma,V.V.Yanovsky) F125800100005 INSTITUTE (4ZZZDUB,4RUSLIN) F125800100006 REFERENCE (J,CZJ,40,393,1990) F125800100007 #doi:10.1007/BF01597913 F125800100008 REL-REF (R,,U.Reus+,J,AND,29,1,1983) Decay-data are presented. F125800100009 FACILITY (SYNCH,4ZZZDUB) F125800100010 INC-SOURCE The irradiation periods were equal to 10**13 total fluxF125800100011 particles. F125800100012 SAMPLE The stacks of three high purity Al foils (20 mg/cm2 F125800100013 thickness) were used. The diameter of the target discs F125800100014 was 3.2 cm. F125800100015 DETECTOR (BAF2) Crystal of about 150 cm3 in volume. F125800100016 METHOD (ACTIV,STTA,GSPEC) F125800100017 ERR-ANALYS (DATA-ERR) The error is a sum of counting statistic F125800100018 error, target thickness determination and beam flux F125800100019 monitor. F125800100020 HISTORY (20151007C) F125800100021 ENDBIB 19 0 F125800100022 NOCOMMON 0 0 F125800100023 ENDSUBENT 22 0 F125800199999 SUBENT F1258002 20151007 F060F125800200001 BIB 3 3 F125800200002 REACTION (13-AL-27(D,X)11-NA-24,,SIG) F125800200003 DECAY-DATA (11-NA-24,15.02HR,DG,1368.5,1.0) F125800200004 STATUS (TABLE) Data were taken from the text (page 396). F125800200005 ENDBIB 3 0 F125800200006 NOCOMMON 0 0 F125800200007 DATA 3 2 F125800200008 EN DATA DATA-ERR F125800200009 GEV/A MB MB F125800200010 3.0 14.1 1.3 F125800200011 3.65 14.7 1.2 F125800200012 ENDDATA 4 0 F125800200013 ENDSUBENT 12 0 F125800299999 ENDENTRY 2 0 F125899999999