ENTRY F1286 20170711 F065F128600000001 SUBENT F1286001 20170711 F065F128600100001 BIB 9 27 F128600100002 TITLE Investigation of the reaction D(He-4,gamma)Li-6 at F128600100003 ultralow energies. F128600100004 AUTHOR (Yu.B.Burkatovskaya,V.M.Bystritsky,G.N.Dudkin, F128600100005 A.R.Krylov,A.S.Lysakov,S.Gazi,J.Guran,B.A.Nechaev, F128600100006 V.N.Padalko,A.B.Sadovsky,Yu.G.Tuleushev,M.Filipowicz, F128600100007 A.V.Philippov) F128600100008 INSTITUTE (4RUSTPI,4ZZZDUB,4KASKAZ,3POLITJ) F128600100009 (3SLKSLO) Institute of electrical engineering SAS, F128600100010 Bratislava, Slovakia F128600100011 REFERENCE (J,FCY/L,13,(2),304,2016) F128600100012 (J,PPN/L,13,(2),190,2016) English translation F128600100013 #doi:10.1134/S1547477116020059 F128600100014 (J,YF,80,94,2017) F128600100015 #doi:10.7868/50044002717010056 F128600100016 (J,PAN,80,203,2017) English translation F128600100017 #doi:10.1134/S1063778817010057 F128600100018 FACILITY (ACCEL,4RUSTPI) Pulsed plasma Hall accelerator was F128600100019 used. F128600100020 METHOD (BCINT,GSPEC) F128600100021 DETECTOR (NAICR) Gamma rays with the energy Eg=(1484+ -11)keV F128600100022 were recorded by eight NaI(Tl)-based detectors F128600100023 (10*10*40 cm) placed around the target. Total weight F128600100024 of all detectors was 117 kg. F128600100025 STATUS (TABLE) Data from the text, page 304, fig.5 from the F128600100026 article. F128600100027 HISTORY (20161118C) F128600100028 (20170711A) New Reference code was added. F128600100029 ENDBIB 27 0 F128600100030 NOCOMMON 0 0 F128600100031 ENDSUBENT 30 0 F128600199999 SUBENT F1286002 20161118 F063F128600200001 BIB 4 10 F128600200002 REACTION (1-H-2(A,G)3-LI-6,,SIG) F128600200003 SAMPLE Titanium deuteride was used as a target. It was F128600200004 deposited on the stainless-steel backing by magnetron F128600200005 sputtering. Titanium deuteride layer was 1.5-2 mu-m F128600200006 thick. The target diameter was 98 mm and the thickness F128600200007 was 0.1 mm. F128600200008 DETECTOR (NAICR)Additional NaI(Tl) detector was used (150 mm F128600200009 diam., 100 mm thickness). F128600200010 INC-SOURCE There were 5*10**14 He-4 ions per pulse. Total number F128600200011 of He-4 ions was 1.187*10**19. F128600200012 ENDBIB 10 0 F128600200013 NOCOMMON 0 0 F128600200014 DATA 2 1 F128600200015 EN DATA-MAX F128600200016 KEV PB F128600200017 30. 12. F128600200018 ENDDATA 3 0 F128600200019 ENDSUBENT 18 0 F128600299999 SUBENT F1286003 20161118 F063F128600300001 BIB 4 6 F128600300002 REACTION (1-H-2(A,G)3-LI-6,,SIG) F128600300003 SAMPLE Zirconium deuteride was used as a target. F128600300004 DETECTOR (TELES,HE3SP) 10 tubes with 3 cm diameter and 50 cm F128600300005 length were used as the counters. They were filled in F128600300006 3He+Ar+CO2 mixture at 4 atm pressure. F128600300007 INC-SOURCE Total number of He-4 ions was 1.211*10**19. F128600300008 ENDBIB 6 0 F128600300009 NOCOMMON 0 0 F128600300010 DATA 2 1 F128600300011 EN DATA-MAX F128600300012 KEV PB F128600300013 36. 7. F128600300014 ENDDATA 3 0 F128600300015 ENDSUBENT 14 0 F128600399999 ENDENTRY 3 0 F128699999999