/* 2004-03-11 FILE IS GENERATED BY HENDEL */ \\BIB,1[67; D#=D1434; TITLE=/Nuclear structure of even lead isotopes by the (p,t) reaction/; ATH=(M.TAKAHASHI'1', T.MURAKAMI'1', S.MORITA'1', H.ORIHARA'2', Y.ISHIZAKI'3', H.YAMAGUCHI'4'); INST-ATH=(2JPNTOH'1', 2JPNTOH'2', 2JPNINS'3', 2JPNTKS'4'); /* '1' Department of Physics */ /* '2' Cyclotron and Radioisotope Center */ /* '3' Institute for Nuclear Study */ /* '4' Faculty of General Education */ REF=PR/C; VLP=27(1983)1454; RCTS=(208PB(P,T)206PB, 206PB(P,T)204PB, 204PB(P,T)202PB); PHQS=ANGL-DSTRN; \\EXP,1[67; /* 2003-10-24 : Converted, Data converted to EXFOR E1434 and EXFOR O0685 */ PHQ=ANGL-DSTRN; ENR=>99%; POL-TGT=0%; ALGN-TGT=0%; ACC=SYNCYC; INST-ACC=2JPNINS; INC-ENGY-LAB=51.9MEV; POL-PRJ=0%; DET-PARTCL=T; COINC=NO; ANT-COINC=NO; DET-SYS=(MAG'5',PROP-CNTR'6',SCT); /* '5' To analyze triton momentum */ /* '6' Array of 200 proportional counters serve as position detectors. They form counter telescopes in combination with scintillation counters. */ ERS-DET=[90KEV'7'; /* '7' Overall energy resolution for the tritons of interest */ ANL=DWBA'8'; /* '8' Zero-range DWBA approximation (code DWUCK-4, [W.A.Lanford and J.B.McGrory, Michigan State University Cyclotron Laboratory Report No.MSUCL-81, 1973 (unpublished); Phys. Lett. 45B(1973)283]) */ \\EXP,1; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'9'; /* '9' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,1; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'10'; /* '10' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=0MEV; J-PTY=0+; DELTA-THTC=0.25DEG'11'; /* '11' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'12'; /* '12' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 5.66 85.1 8.13 82.9 11.13 90.9 13.59 104.9 16.08 83.1 18.59 50.8 21.32 15.6 23.67 7.45 26.26 16.5 28.36 23.1 33.52 13.57 39.04 7.38 43.24 13.6 49.12 6.17 54.1 3.77 59.02 5.5 64.57 2.03 \END; /* Data scanned from Fig.2, p1455 in reference by CAJaD */ \\EXP,2; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'13'; /* '13' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,2; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'14'; /* '14' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=1.17MEV; J-PTY=0+; DELTA-THTC=0.25DEG'15'; /* '15' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'16'; /* '16' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'17' (DEG) (UB/SR) (%) 5.65 8.9 +-4. 8.44 14.33 +-X 10.38 15.1 +-X 13.02 15.31 +-X 15.5 11.52 +-X 18.53 4.4 +-16. 21.04 1.38 +-20. 23.2 0.4 +-80. 25.59 2.6 +-12. 28.23 2.82 +-10. 33.01 1.55 +-14. 38.5 0.5 +-60. 43.58 1.22 +-17. 48.9 0.42 +-40. 53.67 0.27 +-30. 58.57 0.57 +-26. 64.07 0.2 +-50. \END; /* Data scanned from Fig.2, p1455 in reference by CAJaD */ /* '17' Uncertainty given by authors */ \\EXP,3; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'18'; /* '18' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,3; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'19'; /* '19' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=0MEV; J-PTY=0+; DELTA-THTC=0.25DEG'20'; /* '20' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'21'; /* '21' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 6.65 115. 8.76 130.6 10.52 150.2 13. 135.5 16.36 123.9 18.86 81.3 21.42 26.1 23.78 10.55 26.54 27.4 28.98 44. 34.5 23.2 39.16 9.62 41.94 18.4 44.57 22.9 49.76 9.6 54.21 5.98 59.65 8.98 64.84 3.67 \END; /* Data scanned from Fig.2, p1455 in reference by CAJaD */ \\EXP,4; RCT=204PB(P,T)202PB; CHM=ELM'22'; /* '22' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,4; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'23'; /* '23' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=0MEV; J-PTY=0+; DELTA-THTC=0.25DEG'24'; /* '24' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'25'; /* '25' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 6.13 161.2 8.24 170. 10.52 181. 12.81 229. 15.64 217. 18.32 149.1 20.86 58.5 23.62 12.97 25.84 31. 27.93 54.8 31.11 58.5 33.61 37.1 36.5 13.48 38.84 8.67 41.08 17.7 46.53 26.2 51.58 6.18 56.33 8.67 61.44 10.13 \END; /* Data scanned from Fig.2, p1455 in reference by CAJaD */ \\EXP,5; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'26'; /* '26' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,5; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'27'; /* '27' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=0.80MEV; J-PTY=2+; DELTA-THTC=0.25DEG'28'; /* '28' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'29'; /* '29' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 6. 239. 8.69 281. 11.39 227. 13.56 174. 15.72 152.3 18.42 135.1 20.58 128.2 23.47 109.3 26. 75.3 28.54 47.9 33.57 48.6 38.25 42.6 43.86 18.2 48.53 20.2 53.58 13.41 58.62 8.65 63.14 7.28 \END; /* Data scanned from Fig.3(left), p1455 in reference by CAJaD */ \\EXP,6; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'30'; /* '30' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,6; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'31'; /* '31' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=1.46MEV; J-PTY=2+; DELTA-THTC=0.25DEG'32'; /* '32' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'33'; /* '33' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'34' (DEG) (UB/SR) (%) 5.52 28.4 +-X 8.37 37.6 +-X 10.53 35.7 +-X 13.04 29.7 +-X 15.56 23.4 +-X 18.44 17.7 +-X 20.6 14.89 +-X 23.83 13.4 +-X 25.62 11.9 +-X 28.87 7.18 +-X 33.89 7.39 +-X 38.73 6.07 +-X 43.77 4.3 +-6. 48.08 3.01 +-6. 53.45 3.83 +-2.3 58.33 1.38 +-22. 63.6 1.38 +-7. \END; /* Data scanned from Fig.3(left), p1455 in reference by CAJaD */ /* '34' Uncertainty given by authors */ \\EXP,7; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'35'; /* '35' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,7; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'36'; /* '36' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=2.40MEV; J-PTY=2+; DELTA-THTC=0.25DEG'37'; /* '37' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'38'; /* '38' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'39' (DEG) (UB/SR) (%) 5.44 20.6 +-X 8.12 26.2 +-X 10.46 23.9 +-X 12.8 18.6 +-X 15.84 18.3 +-X 18. 13.88 +-X 20.7 11.85 +-X 23.21 11.1 +-X 25.73 8.19 +-X 28.61 6.12 +-3. 32.92 4.52 +-X 38.49 3.76 +-3. 43.53 2.3 +-13. 48.37 2.13 +-14. 53.4 1.29 +-20. 58.26 0.76 +-22. 63. 0.82 +-17. \END; /* Data scanned from Fig.3(left), p1455 in reference by CAJaD */ /* '39' Uncertainty given by authors */ \\EXP,8; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'40'; /* '40' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,8; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'41'; /* '41' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=3.77MEV; J-PTY=2+; DELTA-THTC=0.25DEG'42'; /* '42' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'43'; /* '43' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'44' (DEG) (UB/SR) (%) 5.85 56.8 +-X 7.82 59.9 +-X 10.89 48.9 +-X 13.22 41.1 +-X 15.74 30.5 +-X 18.43 28.9 +-X 20.76 26.3 +-X 23.27 23.6 +-X 25.44 15.75 +-X 29.04 9.3 +-X 33.18 8.13 +-X 38.91 7.81 +-X 43.25 3.07 +-7. 47.91 2.99 +-10. 52.74 3.62 +-X 57.77 2.32 +-3. 62.81 1.46 +-10. \END; /* Data scanned from Fig.3(left), p1455 in reference by CAJaD */ /* '44' Uncertainty given by authors */ \\EXP,9; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'45'; /* '45' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,9; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'46'; /* '46' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=0.90MEV; J-PTY=2+; DELTA-THTC=0.25DEG'47'; /* '47' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'48'; /* '48' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 5.75 141.2 8.44 166. 10.96 157.8 13.12 124.7 15.65 92.2 18.17 90. 20.51 85.6 23.21 72.3 25.39 45. 27.92 34.6 32.95 37.2 38.17 33.2 43.06 15.9 48.09 15.57 53.31 13.01 58.59 3.58 63.04 7.34 68.28 4.47 \END; /* Data scanned from Fig.3(left), p1455 in reference by CAJaD */ \\EXP,10; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'49'; /* '49' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,10; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'50'; /* '50' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=1.7MEV; J-PTY=2+; DELTA-THTC=0.25DEG'51'; /* '51' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'52'; /* '52' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'53' (DEG) (UB/SR) (%) 5.37 16.2 +-X 8.23 19.5 +-X 10.02 21.2 +-X 13.07 17.4 +-X 15.41 15.11 +-X 18.11 11.49 +-X 20.08 10.23 +-X 22.78 8.76 +-X 25.3 7.02 +-X 28. 5.41 +-2.2 37.88 3.1 +-13. 43.09 1.8 +-12. 47.75 2.14 +-11. 52.59 1.84 +-13. \END; /* Data scanned from Fig.3(left), p1455 in reference by CAJaD */ /* '53' Uncertainty given by authors */ \\EXP,11; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'54'; /* '54' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,11; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'55'; /* '55' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=2.5MEV; J-PTY=2+; DELTA-THTC=0.25DEG'56'; /* '56' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'57'; /* '57' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'58' (DEG) (UB/SR) (%) 5.16 44.2 +-X 7.3 53.4 +-X 9.81 56.5 +-X 12.51 43.4 +-X 14.48 39.7 +-X 17.17 33.9 +-X 19.51 32.2 +-X 22.38 27.5 +-X 24.72 20.1 +-X 27.41 18.6 +-X 32.45 12.35 +-X 37.13 7.78 +-X 42.33 6.76 +-3. 46.82 4.68 +-4. 52.04 2.99 +-4. 56.9 1.96 +-11. 61.74 1.66 +-11. \END; /* Data scanned from Fig.3(left), p1455 in reference by CAJaD */ /* '58' Uncertainty given by authors */ \\EXP,12; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'59'; /* '59' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,12; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'60'; /* '60' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=3.1MEV; J-PTY=2+; DELTA-THTC=0.25DEG'61'; /* '61' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'62'; /* '62' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'63' (DEG) (UB/SR) (%) 6.64 282. +-X 8.61 305. +-X 11.14 274. +-X 14.63 161. +-X 16.43 153.1 +-X 18.79 137.7 +-X 21.12 147.2 +-X 24.02 127.3 +-X 26.22 91.3 +-X 28.42 65.5 +-X 33.68 50.3 +-X 38.91 44.7 +-X 40.92 35.6 +-X 43.83 29. +-10. 48.92 18.6 +-15. 53.96 19.1 +-13. \END; /* Data scanned from Fig.3(right), p1455 in reference by CAJaD */ /* '63' Uncertainty given by authors */ \\EXP,13; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'64'; /* '64' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,13; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'65'; /* '65' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=3.2MEV; J-PTY=2+; DELTA-THTC=0.25DEG'66'; /* '66' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'67'; /* '67' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'68' (DEG) (UB/SR) (%) 6.4 23.7 +-X 8.7 32. +-X 11.24 27.4 +-X 13.62 20.1 +-X 16.16 16.7 +-X 19.25 14.14 +-X 21.24 13.08 +-X 23.6 10.63 +-X 26.55 6.65 +-X 29.24 7.02 +-X 34.15 4.7 +-X 38.81 5.36 +-2. 40.83 4.19 +-2. 43.92 3.28 +-2. 49.39 1.87 +-14. 54.83 1.34 +-13. \END; /* Data scanned from Fig.3(right), p1455 in reference by CAJaD */ /* '68' Uncertainty given by authors */ \\EXP,14; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'69'; /* '69' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,14; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'70'; /* '70' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=3.81MEV; J-PTY=2+; DELTA-THTC=0.25DEG'71'; /* '71' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'72'; /* '72' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'73' (DEG) (UB/SR) (%) 5.78 25.2 +-X 8.47 26.3 +-X 11.21 20.2 +-X 14.5 13.02 +-X 16.13 12.36 +-X 18.12 12.39 +-X 20.8 13.1 +-X 24.1 8.46 +-2. 26.29 6.75 +-2. 29. 6.17 +-2. 33.58 3.3 +-12. 38.47 2.5 +-16. 41.04 1.7 +-18. 43.49 3. +-13. 48.63 1.37 +-21. 53.89 1.04 +-25. 58.6 0.84 +-25. 63.37 0.4 +-40. \END; /* Data scanned from Fig.3(right), p1455 in reference by CAJaD */ /* '73' Uncertainty given by authors */ \\EXP,15; RCT=204PB(P,T)202PB; CHM=ELM'74'; /* '74' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,15; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'75'; /* '75' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=0.95MEV; J-PTY=2+; DELTA-THTC=0.25DEG'76'; /* '76' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'77'; /* '77' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 4.38 118.2 6.01 126.6 8.18 117. 10.53 106.7 13.24 85. 15.41 77.5 17.94 73.6 20.1 58.6 23. 36.1 25.35 25.8 28.06 19. 30.95 21.5 33.11 23.3 35.47 21.9 38. 14.8 43.06 10.18 47.94 10.23 \END; /* Data scanned from Fig.3(right), p1455 in reference by CAJaD */ \\EXP,16; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'78'; /* '78' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,16; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'79'; /* '79' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=4.16MEV; J-PTY=3-; DELTA-THTC=0.25DEG'80'; /* '80' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'81'; /* '81' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'82' (DEG) (UB/SR) (%) 5.7 74.4 +-X 8.04 61.1 +-X 10.92 50.2 +-X 13.63 39.2 +-X 15.8 45.3 +-X 18.51 39.7 +-X 21.21 34. +-X 24.1 31.8 +-X 26.25 23.5 +-X 28.59 15.07 +-X 33.45 10.04 +-X 38.68 7.93 +-X 43.72 5.57 +-X 48.78 4.7 +-X 53.81 2.7 +-15. 58.49 1.58 +-15. 64.08 1.24 +-23. \END; /* Data scanned from Fig.4, p1457 in reference by CAJaD */ /* '82' Uncertainty given by authors */ \\EXP,17; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'83'; /* '83' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,17; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'84'; /* '84' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=2.6MEV; J-PTY=3-; DELTA-THTC=0.25DEG'85'; /* '85' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'86'; /* '86' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'87' (DEG) (UB/SR) (%) 5.44 94.8 +-X 8.16 90. +-X 10.69 76.9 +-X 13.41 64.8 +-X 15.4 55.3 +-X 18.3 48.5 +-X 21.02 47.3 +-X 23.2 38.3 +-X 25.73 28.6 +-X 28.45 24.4 +-X 33.35 14.16 +-X 38.97 12.45 +-X 43.48 7.32 +-X 48.21 4.61 +-X 53.28 5.22 +-X 58.72 3.11 +-3. \END; /* Data scanned from Fig.4, p1457 in reference by CAJaD */ /* '87' Uncertainty given by authors */ \\EXP,18; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'88'; /* '88' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,18; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'89'; /* '89' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=3.42MEV; J-PTY=3-; DELTA-THTC=0.25DEG'90'; /* '90' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'91'; /* '91' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'92' (DEG) (UB/SR) (%) 5.23 61.2 +-X 7.39 56.7 +-X 10.28 47.9 +-X 12.61 35.5 +-X 15.14 34.7 +-X 17.67 35.2 +-X 20.02 36.7 +-X 22.73 31.1 +-X 25.24 22.7 +-X 27.95 14.23 +-X 32.8 9.91 +-X 37.67 7.86 +-X 42.72 7.11 +-X 45.44 7.13 +-X 48.13 4.76 +-X 52.8 2.62 +-11. \END; /* Data scanned from Fig.4, p1457 in reference by CAJaD */ /* '92' Uncertainty given by authors */ \\EXP,19; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'93'; /* '93' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,19; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'94'; /* '94' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=1.69MEV; J-PTY=4+; DELTA-THTC=0.25DEG'95'; /* '95' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'96'; /* '96' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 5.61 300. 7.81 257. 10.4 201. 13.39 191. 15.78 183. 18.56 168. 19.96 146. 22.15 138. 23.94 130.5 24.94 116.4 26.93 111.7 28.73 104.1 29.72 94.2 33.32 62.2 37.9 44.9 43.48 33.8 48.67 21.1 53.65 15.2 56.24 14.6 59.43 11.31 63.82 7.48 \END; /* Data scanned from Fig.5, p1457(left) in reference by CAJaD */ \\EXP,20; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'97'; /* '97' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,20; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'98'; /* '98' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=1.99MEV; J-PTY=4+; DELTA-THTC=0.25DEG'99'; /* '99' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'100'; /* '100' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 5.1 144. 7.89 117.3 10.49 91.2 12.88 81.7 15.26 82. 18.05 71.5 20.45 60.5 23.62 56.6 26.02 52.2 29.21 47.5 34. 26.7 38.59 19.2 43.78 13.36 48.56 8.79 53.74 6.77 58.52 5.13 63.91 3.02 \END; /* Data scanned from Fig.5, p1457(left) in reference by CAJaD */ \\EXP,21; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'101'; /* '101' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,21; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'102'; /* '102' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=2.93MEV; J-PTY=4+; DELTA-THTC=0.25DEG'103'; /* '103' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'104'; /* '104' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 5.36 170. 8.15 129.1 10.54 107.1 13.33 102.7 15.33 79.3 17.32 77.1 20.1 77.2 23.29 67.9 26.68 48.1 28.28 48.2 33.46 27.5 38.84 22.5 43.83 17.4 48.82 9.67 54.2 6.47 58.78 6.78 63.36 5.39 \END; /* Data scanned from Fig.5, p1457(left) in reference by CAJaD */ \\EXP,22; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'105'; /* '105' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,22; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'106'; /* '106' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=1.27MEV; J-PTY=4+; DELTA-THTC=0.25DEG'107'; /* '107' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'108'; /* '108' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 4.82 207. 7.41 153. 10.01 113.6 12.4 93.1 15.38 98.6 17.77 94.6 20.37 74.2 22.76 68.2 24.55 63.5 27.94 55.1 33.52 37. 38.11 20.6 40.5 20.3 43.47 18.7 47.88 11.34 53.07 6.41 58.05 5.56 63.24 3.1 68.42 2.3 \END; /* Data scanned from Fig.5, p1457(left) in reference by CAJaD */ \\EXP,23; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'109'; /* '109' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,23; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'110'; /* '110' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=1.54MEV; J-PTY=4+; DELTA-THTC=0.25DEG'111'; /* '111' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'112'; /* '112' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'113' (DEG) (UB/SR) (%) 4.51 80.4 +-X 7.1 56. +-X 10.09 49.9 +-X 12.69 37.9 +-X 14.47 36.9 +-X 17.07 29.3 +-X 19.46 26.1 +-X 22.25 26.1 +-X 24.84 22.6 +-X 28.02 21.1 +-X 32.62 11.47 +-X 38. 8.48 +-X 39.99 7.34 +-X 42.98 6.45 +-X 47.77 4.43 +-X 53.15 2.87 +-X 58.13 2.8 +-X 62.52 1.5 +-18. \END; /* Data scanned from Fig.5, p1457(left) in reference by CAJaD */ /* '113' Uncertainty given by authors */ \\EXP,24; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'114'; /* '114' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,24; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'115'; /* '115' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=1.80MEV; J-PTY=4+; DELTA-THTC=0.25DEG'116'; /* '116' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'117'; /* '117' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'118' (DEG) (UB/SR) (%) 4.77 76.1 +-X 7.56 57.5 +-X 9.36 43.4 +-X 11.75 38.6 +-X 14.54 37. +-X 17.13 33.3 +-X 20.12 26.7 +-X 22.31 24.5 +-X 24.9 21.1 +-X 27.69 22.4 +-X 32.68 12.62 +-X 37.27 8.23 +-X 40.45 9. +-X 42.84 8.49 +-X 47.82 6.23 +-X 53.01 3.61 +-X 57.98 3.31 +-7. 62.78 1.83 +-15. \END; /* Data scanned from Fig.5, p1457(left) in reference by CAJaD */ /* '118' Uncertainty given by authors */ \\EXP,25; RCT=204PB(P,T)202PB; CHM=ELM'119'; /* '119' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,25; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'120'; /* '120' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=1.37MEV; J-PTY=4+; DELTA-THTC=0.25DEG'121'; /* '121' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'122'; /* '122' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 7.05 212. 8.55 162. 10.97 116.5 13.95 98.1 16.55 97. 18.6 81.7 21.2 69.7 23.43 57.9 25.66 62.9 28.44 56.6 31.42 45.2 33.84 34.2 36.46 22.3 38.7 17.1 40.2 16.1 41.85 15.02 51.53 7.55 56.72 6.29 61.94 4.58 \END; /* Data scanned from Fig.5(right), p1457 in reference by CAJaD */ \\EXP,26; RCT=204PB(P,T)202PB; CHM=ELM'123'; /* '123' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,26; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'124'; /* '124' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=1.60MEV; J-PTY=4+; DELTA-THTC=0.25DEG'125'; /* '125' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'126'; /* '126' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'127' (DEG) (UB/SR) (%) 6.71 388. +-X 8.93 302. +-X 11.52 220. +-X 13.55 233. +-X 16.31 221. +-X 18.72 149. +-X 21.31 120.8 +-X 23.71 100.5 +-X 26.1 116.6 +-X 28.87 88.5 +-X 31.82 87.6 +-X 34.23 58.2 +-X 36.64 45.3 +-X 38.86 33.4 +-5. 41.62 36.3 +-5. 46.43 19.5 +-13. 51.41 13.5 +-13. 56.58 11.9 +-11. 61.75 8.9 +-11. \END; /* Data scanned from Fig.5(right), p1457 in reference by CAJaD */ /* '127' Uncertainty given by authors */ \\EXP,27; RCT=204PB(P,T)202PB; CHM=ELM'128'; /* '128' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,27; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'129'; /* '129' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=1.77MEV; J-PTY=4+; DELTA-THTC=0.25DEG'130'; /* '130' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'131'; /* '131' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'132' (DEG) (UB/SR) (%) 6.27 14.78 +-X 8.32 13.32 +-2. 10.54 11.69 +-X 13.31 7.8 +-8. 18.12 4. +-10. 23.46 4. +-10. 25.85 4.7 +-11. 27.9 3.1 +-13. 30.67 2.6 +-12. 33.46 1.14 +-22. 35.65 1.59 +-17. 38.23 1.97 +-6. 40.45 1.71 +-8. 46.18 0.98 +-18. 50.79 0.84 +-14. 56.15 0.5 +-22. \END; /* Data scanned from Fig.5(right), p1457 in reference by CAJaD */ /* '132' Uncertainty given by authors */ \\EXP,28; RCT=204PB(P,T)202PB; CHM=ELM'133'; /* '133' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,28; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'134'; /* '134' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=1.9MEV; J-PTY=4+; DELTA-THTC=0.25DEG'135'; /* '135' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'136'; /* '136' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'137' (DEG) (UB/SR) (%) 5.88 29.7 +-X 7.74 19.7 +-X 9.96 13.2 +-3. 12.72 11.75 +-3. 15.5 9.39 +-3. 17.9 7.5 +-3. 20.3 6.93 +-4. 22.5 6.76 +-4. 25.08 8.6 +-3. 28.04 6.18 +-X 30.44 5.95 +-X 33.41 3.79 +-3. 35.63 2.65 +-3. 38.02 2.69 +-3. 40.6 2.33 +-4. 45.78 1.7 +-5. 50.96 0.962 +-6. 55.74 1.03 +-10. 60.9 0.94 +-15. \END; /* Data scanned from Fig.5(right), p1457 in reference by CAJaD */ /* '137' Uncertainty given by authors */ \\EXP,29; RCT=204PB(P,T)202PB; CHM=ELM'138'; /* '138' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,29; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'139'; /* '139' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=2.5MEV; J-PTY=4+; DELTA-THTC=0.25DEG'140'; /* '140' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'141'; /* '141' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'142' (DEG) (UB/SR) (%) 5.53 37.6 +-X 7.02 30.3 +-X 9.25 26.8 +-X 12.04 23.7 +-X 14.64 23.4 +-X 17.42 20.4 +-X 19.84 17.8 +-X 22.06 21.3 +-X 25.41 16.6 +-X 27.83 14.73 +-X 30.27 7.23 +-3. 32.67 7.24 +-3. 35.29 5.01 +-X 37.69 6.59 +-3. 40.29 6.5 +-3. 45.69 3.62 +-X 50.9 2.72 +-X 56.28 2.76 +-X 60.74 1.99 +-X \END; /* Data scanned from Fig.5(right), p1457 in reference by CAJaD */ /* '142' Uncertainty given by authors */ \\EXP,30; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'143'; /* '143' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,30; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'144'; /* '144' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=3.54MEV; J-PTY=5-; DELTA-THTC=0.25DEG'145'; /* '145' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'146'; /* '146' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 6.72 104.5 9.21 100.5 11.87 93.1 14.18 84. 16.84 70.2 19.84 55.8 22.33 46.6 24.46 42.6 27.66 40. 29.08 36.1 34.39 21.6 39.72 16.3 44.5 11.56 50.17 7.12 55.5 6.1 59.4 3.95 64.55 3.84 \END; /* Data scanned from Fig.6, p1457 in reference by CAJaD */ \\EXP,31; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'147'; /* '147' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,31; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'148'; /* '148' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=2.79MEV; J-PTY=5-; DELTA-THTC=0.25DEG'149'; /* '149' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'150'; /* '150' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 6.71 84.9 8.84 74.8 14.15 41.1 16.99 35.7 19.65 31.1 21.78 25. 24.26 23.5 26.94 22.3 34.91 12.42 39.69 7.46 45. 4.49 49.44 3.9 54.94 2.53 59.91 2.26 64.51 1.321 \END; /* Data scanned from Fig.6, p1457 in reference by CAJaD */ \\EXP,32; RCT=204PB(P,T)202PB; CHM=ELM'151'; /* '151' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,32; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'152'; /* '152' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=2.03MEV; J-PTY=5-; DELTA-THTC=0.25DEG'153'; /* '153' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'154'; /* '154' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 6. 67. 7.96 69.6 10.26 59.7 12.93 62.9 15.76 39.7 18.42 39.2 20.55 28.1 23.03 25.4 25.69 20.7 28.18 23. 30.68 20.7 33.32 16.3 35.8 12.6 38.11 10.02 40.76 7.47 45.74 6.66 50.88 4.84 56.73 3.18 61.17 3.14 \END; /* Data scanned from Fig.6, p1457 in reference by CAJaD */ \\EXP,33; RCT=204PB(P,T)202PB; CHM=ELM'155'; /* '155' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,33; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'156'; /* '156' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=2.6MEV; J-PTY=5-; DELTA-THTC=0.25DEG'157'; /* '157' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'158'; /* '158' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 6.81 73.2 8.04 57.2 10.7 49.6 12.99 28.4 15.66 25.2 17.97 23.7 20.64 25.2 23.47 19. 25.96 21.3 28.28 22.4 30.93 17.5 33.59 13.01 36.06 7.07 38.18 6.05 41.56 6.62 46.19 7.63 50.61 3.99 56.09 1.76 61.07 1.69 \END; /* Data scanned from Fig.6, p1457 in reference by CAJaD */ \\EXP,34; RCT=204PB(P,T)202PB; CHM=ELM'159'; /* '159' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,34; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'160'; /* '160' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=3.0MEV; J-PTY=5-; DELTA-THTC=0.25DEG'161'; /* '161' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'162'; /* '162' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 6.34 33.4 7.94 39. 10.06 27.6 12.73 26.6 15.39 20.4 17.35 23.1 19.82 15. 23.18 11.33 25.32 12.89 30.3 12.43 33.29 5.63 35.6 4.96 38.08 4.04 40.57 3.85 45.73 4.33 50.69 2.67 56.01 1.82 60.8 1.584 \END; /* Data scanned from Fig.6, p1457 in reference by CAJaD */ \\EXP,35; RCT=204PB(P,T)202PB; CHM=ELM'163'; /* '163' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,35; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'164'; /* '164' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=3.80MEV; J-PTY=5-; DELTA-THTC=0.25DEG'165'; /* '165' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'166'; /* '166' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 7.15 41.4 10.17 37.3 12.66 39.3 14.96 30.3 17.63 28.1 19.75 24.3 22.59 18.3 25.62 24. 27.75 19.5 30.23 15.47 33.24 10.61 35.19 10.21 38.03 8.51 40.85 5.06 45.29 4.51 50.62 3.91 56.12 3.1 60.91 2.18 \END; /* Data scanned from Fig.6, p1457 in reference by CAJaD */ \\EXP,36; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'167'; /* '167' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,36; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'168'; /* '168' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=3.26MEV; J-PTY=6+; DELTA-THTC=0.25DEG'169'; /* '169' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'170'; /* '170' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 5.83 555. 6.97 630. 10.11 556. 12.48 470. 15.45 361. 18.22 289. 21. 206. 22.98 175. 25.54 154. 28.09 137.9 33.17 123.6 39.06 93.6 43.67 47.2 48.58 38.3 53.93 23.2 59.26 15.5 63.98 12.39 \END; /* Data scanned from Fig., p14 in reference by CAJaD */ \\EXP,37; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'171'; /* '171' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,37; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'172'; /* '172' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=6.5MEV; J-PTY=6+; DELTA-THTC=0.25DEG'173'; /* '173' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'174'; /* '174' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'175' (DEG) (UB/SR) (%) 5.87 49. +-X 8.59 47. +-X 10.72 47.1 +-X 12.87 42.7 +-X 16.02 32.2 +-X 18.57 26.4 +-X 21.14 19.3 +-X 24.06 18.3 +-X 26.24 13.99 +-X 28.79 11.32 +-X 34.44 9.45 +-X 38.96 6.73 +-4. 44.25 5.01 +-4. 48.91 4.6 +-11. 53.95 4.3 +-12. 59.56 1.51 +-14. 64.15 2.14 +-12. \END; /* Data scanned from Fig.7, p1458 in reference by CAJaD */ /* '175' Uncertainty given by authors */ \\EXP,38; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'176'; /* '176' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,38; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'177'; /* '177' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=2.82MEV; J-PTY=6+; DELTA-THTC=0.25DEG'178'; /* '178' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'179'; /* '179' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 5.54 471. 7.2 479. 8.26 486. 10.22 459. 13.17 394. 15.36 301. 18.35 205. 20.7 194. 23.87 144. 26.23 130.9 28.96 122.1 33.66 106.2 43.36 45.5 49.45 34.4 54.41 20.7 59.73 14.7 65.02 12.12 70.57 7.19 \END; /* Data scanned from Fig.7, p1458 in reference by CAJaD */ \\EXP,39; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'180'; /* '180' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,39; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'181'; /* '181' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=4.0MEV; J-PTY=6+; DELTA-THTC=0.25DEG'182'; /* '182' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'183'; /* '183' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'184' (DEG) (UB/SR) (%) 6.2 34.2 +-X 8.68 41.1 +-X 11.04 34.3 +-X 13.63 24.4 +-X 15.97 21.5 +-X 18.95 14.5 +-X 21.9 10.79 +-X 24.65 9.12 +-X 26.57 9.65 +-X 29.49 8.87 +-X 34.35 8.16 +-X 39.3 4.52 +-X 41.32 2.84 +-X 49.51 2.05 +-9. 54.59 1.6 +-13. 59.91 0.97 +-16. 64.2 0.85 +-20. \END; /* Data scanned from Fig.7, p1458 in reference by CAJaD */ /* '184' Uncertainty given by authors */ \\EXP,40; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'185'; /* '185' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,40; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'186'; /* '186' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=5.0MEV; J-PTY=6+; DELTA-THTC=0.25DEG'187'; /* '187' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'188'; /* '188' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'189' (DEG) (UB/SR) (%) 6.55 19.1 +-X 9.21 25.1 +-X 11.56 21.8 +-X 13.93 16.5 +-X 16.29 13.73 +-X 19.21 12.83 +-X 21.6 8.89 +-X 24.17 6.71 +-X 26.47 7.42 +-X 29.81 5.85 +-X 34.26 5.71 +-X 38.74 4.98 +-4. 41.92 3.26 +-4. 45.06 2.53 +-X 49.81 1.48 +-19. 54.6 2.07 +-9. \END; /* Data scanned from Fig.7, p1458 in reference by CAJaD */ /* '189' Uncertainty given by authors */ \\EXP,41; RCT=204PB(P,T)202PB; CHM=ELM'190'; /* '190' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,41; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'191'; /* '191' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=2.73MEV; J-PTY=6+; DELTA-THTC=0.25DEG'192'; /* '192' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'193'; /* '193' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 5.96 281. 6.72 310. 8.46 320. 10.41 325. 12.36 317. 15.52 249. 18.11 186. 20.11 136. 22.91 91.6 25.67 77.5 28.22 69.4 30.94 71.6 33.12 57.2 35.66 56.5 38.44 42. 41. 35. 45.75 25. 51.23 20.6 55.78 13.55 61.08 9.97 \END; /* Data scanned from Fig.7, p1458 in reference by CAJaD */ \\EXP,42; RCT=204PB(P,T)202PB; CHM=ELM'194'; /* '194' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,42; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'195'; /* '195' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=4.6MEV; J-PTY=6+; DELTA-THTC=0.25DEG'196'; /* '196' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'197'; /* '197' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'198' (DEG) (UB/SR) (%) 6.46 18.3 +-X 7.79 22.1 +-X 10.18 17.9 +-X 17.47 10.49 +-X 21.04 7.17 +-X 23.19 7.29 +-X 25.52 7.42 +-X 28.11 5.29 +-X 31.08 4.23 +-X 33.43 4.55 +-X 36.14 4.25 +-X 37.64 5.74 +-3. 40.67 3.21 +-4. 45.81 2.05 +-5. 50.94 1.49 +-5. \END; /* Data scanned from Fig.7, p1458 in reference by CAJaD */ /* '198' Uncertainty given by authors */ \\EXP,43; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'199'; /* '199' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,43; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'200'; /* '200' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=2.19MEV; J-PTY=7-; DELTA-THTC=0.25DEG'201'; /* '201' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'202'; /* '202' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 5.55 103.1 8.26 134.9 10.82 144.4 13. 144.7 15.73 139.3 18.46 122.2 20.84 100.3 23.58 74. 26.13 60.7 28.69 47.9 33.6 42.1 38.52 35. 43.82 18.8 48.38 14.29 53.49 10.56 58.6 7.11 63.7 5.19 \END; /* Data scanned from Fig.8, p1458 in reference by CAJaD */ \\EXP,44; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'203'; /* '203' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,44; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'204'; /* '204' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=4.56MEV; J-PTY=7-; DELTA-THTC=0.25DEG'205'; /* '205' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'206'; /* '206' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 5.88 61.9 7.88 73.8 10.8 74.8 13.19 66.4 15.57 62.2 18.69 52.3 20.71 44.6 23.65 39.6 25.85 33.3 28.42 29.5 33.75 19.3 38.71 13.65 43.69 7.59 48.27 7.02 53.92 7.73 58.53 4.84 63.84 4.3 \END; /* Data scanned from Fig.8, p1458 in reference by CAJaD */ \\EXP,45; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'207'; /* '207' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,45; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'208'; /* '208' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=4.9MEV; J-PTY=7-; DELTA-THTC=0.25DEG'209'; /* '209' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'210'; /* '210' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'211' (DEG) (UB/SR) (%) 6.12 17. +-X 8.27 20. +-X 11.33 19. +-X 13.5 18. +-X 15.85 14.93 +-X 18.74 13.79 +-X 21.48 8.98 +-X 23.63 9.48 +-X 26.36 6.88 +-3. 29.28 4.36 +-3. 33.41 4.8 +-5. 38.85 3. +-17. 43.81 1. +-50. 48.8 1.8 +-28. 53.87 1.2 +-40. 58.59 0.75 +-30. 63.1 0.68 +-40. \END; /* Data scanned from Fig.8, p1458 in reference by CAJaD */ /* '211' Uncertainty given by authors */ \\EXP,46; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'212'; /* '212' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,46; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'213'; /* '213' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=5.1MEV; J-PTY=7-; DELTA-THTC=0.25DEG'214'; /* '214' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'215'; /* '215' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'216' (DEG) (UB/SR) (%) 5.98 11.83 +-X 9.02 15.27 +-X 11.54 15.1 +-X 13.9 12.08 +-X 16.24 11.63 +-X 18.6 9.81 +-X 21.51 6.43 +-X 23.84 7.46 +-X 25.86 5.58 +-3. 28.56 4.65 +-6. 33.61 4.2 +-12. 38.86 3.4 +-15. 43.43 1.4 +-40. 48.65 1.5 +-40. 53.37 0.91 +-29. 58.63 0.56 +-50. 63.31 0.53 +-50. \END; /* Data scanned from Fig.8, p1458 in reference by CAJaD */ /* '216' Uncertainty given by authors */ \\EXP,47; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'217'; /* '217' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,47; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'218'; /* '218' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=2.27MEV; J-PTY=7-; DELTA-THTC=0.25DEG'219'; /* '219' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'220'; /* '220' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 6.28 120.1 8.81 142.9 11.36 141. 13.36 130.2 15.92 110.9 18.47 108. 21.4 83.8 23.97 65.9 25.8 58.4 28.54 50.4 33.67 32.4 38.96 24.8 43.54 15.98 48.85 11.29 53.42 8.2 58.71 6.36 63.63 6.11 \END; /* Data scanned from Fig.8, p1458 in reference by CAJaD */ \\EXP,48; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'221'; /* '221' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,48; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'222'; /* '222' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=4.1MEV; J-PTY=7-; DELTA-THTC=0.25DEG'223'; /* '223' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'224'; /* '224' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 5.65 48.2 8.35 66.4 10.34 69.2 12.71 71.1 15.99 64.9 18.18 57.6 20.91 54. 23.84 44.3 25.86 36.3 28.23 30.2 33.92 17.1 38.85 12.93 48.17 7.63 53.48 5.41 58.79 3.31 \END; /* Data scanned from Fig.8, p1458 in reference by CAJaD */ \\EXP,49; RCT=204PB(P,T)202PB; CHM=ELM'225'; /* '225' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,49; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'226'; /* '226' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=4.0MEV; J-PTY=7-; DELTA-THTC=0.25DEG'227'; /* '227' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'228'; /* '228' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'229' (DEG) (UB/SR) (%) 6.28 19.2 +-X 7.57 15.52 +-X 9.91 20.1 +-X 14.45 20.1 +-X 17.74 16.9 +-X 19.76 13.3 +-X 22.51 10.17 +-X 25.25 8.67 +-X 27.65 6.03 +-X 29.63 7.1 +-X 32.04 4.43 +-X 34.58 4.88 +-X 37.13 4.21 +-X 39.89 2.97 +-X 44.97 3.28 +-X 49.35 2.8 +-X 55.03 1.66 +-X 59.96 1.414 +-5. \END; /* Data scanned from Fig.8, p1458 in reference by CAJaD */ /* '229' Uncertainty given by authors */ \\EXP,50; RCT=204PB(P,T)202PB; CHM=ELM'230'; /* '230' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,50; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'231'; /* '231' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=2.3MEV; J-PTY=7-; DELTA-THTC=0.25DEG'232'; /* '232' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'233'; /* '233' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'234' (DEG) (UB/SR) (%) 5.32 38.3 +-X 6.77 40.5 +-X 9.88 32.3 +-X 12.41 38. +-X 17.34 32.4 +-X 19.54 26.2 +-X 21.9 26.6 +-X 24.67 16.6 +-X 27.4 15.38 +-X 29.78 12.26 +-X 31.98 10.18 +-X 34.91 8.34 +-X 37.11 6.56 +-X 39.85 5.9 +-X 44.82 2.91 +-4. 49.53 3.52 +-X 54.83 2.59 +-X \END; /* Data scanned from Fig.8, p1458 in reference by CAJaD */ /* '234' Uncertainty given by authors */ \\EXP,51; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'235'; /* '235' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,51; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'236'; /* '236' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=5.8MEV; J-PTY=8+; DELTA-THTC=0.25DEG'237'; /* '237' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'238'; /* '238' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 5.84 22.6 8.55 20.7 10.71 20.7 13.96 20.9 16.83 22.7 19. 21.8 22.43 19.9 23.51 20.2 26.44 14.33 28.97 13.78 34.12 6.35 44.11 3.48 44.82 3.71 49.18 2.93 53.68 2.9 58.99 1.605 64.21 1.585 \END; /* Data scanned from Fig.9, p1459 in reference by CAJaD */ \\EXP,52; RCT=204PB(P,T)202PB; CHM=ELM'239'; /* '239' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,52; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'240'; /* '240' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=3.2MEV; J-PTY=8+; DELTA-THTC=0.25DEG'241'; /* '241' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'242'; /* '242' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 6.54 49.2 7.78 57.6 10.16 44.5 12.67 49.6 14.83 49.1 17.73 43.2 20.25 45.6 22.79 37.7 25.33 34.9 27.7 28.8 30.42 24.7 32.68 11.79 34.88 9.47 37.79 7.72 40.47 8.93 45.25 4.5 50.64 5.1 55.75 3.12 60.79 3.23 \END; /* Data scanned from Fig.9, p1459 in reference by CAJaD */ \\EXP,53; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'243'; /* '243' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,53; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'244'; /* '244' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=2.66MEV; J-PTY=9-; DELTA-THTC=0.25DEG'245'; /* '245' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'246'; /* '246' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 6.27 113.2 8.66 116.3 10.88 114.7 13.64 111.7 16.22 120.9 17.33 132.6 19.35 143.5 20.83 151.2 23.78 172. 26.35 145.3 29.12 132.4 33.73 66.7 39.08 34.9 41.47 28.6 44.24 30.2 49.22 26.1 54.19 17.3 59.9 15.38 64.33 12.12 \END; /* Data scanned from Fig.10, p1459(left) in reference by CAJaD */ \\EXP,54; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'247'; /* '247' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,54; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'248'; /* '248' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=3.96MEV; J-PTY=9-; DELTA-THTC=0.25DEG'249'; /* '249' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'250'; /* '250' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 6.76 60.2 9.16 55.5 11.92 52.6 15.06 52.6 17.09 48.5 19.85 49.8 21.88 46.5 25.2 44.7 27.6 41.2 29.82 31.4 34.62 19.3 39.98 13.97 44.96 9.57 49.95 6.46 54.57 4.37 60.11 3.2 64.91 2.48 \END; /* Data scanned from Fig.10, p1459(left) in reference by CAJaD */ \\EXP,55; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'251'; /* '251' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,55; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'252'; /* '252' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=6.2MEV; J-PTY=9-; DELTA-THTC=0.25DEG'253'; /* '253' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'254'; /* '254' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 6.45 58.9 9.22 53.5 11.98 52. 14.93 52.6 16.77 47.8 19.72 49.7 22.12 46.4 25.25 43.3 27.1 39.9 29.49 30.8 34.65 18.6 39.82 13.59 44.61 9.28 49.4 6.33 54.38 4.15 59.72 3.16 64.88 2.4 \END; /* Data scanned from Fig.10, p1459(left) in reference by CAJaD */ \\EXP,56; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'255'; /* '255' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,56; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'256'; /* '256' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=5.7MEV; J-PTY=9-; DELTA-THTC=0.25DEG'257'; /* '257' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'258'; /* '258' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'259' (DEG) (UB/SR) (%) 5.12 34.5 +-X 7.52 30.2 +-X 10.1 23.5 +-X 12.32 25.4 +-X 15.46 21.4 +-X 17.68 23.2 +-X 20.27 20.8 +-X 23.04 20. +-X 25.26 20.6 +-X 28.03 18.8 +-X 32.82 13.81 +-X 38.35 7.38 +-X 43.14 4.69 +-3. 47.93 3.4 +-15. 52.55 3.06 +-3. 58.08 2. +-15. 63.25 1.73 +-14. \END; /* Data scanned from Fig.10, p1459(left) in reference by CAJaD */ /* '259' Uncertainty given by authors */ \\EXP,57; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'260'; /* '260' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,57; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'261'; /* '261' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=2.21MEV; J-PTY=9-; DELTA-THTC=0.25DEG'262'; /* '262' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'263'; /* '263' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 4.98 106. 8.11 98. 10.32 95.5 12.35 95.6 15.3 111.1 17.33 104. 20.09 131. 23.23 140.4 24.88 127.9 27.65 119.7 33.55 64.6 38.16 35.3 43.31 25.6 48.48 18.3 52.9 17.4 58.25 12.8 62.86 9.93 \END; /* Data scanned from Fig.10, p1459(left) in reference by CAJaD */ \\EXP,58; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'264'; /* '264' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,58; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'265'; /* '265' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=5.1MEV; J-PTY=9-; DELTA-THTC=0.25DEG'266'; /* '266' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'267'; /* '267' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'268' (DEG) (UB/SR) (%) 4.28 4.46 +-6. 7.08 7.5 +-8. 9.82 2.9 +-24. 12.43 5.8 +-14. 14.82 3.6 +-19. 16.86 4.5 +-18. 19.28 6.8 +-7. 21.87 6.2 +-5. 24.64 5.76 +-5. 27.23 5.68 +-4. 32.39 4.2 +-17. 37.38 3.2 +-22. 39.2 1.8 +-28. 42.15 1.6 +-25. \END; /* Data scanned from Fig.10, p1459(left) in reference by CAJaD */ /* '268' Uncertainty given by authors */ \\EXP,59; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'269'; /* '269' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,59; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'270'; /* '270' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=5.52MEV; J-PTY=9-; DELTA-THTC=0.25DEG'271'; /* '271' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'272'; /* '272' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 8.01 32.3 9.5 30.2 12.3 32.3 15.09 31. 17.88 37.4 20.13 36.9 22.54 42.2 25.34 37.4 27.76 42.2 30.37 32.2 35.58 18.8 40.98 11.76 43.03 9.36 45.83 10.01 50.67 7.75 56.26 5.54 61.1 4.97 \END; /* Data scanned from Fig.10(right), p1459 in reference by CAJaD */ \\EXP,60; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'273'; /* '273' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,60; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'274'; /* '274' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=5.91MEV; J-PTY=9-; DELTA-THTC=0.25DEG'275'; /* '275' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'276'; /* '276' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 7.64 10.65 9.69 14.14 12.48 12.69 15.46 19. 17.33 18.5 21.8 19. 23.66 19.3 24.59 18.5 28.88 18.3 30.18 17.1 35.77 9.69 40.43 7.2 46.01 3.97 50.86 4.87 55.52 3.2 60.55 3.47 65.2 2.48 \END; /* Data scanned from Fig.10(right), p1459 in reference by CAJaD */ \\EXP,61; RCT=204PB(P,T)202PB; CHM=ELM'277'; /* '277' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,61; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'278'; /* '278' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=2.17MEV; J-PTY=9-; DELTA-THTC=0.25DEG'279'; /* '279' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'280'; /* '280' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 7.45 104.2 8.57 108.6 11.36 114.9 13.79 133.4 19. 132.3 21.03 127.3 23.85 108.8 26.64 109.1 29.43 95.7 32.03 82.8 34.65 57.1 36.51 42.7 38.75 31.9 41.36 26.9 46.39 20.7 51.42 16.5 56.45 11.29 61.29 10.33 \END; /* Data scanned from Fig.10(right), p1459 in reference by CAJaD */ \\EXP,62; RCT=204PB(P,T)202PB; CHM=ELM'281'; /* '281' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,62; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'282'; /* '282' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=5.2MEV; J-PTY=9-; DELTA-THTC=0.25DEG'283'; /* '283' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'284'; /* '284' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 6.52 17.4 8.38 19.4 10.62 15.86 15.83 12.3 18.63 15.45 21.05 15.66 24.22 24.4 26.27 16.5 28.88 14.26 31.3 10.34 33.91 8.12 35.95 4.21 38.38 3.4 40.61 3.63 46.2 2.93 51.6 2.93 61.09 1.91 \END; /* Data scanned from Fig.10(right), p1459 in reference by CAJaD */ \\EXP,63; RCT=204PB(P,T)202PB; CHM=ELM'285'; /* '285' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,63; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'286'; /* '286' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=5.3MEV; J-PTY=9-; DELTA-THTC=0.25DEG'287'; /* '287' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'288'; /* '288' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 6.33 21.5 7.82 18.3 10.25 18.8 15.46 18.1 17.88 18.1 20.49 20.5 23.29 18.4 25.89 15.47 28.69 16.8 30.74 13.19 33.35 8.6 35.58 5.92 40.43 3.92 45.83 3. 50.67 2.59 55.89 2.15 61.1 2.07 \END; /* Data scanned from Fig.10(right), p1459 in reference by CAJaD */ \\EXP,64; RCT=208PB(P,T)206PB; CHM=ELM; PHYS-FORM=SLD'289'; /* '289' Metallic foil */ THK-TGT=4MG/CM**2; \\DATA,64; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'290'; /* '290' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=206PB; EXC-ENGY=5.41MEV; J-PTY=11-; DELTA-THTC=0.25DEG'291'; /* '291' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'292'; /* '292' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA (DEG) (UB/SR) 9.3 28.3 13.4 32.4 27.5 24.1 31.7 21.7 34.8 23. 43. 27.1 50. 30.3 57.1 27.7 65.4 18.4 73.3 10.46 80.4 6.95 88.2 6.2 95.8 4.35 \END; /* Data scanned from Fig.11, p1462 in reference by CAJaD */ \\EXP,65; RCT=206PB(P,T)204PB; CHM=ELM; PHYS-FORM=SLD'293'; /* '293' Metallic foil */ THK-TGT=5MG/CM**2; \\DATA,65; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'294'; /* '294' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=204PB; EXC-ENGY=4.85MEV; J-PTY=11-; DELTA-THTC=0.25DEG'295'; /* '295' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'296'; /* '296' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'297' (DEG) (UB/SR) (%) 6.29 19.4 +-2.1 8.72 22.1 +-1.8 11.22 15.63 +-1.9 13.84 16.03 +-1.9 16.14 11.8 +-1.9 18.24 13.23 +-1.9 20.88 10.92 +-1.8 23.01 8.57 +-1.9 25.62 10.79 +-1.9 28.06 13.75 +-1.9 33.12 18.2 +-1.6 38.39 18.2 +-1.6 40.85 17.8 +-1.7 43.32 14.66 +-1.8 48.08 10.38 +-1.8 53.04 6.14 +-1.8 58.5 4.24 +-5. 63.6 3.68 +-5. 69.08 2.18 +-11. \END; /* Data scanned from Fig.11, p1462 in reference by CAJaD */ /* '297' Uncertainty given by authors */ \\EXP,66; RCT=204PB(P,T)202PB; CHM=ELM'298'; /* '298' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,66; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'299'; /* '299' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=4.4MEV; J-PTY=11-; DELTA-THTC=0.25DEG'300'; /* '300' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'301'; /* '301' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'302' (DEG) (UB/SR) (%) 17.21 11. +-1.8 22.52 6.42 +-2.6 24.97 6.51 +-1.8 27.44 5.23 +-1.9 29.87 7.6 +-1.8 32.53 5.52 +-1.8 35.15 6.12 +-1.8 37.25 6.53 +-1.8 40.05 6.79 +-1.9 45.55 3.35 +-2.1 50.1 3.92 +-1.8 55.62 1.37 +-10. \END; /* Data scanned from Fig.11, p1462 in reference by CAJaD */ /* '302' Uncertainty given by authors */ \\EXP,67; RCT=204PB(P,T)202PB; CHM=ELM'303'; /* '303' Prepared by centrifugal settling of PbO */ PHYS-FORM=SLD; THK-TGT=2MG/CM**2; BAC=MYLAR; \\DATA,67; INC-ENGY-LAB=51.9MEV; SYS-ERR=<20%'304'; /* '304' Error of the absolute cross section of the ground state transition is estimated to be less than 20%, where the main part comes from the uncertainty of the solid angle of each counter on the focal plane of the magnetic spectrograph. */ EMT=T; RSD=202PB; EXC-ENGY=4.5MEV; J-PTY=11-; DELTA-THTC=0.25DEG'305'; /* '305' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.9%'306'; /* '306' Data-point reader uncertainty */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'307' (DEG) (UB/SR) (%) 22.21 4.4 +-11. 27.28 5.36 +-1.9 29.9 6.42 +-2. 32.34 8.19 +-1.8 34.45 7.2 +-1.8 37.43 7.58 +-1.8 39.91 5.72 +-1.9 45.22 3.17 +-1.9 50.16 2.3 +-2.2 55.28 1.55 +-4. \END; /* Data scanned from Fig.11, p1462 in reference by CAJaD */ /* '307' Uncertainty given by authors */ \\END;