/* 2005-12-19 File is generated by HENDEL. */ \\BIB,1[9; D#=D1540; TITLE=/ Energy levels of 60Co studied by the (d,p) reaction /; PURPOSE=/ To obtain certain spectroscopic informations using the DWBA analysis in place of the PWBA /; ATH=(S.UEHARA'1'); INST-ATH=(2JPNKYU'1'); /* '1' Department of Physics */ REF=JPJ; VLP=38(1975)936; RCTS=(59CO(D,D)59CO, 59CO(D,P)60CO); PHQS=(ANGL-DSTRN, SPEC-FCTR, OPT-POTL-PARA); \\EXP,1[9; /* 2005-09-15 : Converted, Tt + Sr + On. Converted to EXFOR E1540 */ /* 2005-11-07 : Altered, Ot + Sr. Re-digitized */ CHM=ELM; PHYS-FORM=SLD; THK-TGT=[0.06MG/CM**2; BAC=C; POL-TGT=0%; ALGN-TGT=0%; ACC=X'2'; /* '2' Accelerator, Electrostatic accelerator */ INST-ACC=2JPNKYU; INC-ENGY-LAB=6.5MEV; POL-PRJ=0%; COINC=NO; ANT-COINC=NO; DET-SYS=(SBD'3',X'4'); /* '3' To detect particle emitted from reaction */ /* '4' Scattering chamber */ /* Experimental Method: - Beam current integrated */ \\EXP,1; RCT=59CO(D,D)59CO; RTY=ELA-SCATT; PHQ=ANGL-DSTRN; DET-PARTCL=D; ANL=OPT-MODEL; \\DATA,1; INC-ENGY-LAB=6.5MEV; SYS-ERR=5%'5'; /* '5' Total systematic error. Accuracy of absolute cross section */ EMT=D; \DATA; THTC RUTH-RATIO'6' DELTA-RUTH-RATIO'6,7' (DEG) (NODIM) (NODIM) 9.569E+00 1.002E+00 +-4.302E-02 1.557E+01 1.135E+00 +-4.378E-02 2.051E+01 9.872E-01 +-2.949E-02 2.571E+01 1.003E+00 +-3.868E-02 3.108E+01 9.810E-01 +-4.213E-02 3.645E+01 9.476E-01 +-3.655E-02 4.160E+01 8.740E-01 +-2.990E-02 4.676E+01 7.994E-01 +-2.735E-02 5.156E+01 7.690E-01 +-3.302E-02 5.691E+01 7.122E-01 +-2.747E-02 6.172E+01 6.997E-01 +-2.394E-02 6.671E+01 6.674E-01 +-2.574E-02 7.189E+01 6.502E-01 +-2.508E-02 7.727E+01 6.495E-01 +-2.505E-02 8.244E+01 6.092E-01 +-2.350E-02 8.742E+01 5.762E-01 +-2.223E-02 9.205E+01 5.614E-01 +-2.167E-02 9.742E+01 5.538E-01 +-2.136E-02 1.022E+02 5.441E-01 +-2.098E-02 1.076E+02 5.189E-01 +-2.229E-02 \END; /* Data scanned from Fig.2, p937 in reference */ /* '6' On the assumption that the cross section at 10 deg. is equal to the Rutherford cross section */ /* '7' Statistical error : Scanned from upper errors */ \\EXP,2; RCT=59CO(D,P)60CO; PHQ=ANGL-DSTRN; DET-PARTCL=P; ERS-DET=18KEV'8'; /* '8' For 12 MeV protons */ ANL=DWBA; \\DATA,2; INC-ENGY-LAB=6.5MEV; SYS-ERR=10%'9'; /* '9' Total systematic error. Accuracy of absolute cross section */ EMT=P; EXC-ENGY=0.0MEV; DELTA-EXC-ENGY=5KEV; J-PTY=5+; TRNSF-L=1'10'; /* '10' Transferred angular momentum (L) */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'11' (DEG) (MB/SR) (MB/SR) 2.504E+01 1.164E+00 +-7.060E-02 3.022E+01 8.234E-01 +-4.993E-02 3.511E+01 6.637E-01 +-4.025E-02 3.971E+01 5.750E-01 +-3.089E-02 4.518E+01 6.061E-01 +-2.840E-02 5.065E+01 7.001E-01 +-3.280E-02 5.525E+01 7.575E-01 +-3.549E-02 6.014E+01 7.479E-01 +-2.994E-02 6.532E+01 5.873E-01 +-2.351E-02 7.022E+01 4.860E-01 +-2.277E-02 7.540E+01 3.918E-01 +-1.836E-02 8.029E+01 3.056E-01 +-2.066E-02 8.489E+01 2.753E-01 +-1.290E-02 9.065E+01 2.666E-01 +-1.432E-02 9.496E+01 2.433E-01 +-1.307E-02 1.001E+02 2.402E-01 +-1.291E-02 1.105E+02 2.109E-01 +-1.133E-02 1.200E+02 1.522E-01 +-8.175E-03 1.304E+02 1.380E-01 +-6.468E-03 1.407E+02 1.355E-01 +-8.214E-03 \END; /* Data scanned from Fig.3, p938 in reference */ /* '11' Statistical error : Scanned from upper errors */ \\EXP,3; RCT=59CO(D,P)60CO; PHQ=ANGL-DSTRN; DET-PARTCL=P; ERS-DET=18KEV'12'; /* '12' For 12 MeV protons */ ANL=DWBA; \\DATA,3; INC-ENGY-LAB=6.5MEV; SYS-ERR=10%'13'; /* '13' Total systematic error. Accuracy of absolute cross section */ EMT=P; EXC-ENGY=0.288MEV; DELTA-EXC-ENGY=5KEV; J-PTY=(3+,4+); TRNSF-L=(1,3)'14'; /* '14' Transferred angular momentum (L) */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'15' (DEG) (MB/SR) (MB/SR) 2.559E+01 4.522E-01 +-2.341E-02 3.068E+01 3.955E-01 +-2.047E-02 3.529E+01 3.234E-01 +-1.674E-02 4.014E+01 3.129E-01 +-1.620E-02 4.548E+01 3.238E-01 +-1.676E-02 5.081E+01 3.295E-01 +-1.512E-02 5.542E+01 3.242E-01 +-1.678E-02 6.028E+01 2.999E-01 +-1.201E-02 6.537E+01 2.885E-01 +-1.324E-02 6.998E+01 2.386E-01 +-1.235E-02 7.580E+01 2.195E-01 +-1.266E-02 8.065E+01 1.805E-01 +-9.342E-03 8.526E+01 1.756E-01 +-8.056E-03 9.036E+01 1.661E-01 +-7.621E-03 9.594E+01 1.681E-01 +-7.712E-03 1.001E+02 1.478E-01 +-6.782E-03 1.100E+02 1.112E-01 +-5.101E-03 1.204E+02 1.113E-01 +-4.457E-03 1.304E+02 8.856E-02 +-4.585E-03 1.395E+02 7.041E-02 +-4.374E-03 \END; /* Data scanned from Fig.3, p938 in reference */ /* '15' Statistical error : Scanned from upper errors */ \\EXP,4; RCT=59CO(D,P)60CO; PHQ=ANGL-DSTRN; DET-PARTCL=P; ERS-DET=18KEV'16'; /* '16' For 12 MeV protons */ ANL=DWBA; \\DATA,4; INC-ENGY-LAB=6.5MEV; SYS-ERR=10%'17'; /* '17' Total systematic error. Accuracy of absolute cross section */ EMT=P; EXC-ENGY=1.813MEV; DELTA-EXC-ENGY=10KEV; J-PTY=6+; TRNSF-L=3'18'; /* '18' Transferred angular momentum (L) */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'19' (DEG) (MB/SR) (MB/SR) 2.546E+01 3.634E-01 +-2.349E-02 3.553E+01 4.502E-01 +-1.920E-02 4.033E+01 4.870E-01 +-2.342E-02 4.580E+01 4.922E-01 +-2.099E-02 5.035E+01 4.796E-01 +-2.307E-02 5.492E+01 4.899E-01 +-2.356E-02 6.000E+01 4.708E-01 +-2.225E-02 6.483E+01 4.602E-01 +-2.173E-02 6.965E+01 3.473E-01 +-1.481E-02 7.490E+01 3.584E-01 +-1.528E-02 7.993E+01 3.959E-01 +-1.904E-02 8.528E+01 3.199E-01 +-1.203E-02 9.038E+01 3.458E-01 +-1.287E-02 9.464E+01 2.529E-01 +-1.216E-02 1.004E+02 3.306E-01 +-1.882E-02 1.104E+02 2.794E-01 +-1.344E-02 1.202E+02 2.429E-01 +-1.147E-02 1.300E+02 1.784E-01 +-7.563E-03 1.398E+02 1.340E-01 +-5.714E-03 \END; /* Data scanned from Fig.3, p938 in reference */ /* '19' Statistical error : Scanned from upper errors */ \\EXP,5; RCT=59CO(D,P)60CO; PHQ=ANGL-DSTRN; DET-PARTCL=P; ERS-DET=18KEV'20'; /* '20' For 12 MeV protons */ ANL=DWBA; \\DATA,5; INC-ENGY-LAB=6.5MEV; SYS-ERR=10%'21'; /* '21' Total systematic error. Accuracy of absolute cross section */ EMT=P; EXC-ENGY=2.137MEV; DELTA-EXC-ENGY=10KEV; TRNSF-L=(2,4)'22'; /* '22' Transferred angular momentum (L) */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'23' (DEG) (MB/SR) (MB/SR) 2.575E+01 1.151E-01 +-1.902E-02 3.072E+01 1.305E-01 +-1.631E-02 3.541E+01 1.591E-01 +-2.092E-02 4.044E+01 1.491E-01 +-1.784E-02 4.537E+01 1.644E-01 +-1.692E-02 5.029E+01 1.638E-01 +-1.757E-02 5.589E+01 1.720E-01 +-1.628E-02 6.021E+01 1.729E-01 +-1.825E-02 6.515E+01 1.538E-01 +-1.435E-02 7.068E+01 1.695E-01 +-1.603E-02 7.565E+01 1.552E-01 +-9.261E-03 8.055E+01 1.657E-01 +-1.431E-02 8.548E+01 1.469E-01 +-1.757E-02 9.041E+01 1.607E-01 +-1.258E-02 9.567E+01 1.595E-01 +-1.510E-02 1.006E+02 1.457E-01 +-1.259E-02 1.105E+02 1.321E-01 +-1.034E-02 1.203E+02 1.095E-01 +-7.680E-03 1.305E+02 7.233E-02 +-8.046E-03 1.407E+02 7.178E-02 +-7.985E-03 \END; /* Data scanned from Fig.3, p938 in reference */ /* '23' Statistical error : Scanned from upper errors */ \\EXP,6; RCT=59CO(D,P)60CO; PHQ=ANGL-DSTRN; DET-PARTCL=P; ERS-DET=18KEV'24'; /* '24' For 12 MeV protons */ ANL=DWBA; \\DATA,6; INC-ENGY-LAB=6.5MEV; SYS-ERR=10%'25'; /* '25' Total systematic error. Accuracy of absolute cross section */ EMT=P; EXC-ENGY=2.886MEV; DELTA-EXC-ENGY=10KEV; J-PTY=(3-,4-); TRNSF-L=0'26'; /* '26' Transferred angular momentum (L) */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'27' (DEG) (MB/SR) (MB/SR) 2.538E+01 9.293E-02 +-2.865E-02 3.542E+01 1.436E-01 +-3.750E-02 4.572E+01 1.846E-01 +-2.272E-02 5.074E+01 1.976E-01 +-1.633E-02 5.577E+01 1.530E-01 +-1.674E-02 6.052E+01 1.598E-01 +-1.426E-02 6.554E+01 1.522E-01 +-1.769E-02 8.537E+01 7.069E-02 +-8.698E-03 9.066E+01 4.933E-02 +-8.844E-03 9.516E+01 2.991E-02 +-7.585E-03 1.002E+02 5.719E-02 +-7.826E-03 1.102E+02 4.297E-02 +-7.082E-03 1.203E+02 6.761E-02 +-1.067E-02 1.303E+02 4.635E-02 +-7.646E-03 1.401E+02 3.984E-02 +-6.289E-03 \END; /* Data scanned from Fig.3, p938 in reference */ /* '27' Statistical error : Scanned from upper errors */ \\EXP,7; RCT=59CO(D,P)60CO; PHQ=ANGL-DSTRN; DET-PARTCL=P; ERS-DET=18KEV'28'; /* '28' For 12 MeV protons */ ANL=DWBA; \\DATA,7; INC-ENGY-LAB=6.5MEV; SYS-ERR=10%'29'; /* '29' Total systematic error. Accuracy of absolute cross section */ EMT=P; EXC-ENGY=3.007MEV; DELTA-EXC-ENGY=10KEV; TRNSF-L=2'30'; /* '30' Transferred angular momentum (L) */ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'31' (DEG) (MB/SR) (MB/SR) 2.653E+01 9.449E-02 +-1.998E-02 3.080E+01 1.104E-01 +-1.454E-02 3.587E+01 1.339E-01 +-2.144E-02 4.094E+01 1.717E-01 +-2.504E-02 5.577E+01 1.264E-01 +-1.755E-02 6.056E+01 1.346E-01 +-1.679E-02 6.530E+01 1.039E-01 +-1.152E-02 7.034E+01 9.595E-02 +-1.468E-02 8.069E+01 9.438E-02 +-1.112E-02 8.575E+01 1.083E-01 +-1.202E-02 9.550E+01 6.216E-02 +-1.176E-02 1.005E+02 4.710E-02 +-7.541E-03 1.107E+02 8.496E-02 +-9.420E-03 1.204E+02 4.364E-02 +-6.675E-03 1.302E+02 3.035E-02 +-7.108E-03 1.398E+02 3.506E-02 +-6.634E-03 \END; /* Data scanned from Fig.3, p938 in reference */ /* '31' Statistical error : Scanned from upper errors */ \\EXP,8; RCT=59CO(D,P)60CO; PHQ=SPEC-FCTR; DET-PARTCL=P; ERS-DET=18KEV'32'; /* '32' For 12 MeV protons */ \\DATA,8; INC-ENGY-LAB=6.5MEV; SYS-ERR=10%'33'; /* '33' Total systematic error. Accuracy of absolute cross section */ EMT=P; \DATA; EXC-ENGY'34' TRNSF-L SPEC-FCTR'35' DSIGMA/DOMEGA'36' FLAG'37' (MEV) (NODIM) (NODIM) (MB/SR) (NODIM) 0 1 4.68 1.150 1. 0.059 1 2.53 0.640 1. 0.288 1 1.20 0.443 X X 3 7.80 X X 0.437 3 5.24 0.180 X 0.508 1 1.39 0.363 1. 0.542 3 4.82 0.130 X 0.616 1 2.47 0.722 1. 0.742 3 1.66 0.055 X 0.788 1 1.76 0.524 1. 1.010 1 3.65 1.030 1. 1.220 1 0.22 0.156 X X 3 3.33 X X 1.344 1 0.19 0.049 1. 1.390 1 0.29 0.215 X X 3 5.50 X X 1.460 1 0.22 0.087 1. 1.524 1 0.46 0.165 1. 1.649 1 0.08 0.056 X X 3 1.13 X X 1.717 X X 0.036 X 1.757 X X 0.020 X 1.813 3 16.90 0.500 X 1.857 1 0.35 0.124 1. 1.892 1 0.23 0.084 1. 1.926 1 0.14 0.060 1. 1.986 1 0.38 0.249 X X 3 4.20 X X 2.037 1 0.14 0.078 X X 3 1.14 X X 2.137 2 0.37 0.170 X X 4 8.19 X X 2.227 0 0.09 0.061 X 2.282 1 0.58 0.230 1. 2.313 2 0.27 0.061 X 2.356 0 0.15 0.194 X X 2 0.48 X X 2.432 X X 0.043 X 2.500 X X 0.030 X 2.531 X X 0.037 X 2.573 X X 0.034 X 2.600 2 0.47 0.110 X 2.660 X X 0.030 X 2.695 X X 0.036 X 2.766 0 0.19 0.215 X X 2 0.26 X X 2.846 0 0.26 0.432 X X 2 0.66 X X 2.886 0 0.23 0.197 X 3.007 2 0.54 0.140 X 3.061 X X 0.054 X 3.084 X X 0.083 X 3.117 X X 0.062 X 3.183 2 1.22 0.320 X 3.236 2 0.33 0.105 X 3.278 2 0.99 0.282 X 3.336 2 0.69 0.205 X 3.362 X X 0.075 X 3.411 X X 0.040 X 3.561 2 0.37 0.149 X X 4 3.39 X X 3.587 0 0.12 0.190 X X 4 3.02 X X 3.649 0 0.12 0.191 X X 2 0.27 X X 3.740 X X 0.103 X 3.825 2 0.28 0.100 X 3.867 0 0.13 0.160 X 3.908 0 0.08 0.125 X X 2 0.18 X X 3.986 X X 0.097 X 4.034 X X 0.125 X 4.109 0 0.10 0.122 X 4.209 0 0.07 0.281 X X 2 0.54 X X 4.272 0 0.08 0.230 X X 2 0.42 X X 4.366 X X 0.137 X 4.393 X X 0.680 X 4.454 0 0.14 0.256 X 4.505 X X 0.085 X 4.546 0 0.20 0.264 X 4.602 0 0.13 0.175 X 4.632 X X 0.085 X 4.667 X X 0.145 X 4.707 0 0.15 0.255 X 4.777 X X 0.139 X 4.833 X X 0.213 X 4.873 X X 0.100 X 4.926 X X 0.079 X 4.958 X X 0.155 X 4.994 X X 0.140 X \END; /* Data taken from Table 1, p939-940 in reference */ /* '34' Uncertainties of Excitation energies are estimated within 5 keV below 1 MeV, within 10 keV above 1 MeV. */ /* '35' Spectroscopic strength (2J+1)S */ /* '36' Cross sections at the second maximum in the angular distributions */ /* '37' FLAG(1.) Maximum of the experimental cross section was not observed because of absence of the measurement for angles <25 deg. */ \\EXP,9; RCT=59CO(D,D)59CO; RTY=ELA-SCATT; PHQ=OPT-POTL-PARA; DET-PARTCL=D; \\DATA,9; INC-ENGY-LAB=6.5MEV; SYS-ERR=5%'38'; /* '38' Total systematic error. Accuracy of absolute cross section */ EMT=D; POTL-FORM=/ Uc(X) -V*f(X,Rr,Ar) -i*W*f(X,Riv,Aiv) : Uniform charge of radius Rc*A**(1/3) : f(X,R,A)=1/(1+exp((X-R*A**(1/3))/A) /; \DATA; V RR AR RC WV RIV AIV (MEV) (FM) (FM) (FM) (MEV) (FM) (FM) 75.0 1.15 0.70 1.15 20.0 1.30 0.66 \END; /* Data taken from Table 2, p940 in reference */ \\END;