/* 2006-04-11 File is generated by HENDEL. */ \\BIB,1[15; D#=D1647; TITLE=/ Measurements of 10Be and 26Al production cross sections with 12 GeV protons by accelerator mass spectrometry /; PURPOSE=/ To discuss the production mechanisms of 10Be and 26Al by spallation and fragmentation in high-energy nuclear reactions /; ATH=(S.SHIBATA'1', M.IMAMURA'1', H.NAGAI'2', K.KOBAYASHI'3', K.SAKAMOTO'4', M.FURUKAWA'5', I.FUJIWARA'6'); INST-ATH=(2JPNINS'1', 2JPNJPN'2', 2JPNTOK'3', 2JPNKNZ'4', 2JPNNAG'5', 2JPNJPN'6'); /* '2' College of Humanities and Sciences, Nihon University, Tokyo */ /* '3' Recearch Center for Nuclear Science and Technology */ /* '4' Department of Chemistry */ /* '5' Department of Chemistry */ /* '6' School of Economics, Otemon Gakuin University, Ibaragi, Osaka */ REF=PR/C; VLP=48(1993)2617; RCTS=(27AL(P,X)10BE, 27AL(P,X)26AL, FE(P,X)10BE, FE(P,X)26AL, 59CO(P,X)10BE, 59CO(P,X)26AL, NI(P,X)10BE, NI(P,X)26AL, CU(P,X)10BE, ZN(P,X)10BE, ZN(P,X)26AL, AG(P,X)10BE, AG(P,X)26AL, 197AU(P,X)10BE, 197AU(P,X)26AL); PHQS=XSECTN; \\EXP,1[15; /* 2003-08-20 : Converted, Am + On. Data converted to EXFOR E1647 */ PHQ=XSECTN; CHM=ELM; PHYS-FORM=SLD; BAC=X'7'; /* '7' Each target foil was guarded on both sides with identical foils in order to compensate for recoil losses and to prevent cross-contamination between the targets. */ POL-TGT=0%; ALGN-TGT=0%; ACC=(SYN'8',VDGT'9'); /* '8' For Activation */ /* '9' For Accelerator mass spectrometry */ INST-ACC=(2JPNKEK'8',2JPNTOK'9'); /* '9' Research Center for Nuclear Science and Technology */ INC-ENGY-LAB=12GEV; BEAM-INTNSTY=2.62e+11PPS; POL-PRJ=0%; COINC=NO; ANT-COINC=NO; DET-SYS=SBD'10'; /* '10' Used in accelerator mass spectrometry */ ANL=X'11'; /* '11' Universal formula for target mass dependence of production cross section [X.Campi et al., Phys. Lett. 138B(1984)353]. */ /* Experimental Method: - Activation (Irradiation for 10 min) - Chemical separation (Separated using 200 micro-gram of Be and 500 micro-gram of Al carriers) - Accelerator mass spectrometry (Isotopic ratios of 10Be/9Be and 26Al/27Al were determined by the AMS system using an internal beam-monitor method) */ \\DATA,1[15; TOT-ERR=X%'12'; /* '12' Uncertainties due to the beam-intensity calibration not included */ SYS-ERR=([10%'13',1%'14'); /* '13' Uncertainties due to the beam-intensity calibration */ /* '14' Uncertainties in the amounts of beryllium and aluminium carriers added */ \\EXP,1; /* Related references - B.Dittrich et al., RCA, 50(1990)11. Reference with which data agree. See also EXFOR A0479.004. - B.Dittrich et al., NIM/B, 52(1990)588. Reference with which data agree. See also EXFOR O0281.004. */ RCT=27AL(P,X)10BE; THK-TGT=5.20MG/CM**2; DET-PARTCL=10BE; \\DATA,1; SYS-ERR=1.5%'15'; /* '15' Uncertainty in the absolute isotopic ratios for 10Be standard samples in AMS analysis */ \DATA; INC-ENGY-LAB XSECTN DELTA-XSECTN (GEV) (MB) (MB) 12 2.47 +-0.16 \END; /* Data taken from Table I, p2620 in reference */ \\EXP,2; /* Related references - B.Dittrich et al., RCA, 50(1990)11. Reference with which data agree. See also EXFOR A0479.009. - B.Dittrich et al., NIM/B, 52(1990)588. Reference with which data agree. See also EXFOR O0281.009. - M.Furukawa et al., NP/A, 174(1971)539. Reference with which data agree. See also EXFOR O0972.003. - R.J.Schneider et al., NIM/B, 29(1987)271. Reference with which data agree. See also EXFOR C0199.003. */ RCT=27AL(P,X)26AL; THK-TGT=5.20MG/CM**2; DET-PARTCL=26AL; \\DATA,2; SYS-ERR=2%'16'; /* '16' Uncertainty in the absolute isotopic ratios for 26Al standard samples in AMS analysis */ \DATA; INC-ENGY-LAB XSECTN DELTA-XSECTN (GEV) (MB) (MB) 12 20.1 +-1.6 \END; /* Data taken from Table I, p2620 in reference */ \\EXP,3; /* Related references - B.Dittrich et al., RCA, 50(1990)11. (Data from this reference plotted together). See also EXFOR A0479.007. - B.Dittrich et al., NIM/B, 52(1990)588. (Data from this reference plotted together). See also EXFOR O0281.007. - M.Honda et al., NP, 51(1964)363. (Data from this reference plotted together). See also EXFOR C0226.002. - C.Perron et al., PR/C, 14(1976)1108. (Data from this reference plotted together). See also EXFOR O0085.022. */ RCT=FE(P,X)10BE; THK-TGT=7.52MG/CM**2; DET-PARTCL=10BE; \\DATA,3; SYS-ERR=1.5%'17'; /* '17' Uncertainty in the absolute isotopic ratios for 10Be standard samples in AMS analysis */ \DATA; INC-ENGY-LAB XSECTN DELTA-XSECTN (GEV) (MB) (MB) 12 2.95 +-0.33 \END; /* Data taken from Table I, p2620 in reference */ \\EXP,4; /* Related references - B.Dittrich et al., RCA, 50(1990)11. (Data from this reference plotted together). See also EXFOR A0479.011. - B.Dittrich et al., NIM/B, 52(1990)588. (Data from this reference plotted together). See also EXFOR O0281.011. - M.Honda et al., PR, 118(1960)1618. . See also EXFOR C0235.019. */ RCT=FE(P,X)26AL; THK-TGT=7.52MG/CM**2; DET-PARTCL=26AL; \\DATA,4; SYS-ERR=2%'18'; /* '18' Uncertainty in the absolute isotopic ratios for 26Al standard samples in AMS analysis */ \DATA; INC-ENGY-LAB XSECTN DELTA-XSECTN (GEV) (MB) (MB) 12 2.02 +-0.22 \END; /* Data taken from Table I, p2620 in reference */ \\EXP,5; RCT=59CO(P,X)10BE; THK-TGT=8.36MG/CM**2; DET-PARTCL=10BE; \\DATA,5; SYS-ERR=1.5%'19'; /* '19' Uncertainty in the absolute isotopic ratios for 10Be standard samples in AMS analysis */ \DATA; INC-ENGY-LAB XSECTN DELTA-XSECTN (GEV) (MB) (MB) 12 3.83 +-0.36 \END; /* Data taken from Table I, p2620 in reference */ \\EXP,6; RCT=59CO(P,X)26AL; THK-TGT=8.36MG/CM**2; DET-PARTCL=26AL; \\DATA,6; SYS-ERR=2%'20'; /* '20' Uncertainty in the absolute isotopic ratios for 26Al standard samples in AMS analysis */ \DATA; INC-ENGY-LAB XSECTN DELTA-XSECTN (GEV) (MB) (MB) 12 1.80 +-0.25 \END; /* Data taken from Table I, p2620 in reference */ \\EXP,7; /* Related references - B.Dittrich et al., RCA, 50(1990)11. Reference with which data disagree (Data given in this reference are somewhat lower than the present work). See also EXFOR A0479.008. - B.Dittrich et al., NIM/B, 52(1990)588. Reference with which data disagree (Data given in this reference are somewhat lower than the present work). See also EXFOR O0281.008. - G.M.Raisbeck et al., PR/C, 12(1975)527. Reference with which data disagree (Data given in this reference are somewhat lower than the present work). See also EXFOR O0114.018. */ RCT=NI(P,X)10BE; THK-TGT=17.4MG/CM**2; DET-PARTCL=10BE; \\DATA,7; SYS-ERR=1.5%'21'; /* '21' Uncertainty in the absolute isotopic ratios for 10Be standard samples in AMS analysis */ \DATA; INC-ENGY-LAB XSECTN DELTA-XSECTN (GEV) (MB) (MB) 12 4.02 +-0.27 \END; /* Data taken from Table I, p2620 in reference */ \\EXP,8; /* Related references - B.Dittrich et al., RCA, 50(1990)11. Reference with which data disagree (Data given in this reference are slightly higher than the present work). See also EXFOR A0479.012. - B.Dittrich et al., NIM/B, 52(1990)588. Reference with which data disagree (Data given in this reference are slightly higher than the present work). See also EXFOR O0281.012. */ RCT=NI(P,X)26AL; THK-TGT=17.4MG/CM**2; DET-PARTCL=26AL; \\DATA,8; SYS-ERR=2%'22'; /* '22' Uncertainty in the absolute isotopic ratios for 26Al standard samples in AMS analysis */ \DATA; INC-ENGY-LAB XSECTN DELTA-XSECTN (GEV) (MB) (MB) 12 2.14 +-0.21 \END; /* Data taken from Table I, p2620 in reference */ \\EXP,9; RCT=CU(P,X)10BE; THK-TGT=9.06MG/CM**2; DET-PARTCL=10BE; \\DATA,9; SYS-ERR=1.5%'23'; /* '23' Uncertainty in the absolute isotopic ratios for 10Be standard samples in AMS analysis */ \DATA; INC-ENGY-LAB XSECTN DELTA-XSECTN (GEV) (MB) (MB) 12 4.14 +-0.42 \END; /* Data taken from Table I, p2620 in reference */ \\EXP,10; RCT=ZN(P,X)10BE; THK-TGT=58.1MG/CM**2; DET-PARTCL=10BE; \\DATA,10; SYS-ERR=1.5%'24'; /* '24' Uncertainty in the absolute isotopic ratios for 10Be standard samples in AMS analysis */ \DATA; INC-ENGY-LAB XSECTN DELTA-XSECTN (GEV) (MB) (MB) 12 4.57 +-0.23 \END; /* Data taken from Table I, p2620 in reference */ \\EXP,11; RCT=ZN(P,X)26AL; THK-TGT=58.1MG/CM**2; DET-PARTCL=26AL; \\DATA,11; SYS-ERR=2%'25'; /* '25' Uncertainty in the absolute isotopic ratios for 26Al standard samples in AMS analysis */ \DATA; INC-ENGY-LAB XSECTN DELTA-XSECTN (GEV) (MB) (MB) 12 1.84 +-0.12 \END; /* Data taken from Table I, p2620 in reference */ \\EXP,12; RCT=AG(P,X)10BE; THK-TGT=12.1MG/CM**2; DET-PARTCL=10BE; \\DATA,12; SYS-ERR=1.5%'26'; /* '26' Uncertainty in the absolute isotopic ratios for 10Be standard samples in AMS analysis */ \DATA; INC-ENGY-LAB XSECTN DELTA-XSECTN (GEV) (MB) (MB) 12 13.0 +-0.9 \END; /* Data taken from Table I, p2620 in reference */ \\EXP,13; RCT=AG(P,X)26AL; THK-TGT=12.1MG/CM**2; DET-PARTCL=26AL; \\DATA,13; SYS-ERR=2%'27'; /* '27' Uncertainty in the absolute isotopic ratios for 26Al standard samples in AMS analysis */ \DATA; INC-ENGY-LAB XSECTN DELTA-XSECTN (GEV) (MB) (MB) 12 0.994 +-0.195 \END; /* Data taken from Table I, p2620 in reference */ \\EXP,14; RCT=197AU(P,X)10BE; THK-TGT=39.3MG/CM**2; DET-PARTCL=10BE; \\DATA,14; SYS-ERR=1.5%'28'; /* '28' Uncertainty in the absolute isotopic ratios for 10Be standard samples in AMS analysis */ \DATA; INC-ENGY-LAB XSECTN DELTA-XSECTN (GEV) (MB) (MB) 12 41.3 +-2.0 \END; /* Data taken from Table I, p2620 in reference */ \\EXP,15; RCT=197AU(P,X)26AL; THK-TGT=39.3MG/CM**2; DET-PARTCL=26AL; \\DATA,15; SYS-ERR=2%'29'; /* '29' Uncertainty in the absolute isotopic ratios for 26Al standard samples in AMS analysis */ \DATA; INC-ENGY-LAB XSECTN DELTA-XSECTN (GEV) (MB) (MB) 12 1.12 +-0.14 \END; /* Data taken from Table I, p2620 in reference */ \\END;