/* 2006-02-24 File is generated by HENDEL. */ \\BIB,1[2; D#=D1722; TITLE=/ Reaction mechanism and characteristics of T20 in d+3He backward elastic scattering at intermediate energies /; ATH=(M.TANIFUJI'1', S.ISHIKAWA'1', Y.ISERI'2', T.UESAKA'3', N.SAKAMOTO'3', Y.SATOU'3', K.ITOH'3', H.SAKAI'3,4', A.TAMII'4', T.OHNISHI'4', K.SEKIGUCHI'4', K.YAKO'4', S.SAKODA'4', H.OKAMURA'5', K.SUDA'5', T.WAKASA'6'); INST-ATH=(2JPNHOS'1', 2JPNJPN'2', 2JPNIPC'3', 2JPNTOK'4', 2JPNSUU'5', 2JPNRCN'6'); /* '1' Department of Physics */ /* '2' Department of Physics, Chiba-Keizai College, Chiba */ /* '4' Department of Physics */ /* '5' Department of Physics */ REF=PR/C; VLP=61(2000)024602; RCTS=D(3HE,3HE)D; PHQS=(ANGL-DSTRN, TNSR-ANALPW'7'); /* '7' T(20) */ \\EXP,1[2; /* 2002-09-05 : Converted, Data converted to EXFOR E1722 */ /* 2004-11-25 : Altered, INSTITUTE, REFERENCE and heading of systematic error corrected */ RTY=(ELA-SCATT,POL-RCT); ENR=X%; CHM=ELM; PHYS-FORM=GAS; THK-TGT=XMG/CM**2'8'; /* '8' The size of target was 13mm(20mm) wide, 15mm(20mm)high, and 20mm(10mm)thick in the case of 270MeV(140,200MeV) measurement. The gas pressure is approximately 1 atm which was measured with Baratron gauge. */ POL-TGT=0%; ALGN-TGT=0%; ACC=CYC; INST-ACC=2JPNIPC; INC-ENGY-LAB=(140MEV, 200MEV, 270MEV); POL-PRJ=60[80%; ION-SOURCE=/ Polarized ion source (High-Intensity polarized ion source [H.Okamura et al., in polarized ion source and polarized gas targets, edited by L.W.Anderson and Willy Haeberli, AIP Conf.Proc.No.293(AIP, New York, 1994), P.84]) /; DET-PARTCL=3HE; COINC=NO; ANT-COINC=NO; DET-SYS=(MAG'9',MWDC,SCT'10'); /* '9' SMART [T.Ichihara et al., Nucl.Phys.A569(1994)287c]. */ /* '10' Plastic scintillator */ MONTR-RCT=/ , The beam polarization was measured with a polarimeter based on the d+p elastic scattering after acceleration to 140, 200, and 270MeV. /; ANL=PWIA; \\DATA,1[2; \\EXP,1; RCT=D(3HE,3HE)D; PHQ=ANGL-DSTRN; \\DATA,1; EMT=3HE; THTL=0[1.4DEG; DELTA-DSIGMA/DOMEGA=10%'11'; /* '11' Uncertainties mainly due to beam intensity and target thickness */ \DATA; INC-ENGY-LAB DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'12' (MEV) (MB/SR) (MB/SR) 140 16.3 +-0.1 200 8.56 +-0.03 270 0.97 +-0.08 \END; /* Data taken from Table 1, p024602-2 in reference */ /* '12' Statistical error */ \\EXP,2; RCT=D(3HE,3HE)D; PHQ=TNSR-ANALPW'13'; /* '13' T(20) */ \\DATA,2; EMT=3HE; THTL=0[1.4DEG; DELTA-T20=2%'14'; /* '14' Unncertainty mainly due to beam polarization */ \DATA; INC-ENGY-LAB T20 DELTA-T20'15' (MEV) (NODIM) (NODIM) 140 0.07 +-0.02 200 0.15 +-0.01 270 0.17 +-0.03 \END; /* Data taken from Table 1, p024602-2 in reference */ /* '15' Statistical error */ \\END;